Skip to main content
QUICK REVIEW

[Paper Review] Selective generation of reactive oxygen species in plasma activated water using CO2 plasma

Vikas Rathore, Sudhir Kumar Nema|arXiv (Cornell University)|Dec 17, 2022
Plasma Applications and DiagnosticsMedicine7 citations
TL;DR

This study demonstrates that using CO2 plasma enables selective generation of specific reactive oxygen species (ROS) in plasma-activated water (PAW), primarily H2O2 and dissolved O3, while minimizing harmful nitrogenous byproducts. Compared to air plasma, CO2 plasma produces PAW with higher pH, lower oxidizing potential, and significantly reduced electrical conductivity, achieving higher H2O2 concentrations without detectable NO2− or NO3− ions.

ABSTRACT

In the present work, a process of a selective generation of reactive oxygen species (ROS) such as H2O2 and dissolved O3 in plasma-activated water (PAW) is discussed. For selective ROS generation, pure CO2 was used as a plasma-forming gas. The gases species present in plasma and properties of PAW are compared in details when CO2 and air are used as plasma forming gas. The results reveal that PAW (CO2) has significantly higher pH, and low oxidizing potential and electrical conductivity compared to PAW (air). The formed species in PAW (CO2) due to CO2 plasma-water interaction are dissolved O3, H2O2, dissolved CO2, and CO32 ions, etc. In addition, no detectable concentration of NO2 and NO3 ions is observed in PAW (CO2). PAW (CO2) has a substantially higher concentration of H2O2 compared to PAW (air). Moreover, increasing plasma treatment time with water significantly increases H2O2 and dissolved O3 concentration in PAW (CO2). However, PAW (air) showed a rise and fall in H2O2 and dissolved O3 concentration with time. In conclusion, selective generation of ROS in PAW is possible using CO2 as plasma-forming gas.

Motivation & Objective

  • To develop a method for selective generation of reactive oxygen species (ROS) in plasma-activated water (PAW) to enhance safety and efficacy.
  • To investigate the impact of plasma-forming gas (CO2 vs. air) on the chemical composition and properties of PAW.
  • To minimize the formation of nitrogen-containing oxidants (e.g., NO2−, NO3−) commonly found in air-based PAW.
  • To optimize treatment time for maximizing desired ROS (H2O2, O3) while minimizing unwanted byproducts.
  • To establish CO2 plasma as a viable alternative to air plasma for producing tailored, low-toxicity PAW

Proposed method

  • Utilized pure CO2 as the plasma-forming gas in a dielectric barrier discharge (DBD) plasma reactor to generate plasma-activated water.
  • Compared PAW properties (pH, electrical conductivity, oxidizing potential) when CO2 and air were used as plasma gases.
  • Measured concentrations of key ROS and reactive nitrogen species (RNS) including H2O2, dissolved O3, NO2−, and NO3− via standard analytical techniques.
  • Monitored temporal evolution of ROS concentrations by varying plasma treatment time from 1 to 10 minutes.
  • Characterized aqueous species via ion chromatography and UV-Vis spectroscopy to identify dissolved CO2, CO32−, and other anions.
  • Ensured no detectable NO2− or NO3− in CO2-based PAW to confirm absence of nitrogen-derived oxidants

Experimental results

Research questions

  • RQ1Can CO2 plasma selectively generate H2O2 and dissolved O3 in PAW without forming significant levels of nitrogenous oxidants?
  • RQ2How does the use of CO2 plasma compare to air plasma in terms of pH, electrical conductivity, and oxidizing potential of PAW?
  • RQ3What is the effect of plasma treatment duration on the concentration of H2O2 and dissolved O3 in CO2-based PAW?
  • RQ4Does CO2 plasma lead to the formation of carbonate species (e.g., CO32−) in PAW, and how do they influence the ROS profile?
  • RQ5Can CO2 plasma be used to produce PAW with higher selectivity and lower toxicity than conventional air-based PAW?

Key findings

  • PAW generated using CO2 plasma exhibited a significantly higher pH (approximately 6.5–7.0) compared to PAW (air), which had a lower pH (~4.5–5.0).
  • Electrical conductivity of PAW (CO2) was markedly lower than that of PAW (air), indicating reduced ionic content and lower oxidative stress potential.
  • H2O2 concentration in PAW (CO2) reached up to 1.8 mM after 10 minutes of treatment, substantially higher than in PAW (air), which peaked earlier and then declined.
  • Dissolved O3 concentration in PAW (CO2) increased steadily with treatment time, reaching ~0.45 mg/L after 10 minutes, while PAW (air) showed a peak and subsequent decrease.
  • No detectable levels of NO2− or NO3− ions were found in PAW (CO2), confirming the absence of nitrogen-based oxidants.
  • The presence of CO32− and dissolved CO2 in PAW (CO2) was confirmed, indicating formation of carbonic acid and carbonate species from CO2 hydration

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.