Skip to main content
QUICK REVIEW

[Paper Review] Separating partially coherent light

Paul-Alexis Mor, Anne R. Kroo|arXiv (Cornell University)|Mar 16, 2026
Neural Networks and Reservoir ComputingComputer Science0 citations
TL;DR

The paper demonstrates on-chip coherence tomography that automatically separates partially coherent light into orthogonal coherence modes using self-configuring interferometer layers, revealing eigenvalues and eigenvectors of the coherency matrix.

ABSTRACT

Recent advances in optical imaging and communication increasingly involve high-dimensional, partially coherent light, creating a growing need for scalable tools to measure and manipulate coherence. Here, we demonstrate the automatic separation of spatially partially coherent light into "coherence modes" -- its orthogonal and mutually incoherent components. To make this separation possible, we exploit variational processing in layered self-configuring interferometer architectures in a silicon photonic circuit. This process formally finds and measures the eigenvectors and eigenvalues of the coherency matrix, hence measuring the partially coherent state, while leaving it intact and separated after optimization. Furthermore, we show that mutually incoherent beams, if spatially orthogonal, can be automatically separated even if they are completely overlapped, hence separating unknown laser beams based only on their mutual incoherence. Our experiment finds and separates the two strongest coherence modes starting from a nine-mode sampling of the partially or fully overlapping fields from two independent lasers. The method requires a number of physical components that scales linearly with the rank $r$ of the coherency matrix and operates through a sequence of $r$ in situ gradient-based optimizations enabled by electronic drive frequency multiplexing of interferometer phase shifters. We benchmark its performance against a mixture-based tomographic method, also implemented on chip. These results establish a scalable framework for programmable coherence analysis and control in imaging, communication, and photonic information processing.

Motivation & Objective

  • Motivate scalable measurement and manipulation of partially coherent light for imaging, communication, and photonic processing.
  • Develop a hardware platform that physically separates coherence modes and retrieves the coherency matrix eigenstructure on chip.
  • Implement layer-by-layer variational optimization to perform coherence tomography.
  • Demonstrate automatic separation of mutually incoherent, overlapped beams solely based on coherence properties.
  • Benchmark the approach against mixture tomography and illustrate applications in entropy measurement and coherence-based demultiplexing.

Proposed method

  • Use a two-layer self-configuring Mach-Zehnder interferometer (MZI) network with 9 grating couplers to implement a unitary transformation on the input field.
  • Formulate tomography as a sequence of r variational optimizations that extract coherence modes and eigenvalues of the input coherency matrix.
  • Employ frequency-multiplexed gradient estimation to measure gradients of output power with respect to each phase shifter, enabling in situ gradient descent.
  • Measure coherency matrix elements by observing output powers and interference fringes between layers.
  • Demonstrate coherence-mode separation by physically routing each mode to distinct outputs within a unitary network.
  • Benchmark PCLA against mixture tomography by reconstructing the coherency matrix from two incoherent laser inputs.
  • Show applications: coherence entropy measurement and coherence-based separation of overlapping beams.

Experimental results

Research questions

  • RQ1Can a chip-based interferometric network automatically diagonalize the coherency matrix to reveal coherence modes?
  • RQ2Is it possible to physically separate partially coherent light into orthogonal coherence modes on chip while preserving the state?
  • RQ3How does the PCLA performance compare to traditional mixture tomography in fidelity and eigenvalue accuracy?
  • RQ4Can mutually incoherent, spatially overlapping beams be demultiplexed purely by coherence properties using a self-configuring network?
  • RQ5What operational metrics (entropy, cross-talk) quantify coherence learning and separation on the device?

Key findings

  • The nine-mode device successfully finds and separates the two strongest coherence modes starting from two independent lasers.
  • Eigenvector fidelities are 97.8% (layer 1) and 99.9% (layer 2); eigenvalue estimation errors are 0.29% (layer 1) and 3.11% (layer 2).
  • Two-mode fringe visibility decreases as coherence between outputs is suppressed across the first layer, with no further decrease in the second layer.
  • Cross-talk between separated beams reaches as low as -13.0 dB.
  • Total physical components scale as O(rN), with r the coherency matrix rank and N the mode count; optimization is performed in r layers using gradient-based updates.
  • The approach achieves >98% fidelity against mixture tomography on-chip.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.