[Paper Review] Sequential Diagnosis with Language Models
The paper introduces SDBench, an interactive sequential-diagnosis benchmark using NEJM CPC cases, and MAI-Diagnostic Orchestrator (MAI-DxO) which, by simulating a panel of physician roles, achieves superior accuracy and cost-efficiency across multiple models compared to humans and baseline LMs.
Artificial intelligence holds great promise for expanding access to expert medical knowledge and reasoning. However, most evaluations of language models rely on static vignettes and multiple-choice questions that fail to reflect the complexity and nuance of evidence-based medicine in real-world settings. In clinical practice, physicians iteratively formulate and revise diagnostic hypotheses, adapting each subsequent question and test to what they've just learned, and weigh the evolving evidence before committing to a final diagnosis. To emulate this iterative process, we introduce the Sequential Diagnosis Benchmark, which transforms 304 diagnostically challenging New England Journal of Medicine clinicopathological conference (NEJM-CPC) cases into stepwise diagnostic encounters. A physician or AI begins with a short case abstract and must iteratively request additional details from a gatekeeper model that reveals findings only when explicitly queried. Performance is assessed not just by diagnostic accuracy but also by the cost of physician visits and tests performed. We also present the MAI Diagnostic Orchestrator (MAI-DxO), a model-agnostic orchestrator that simulates a panel of physicians, proposes likely differential diagnoses and strategically selects high-value, cost-effective tests. When paired with OpenAI's o3 model, MAI-DxO achieves 80% diagnostic accuracy--four times higher than the 20% average of generalist physicians. MAI-DxO also reduces diagnostic costs by 20% compared to physicians, and 70% compared to off-the-shelf o3. When configured for maximum accuracy, MAI-DxO achieves 85.5% accuracy. These performance gains with MAI-DxO generalize across models from the OpenAI, Gemini, Claude, Grok, DeepSeek, and Llama families. We highlight how AI systems, when guided to think iteratively and act judiciously, can advance diagnostic precision and cost-effectiveness in clinical care.
Motivation & Objective
- Motivate evaluation of diagnostic AI in realistic, iterative clinical reasoning rather than static vignettes.
- Transform 304 NEJM CPC cases into stepwise encounters with a Gatekeeper and Judge to assess information gathering and decision quality under cost constraints.
- Demonstrate that a model-agnostic orchestrator (MAI-DxO) can improve diagnostic accuracy and reduce costs across multiple language models.
Proposed method
- Develop SDBench by converting 304 NEJM CPC cases into interactive sequential-diagnosis encounters.
- Use a Gatekeeper LM to reveal case findings only when queried, preventing leakage and preserving realism.
- Introduce a Judge agent with a physician-authored rubric to score diagnostic accuracy (Likert scale 1–5) and define correctness as score ≥4.
- Establish cost modeling by assigning fixed visit costs and CPT-based test costs to quantify diagnostic expenses.
- Create MAI-DxO, a multi-physician-panel orchestration framework with five roles (Hypothesis, Test-Chooser, Challenger, Stewardship, Checklist) to steer questioning and testing in a cost-aware manner.
- Evaluate MAI-DxO and baseline LMs versus human physicians on SDBench, using held-out test cases to assess generalization.
Experimental results
Research questions
- RQ1Can AI agents perform sequential diagnosis under realistic information-gathering and cost constraints similar to clinical practice?
- RQ2Does an orchestrated, multi-physician panel improve diagnostic accuracy and reduce costs compared to single models and human physicians?
- RQ3How well do off-the-shelf language models generalize across different model families in sequential diagnostic tasks?
- RQ4What is the impact of incorporating cost-awareness and adversarial/challenge roles on diagnostic quality?
Key findings
- MAI-DxO paired with OpenAI o3 achieves 80% diagnostic accuracy, four times higher than the 20% average for generalist physicians.
- MAI-DxO reduces diagnostic costs by 20% compared to physicians and by 70% compared to off-the-shelf o3.
- When configured for maximum accuracy, MAI-DxO attains 85.5% accuracy.
- MAI-DxO improvements generalize across multiple model families including OpenAI, Gemini, Claude, Grok, DeepSeek, and Llama.
- Off-the-shelf o3 reaches 78.6% accuracy at a cost of $7,850 per case, while physicians average 19.9% accuracy at $2,963 per case.
- MAI-DxO configurations (no budget) yield 81.9% accuracy with cost reductions to $4,735 versus baseline o3, and ensemble variants reach 85.5% accuracy at $7,184.
- MAI-DxO consistently improves accuracy across capable models and notably provides cost-aware improvements for weaker models as well.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.