[Paper Review] Should We Adjust for the Test for Pre-trends in Difference-in-Difference Designs?
This paper demonstrates that standard difference-in-difference (DiD) estimators are biased when inference is conditioned on passing a pre-trend test, especially when true pre-trends exist but are undetected. It proposes two new estimators—median-unbiased and truncated normal confidence intervals—that adjust for pre-test conditioning, restoring valid inference even when parallel trends do not hold in population.
The common practice in difference-in-difference (DiD) designs is to check for parallel trends prior to treatment assignment, yet typical estimation and inference does not account for the fact that this test has occurred. I analyze the properties of the traditional DiD estimator conditional on having passed (i.e. not rejected) the test for parallel pre-trends. When the DiD design is valid and the test for pre-trends confirms it, the typical DiD estimator is unbiased, but traditional standard errors are overly conservative. Additionally, there exists an alternative unbiased estimator that is more efficient than the traditional DiD estimator under parallel trends. However, when in population there is a non-zero pre-trend but we fail to reject the hypothesis of parallel pre-trends, the DiD estimator is generally biased relative to the population DiD coefficient. Moreover, if the trend is monotone, then under reasonable assumptions the bias from conditioning exacerbates the bias relative to the true treatment effect. I propose new estimation and inference procedures that account for the test for parallel trends, and compare their performance to that of the traditional estimator in a Monte Carlo simulation.
Motivation & Objective
- To investigate whether traditional DiD estimators remain unbiased and efficient when inference is conditional on passing a pre-trend test.
- To examine the consequences of conditioning on a failed pre-trend test when true pre-trends exist but are not detected.
- To develop new estimation and inference procedures that account for the pre-test in DiD designs.
- To compare the performance of adjusted estimators against traditional DiD estimators under both valid and invalid parallel trends assumptions.
- To caution researchers against over-relying on pre-trend tests as validation for DiD designs, especially under low test power.
Proposed method
- Proposes a median-unbiased estimator that conditions on the event that the pre-trend test fails to reject the null of parallel trends.
- Introduces a truncated normal confidence interval for the post-treatment coefficient that adjusts for pre-test conditioning.
- Uses Monte Carlo simulations to compare the performance of adjusted and traditional estimators under both correct and incorrect parallel trends assumptions.
- Derives the finite-sample bias of the traditional DiD estimator conditional on not rejecting the pre-trend null, showing it is exacerbated when trends are monotone.
- Derives the optimal unbiased estimator under the assumption of no pre-trends, which is more efficient than the traditional DiD estimator.
- Employs a conditional likelihood framework to construct estimators and confidence intervals that maintain nominal coverage under pre-test conditioning.
Experimental results
Research questions
- RQ1Does the traditional DiD estimator remain unbiased when inference is conditional on having passed a pre-trend test?
- RQ2How does conditioning on a failed pre-trend test affect the bias of the DiD estimator when true pre-trends exist?
- RQ3Can we construct estimators that are unbiased and have valid coverage when conditioning on the outcome of a pre-trend test?
- RQ4How does the power of the pre-trend test affect the reliability of DiD estimates in practice?
- RQ5What is the trade-off between precision and validity when using adjusted estimators that account for pre-test conditioning?
Key findings
- When parallel trends hold in population, the traditional DiD estimator remains unbiased conditional on passing the pre-trend test, but its standard errors are overly conservative.
- An alternative unbiased estimator exists that is more efficient than the traditional DiD estimator under the parallel trends assumption.
- When a non-zero pre-trend exists but is not detected (i.e., the pre-test fails to reject the null), the traditional DiD estimator is generally biased relative to the true treatment effect.
- Under monotone trends, the bias from conditioning on the pre-test result exacerbates the existing bias, making estimates even more misleading than unconditioned ones.
- The proposed truncated normal confidence interval ($CI^{TN}_{eta}$) achieves roughly nominal coverage for the population DiD coefficient across all simulation scenarios.
- The median width of the adjusted confidence intervals is larger than traditional intervals when conditioning on few pre-trend periods, but the gap narrows and can even reverse when conditioning on more than six periods.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.