Skip to main content
QUICK REVIEW

[Paper Review] Simultaneous Detection and Quantification of Retinal Fluid with Deep Learning

Dustin Morley, Hassan Foroosh|arXiv (Cornell University)|Aug 17, 2017
Retinal Imaging and AnalysisMedicine1 references13 citations
TL;DR

This paper presents a deep learning framework that simultaneously detects and quantifies intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) in retinal OCT images using a hybrid ResNet and encoder-decoder architecture. The method employs a novel data augmentation technique called 'myopic warping' and post-processing with graph cut and morphological operations, achieving Dice scores of 0.522, 0.682, and 0.612 for IRF, SRF, and PED respectively, with low volume differences.

ABSTRACT

We propose a new deep learning approach for automatic detection and segmentation of fluid within retinal OCT images. The proposed framework utilizes both ResNet and Encoder-Decoder neural network architectures. When training the network, we apply a novel data augmentation method called myopic warping together with standard rotation-based augmentation to increase the training set size to 45 times the original amount. Finally, the network output is post-processed with an energy minimization algorithm (graph cut) along with a few other knowledge guided morphological operations to finalize the segmentation process. Based on OCT imaging data and its ground truth from the RETOUCH challenge, the proposed system achieves dice indices of 0.522, 0.682, and 0.612, and average absolute volume differences of 0.285, 0.115, and 0.156 mm$^3$ for intaretinal fluid, subretinal fluid, and pigment epithelial detachment respectively.

Motivation & Objective

  • To develop an automated deep learning system for simultaneous detection and quantification of three types of retinal fluid (IRF, SRF, PED) in OCT images.
  • To improve training data diversity and model generalization through a novel data augmentation method, myopic warping, in addition to rotation-based augmentation.
  • To enhance segmentation accuracy by integrating energy minimization (graph cut) and knowledge-guided morphological operations into the post-processing pipeline.
  • To evaluate performance on the RETOUCH challenge dataset despite inconsistencies in the reference standard, particularly for IRF.

Proposed method

  • The framework uses a deep convolutional neural network (CNN) combining ResNet and encoder-decoder architectures to classify each pixel in an OCT slice into one of four classes: IRF, SRF, PED, or background.
  • A novel data augmentation strategy called 'myopic warping' is introduced, simulating retinal curvature by applying an inverse-square force field to warp the image from a central point, with tunable parameters for force strength and center location.
  • Standard rotation augmentation (±8° in 2° increments) is combined with myopic warping to increase the effective training set size by 45×.
  • Zero-padded regions from warping are filled using intensity profiles from background patches, with blocky sampling from a normal distribution to avoid artificial edges.
  • Post-processing applies a 3D graph cut algorithm on yz-plane slices to enforce spatial consistency, using a data cost of zero for the predicted label and a constant for others, with smoothness cost based on a DoG filter.
  • Final segmentation volumes are reconstructed and cropped back to original dimensions after graph cut, with volume calculations performed on the final output.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve simultaneous detection and quantification of multiple retinal fluid types in OCT images without relying on prior retinal layer segmentation?
  • RQ2How effective is the proposed myopic warping augmentation technique in improving model generalization and performance on limited training data?
  • RQ3To what extent does post-processing with graph cut and morphological operations improve segmentation accuracy compared to raw CNN outputs?
  • RQ4How does model performance vary across different OCT scanner types (Zeiss, Heidelberg, Topcon), particularly given inconsistencies in the reference standard?
  • RQ5Is the model's performance robust despite using a reference standard with known inconsistencies, especially for IRF?

Key findings

  • The model achieved a Dice index of 0.522 for intraretinal fluid (IRF), 0.682 for subretinal fluid (SRF), and 0.612 for pigment epithelial detachment (PED) across all devices.
  • The average absolute volume difference (AVD) was 0.285 mm³ for IRF, 0.115 mm³ for SRF, and 0.156 mm³ for PED, indicating high volumetric accuracy.
  • Performance was significantly better on Zeiss and Heidelberg devices than on Topcon for SRF and PED, with lower Dice scores (0.483) and higher AVD (0.222 ± 0.470 mm³) on Topcon for PED.
  • Despite the reference standard's known inconsistencies—especially for IRF—the model showed strong performance, with some cases where its output was more accurate than the ground truth.
  • The method achieved state-of-the-art performance without requiring retinal layer segmentation, suggesting that such preprocessing may not be essential for fluid segmentation.
  • The combination of myopic warping and rotation-based augmentation effectively increased training data diversity, contributing to improved generalization and robustness.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.