Skip to main content
QUICK REVIEW

[Paper Review] Single-Slice-to-3D Reconstruction in Medical Imaging and Natural Objects: A Comparative Benchmark with SAM 3D

Yan Luo, Advaith Ravishankar|arXiv (Cornell University)|Feb 10, 2026
3D Shape Modeling and AnalysisEngineering0 citations
TL;DR

A zero-shot benchmark of five image-to-3D foundation models (including SAM3D) on six medical and two natural datasets shows severe depth ambiguity for single-slice 3D reconstruction, with SAM3D best at capturing global shape, while voxel overlaps remain very low.

ABSTRACT

While three-dimensional imaging is essential for clinical diagnosis, its high cost and long wait times have motivated the use of image-to-3D foundation models to infer volume from two-dimensional modalities. However, because these models are trained on natural images, their learned geometric priors struggle to transfer to inherently planar medical data. A benchmark of five state-of-the-art models (SAM3D, Hunyuan3D-2.1, Direct3D, Hi3DGen, and TripoSG) across six medical and two natural datasets revealed that voxel-based overlap remains uniformly low across all methods due to severe depth ambiguity from single-slice inputs. Despite this fundamental volumetric failure, global distance metrics indicate that SAM3D best captures topological similarity to ground-truth medical shapes, whereas alternative models are prone to oversimplification. Ultimately, these findings quantify the limits of zero-shot single-slice 3D inference, highlighting that reliable medical 3D reconstruction requires domain-specific adaptation and anatomical constraints to overcome complex medical geometries.

Motivation & Objective

  • Assess whether geometric priors learned from natural images transfer to medical imaging for single-slice 3D reconstruction.
  • Quantify depth-ambiguity and voxel-level reconstruction performance across diverse medical and natural datasets.
  • Compare five state-of-the-art image-to-3D foundation models in a zero-shot medical setting.
  • Analyze how anatomical vs. pathological structures influence reconstruction quality and generalization.

Proposed method

  • Extract a midpoint slice from each volumetric medical scan and apply the segmentation mask to create a single masked 2D input.
  • Evaluate five zero-shot models (SAM3D, Hunyuan3D-2.1, Direct3D, Hi3DGen, TripoSG) on the masked 2D input to produce a 3D point cloud.
  • Ground-truth 3D geometry is obtained from segmentation masks via morphological erosion to form a ground-truth point cloud.
  • Align predicted and ground-truth point clouds with ICP after scaling to a unit cube for fair comparison.
  • Compute five metrics: F1@0.01, Voxel IoU, Voxel Dice, Chamfer Distance (CD), and Earth Mover’s Distance (EMD).
  • Contrast performance across medical vs. natural datasets and across coronal vs. axial input slices.

Experimental results

Research questions

  • RQ1Can natural-image depth priors transfer to medical single-slice inputs for 3D reconstruction in zero-shot settings?
  • RQ2What are the limits of voxel-based overlap when reconstructing medical structures from a single 2D slice?
  • RQ3Which model among SAM3D, Hunyuan3D-2.1, Direct3D, Hi3DGen, and TripoSG best preserves global shape in medical single-slice reconstruction?
  • RQ4How do anatomical vs. pathological structures and different anatomical planes affect reconstruction fidelity?

Key findings

  • All models show uniformly low voxel-based overlap (F1, IoU, and Dice scores are generally very low) due to depth-ambiguity from single-slice inputs.
  • SAM3D and Hi3DGen tend to achieve higher voxel-based scores than others, but improvements are small and inconsistent across datasets.
  • Distance metrics (CD and EMD) reveal SAM3D provides better global shape fidelity than competitors, even when voxel overlap is poor.
  • Pathological structures (tumors) yield worse reconstructions than anatomical structures across models.
  • Natural datasets (Google Scanned Objects, Animal3D) generally yield better distance-metric performance than medical datasets, with domain gaps quantified in CD/EMD.
  • Duke C-Spine (a geometrically simpler structure) shows relatively higher voxel-based scores than MSD Lung/Brain/Liver, indicating geometric complexity drives difficulty.
  • Overall, single-slice zero-shot medical 3D reconstruction faces fundamental limits, underscoring the need for domain-adaptation or multi-view approaches.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.