This paper presents GKINT, a specialized computational program for planning and analyzing transient-field g-factor measurements in intermediate-energy radioactive beams, incorporating relativistic kinematics and Coulomb excitation cross-section calculations. It enables precise simulation of angular correlations, Doppler shifts, and transient-field precessions in fast-fragmented beams, with key results demonstrating optimized experimental conditions via figures of merit like $S^2W\sigma$ and $S^2\phi^2N$, validated in NSCL experiment 02020 on $^{38,40}$S.

ABSTRACT

This report describes the computer program GKINT, which was developed to plan, analyze and interpret the first High Velocity Transient Field (HVTF) g-factor measurements on radioactive beams produced as fast fragments. The computer program and these notes were written in September 2004. Minor corrections and updates have been added to these notes since then. The experiment, NSCL experiment number 02020, 'Excited-state configurations in S-38 and S-40 through transient-field g-factor measurements on fast fragments', was performed in October 2004; results have been published in Physical Review Letters 96, 112503 (2006).

Motivation & Objective

  • To develop a computational tool for planning and analyzing transient-field g-factor measurements on fast-fragmented radioactive beams at intermediate energies.
  • To address the limitations of prior codes by incorporating relativistic kinematics and accurate energy loss modeling through thick targets.
  • To enable precise calculation of angular correlations, Doppler shifts, and transient-field precessions for experimental optimization.
  • To provide figures of merit such as $S^2W\sigma$ and $S^2\phi^2N$ to guide experimental design and improve sensitivity.
  • To validate the code through application to NSCL experiment 02020 on $^{38,40}$S, yielding measurable g-factors and excited-state configurations.

Proposed method

  • The program GKINT uses the Runge-Kutta method with Ziegler et al. (1985) stopping power formulations to model energy loss through multi-layered targets with up to 10 layers.
  • It calculates Coulomb excitation cross sections and angular correlation parameters ($a_2$, $a_4$) as functions of energy loss and depth, assuming scattering at the average detection angle.
  • Transient-field precession is computed via time-integrated integrals over energy-dependent magnetic fields, using the relation $\phi(\tau) = -\frac{\mu_N}{\hbar} \int_{T_i}^{T_e} B_{\rm tr}(t) e^{-t/\tau} dt$, transformed into energy-space for numerical stability.
  • The code accounts for finite solid angle of detectors, beam energy loss along the trajectory, and Rutherford ion veto (RIV) effects on angular correlations.
  • It evaluates figures of merit such as $S^2W\sigma$ and $S^2\phi^2N$ to quantify experimental sensitivity, with and without RIV attenuation.
  • The program supports ferromagnetic hosts (Fe, or others via input) and models precession only for $g$-factor measurements in excited states with known lifetimes.

Experimental results

Research questions

  • RQ1How can relativistic kinematics and energy loss in thick, multi-layered targets be accurately modeled for transient-field g-factor measurements in fast-fragmented beams?
  • RQ2What are the optimal beam energies and target configurations to maximize sensitivity in $g$-factor measurements via transient-field precession?
  • RQ3How do Rutherford ion veto (RIV) effects influence the measured angular correlation and precession signal in segmented germanium array (SeGA) detectors?
  • RQ4To what extent do mask configurations on particle detectors reduce background while preserving signal anisotropy and sensitivity?
  • RQ5What figures of merit ($S^2W\sigma$, $S^2\phi^2N$) best predict experimental sensitivity and beam time requirements?

Key findings

  • The GKINT code successfully models energy loss using the Runge-Kutta method with Ziegler stopping powers, achieving convergence within a few keV for targets up to several hundred mg/cm² using ~300 steps.
  • For a 1540 MeV $^{38}$S beam on a 355 mg/cm² Au + 100 mg/cm² Fe target, the Rutherford rate was reduced from 1000 Hz to 36 Hz with a mask at $\theta_p^\text{max} = 5.5^\circ$, while $S^2W\sigma$ increased to 1260.
  • The figure of merit $S^2W\sigma$ reached a maximum of 1260 at $\theta_p^\text{max} = 5.5^\circ$ with a mask, indicating optimal sensitivity for beam time allocation.
  • The program accurately reproduces the $S^2\phi^2N$ figure of merit, which scales with $(\sigma_{\Delta\theta}/\Delta\theta)^2$ and accounts for precession decay beyond the target.
  • The code's predictions were validated in NSCL experiment 02020, where $g$-factor measurements on $^{38,40}$S revealed excited-state configurations consistent with shell-model predictions.
  • The inclusion of RIV attenuation in angular correlation calculations reduced signal anisotropy, but the unattenuated correlations served as a useful reference for experimental design.

Read this paper