Skip to main content
QUICK REVIEW

[Paper Review] Spectral Data Augmentation Techniques to quantify Lung Pathology from CT-images

Subhradeep Kayal, Florian Dubost|arXiv (Cornell University)|Apr 24, 2020
Radiomics and Machine Learning in Medical ImagingMedicine18 references5 citations
TL;DR

This paper proposes spectral data augmentation using Discrete Cosine Transform (DCT) and Discrete Wavelet Transform (DWT) to improve lung pathology segmentation in CT scans. By adding noise to spectral components, the method generates synthetic images that simulate variations in scan protocols, significantly boosting performance—especially when combined with existing augmentation, achieving a 44.1% relative improvement in F1-score for the diseased class over simple replication.

ABSTRACT

Data augmentation is of paramount importance in biomedical image processing tasks, characterized by inadequate amounts of labelled data, to best use all of the data that is present. In-use techniques range from intensity transformations and elastic deformations, to linearly combining existing data points to make new ones. In this work, we propose the use of spectral techniques for data augmentation, using the discrete cosine and wavelet transforms. We empirically evaluate our approaches on a CT texture analysis task to detect abnormal lung-tissue in patients with cystic fibrosis. Empirical experiments show that the proposed spectral methods perform favourably as compared to the existing methods. When used in combination with existing methods, our proposed approach can increase the relative minor class segmentation performance by 44.1% over a simple replication baseline.

Motivation & Objective

  • Address class imbalance and limited labeled data in biomedical image segmentation, particularly for rare lung pathologies like cystic fibrosis.
  • Improve generalization of deep learning models in low-data regimes by generating diverse, realistic synthetic training samples.
  • Explore frequency-domain data augmentation as a complementary approach to spatial-domain methods.
  • Evaluate the effectiveness of spectral transforms (DCT and DWT) in enhancing segmentation performance on lung CT images.
  • Determine the optimal noise level and combination strategy for spectral augmentation in clinical imaging tasks.

Proposed method

  • Apply Discrete Cosine Transform (DCT) to decompose CT images into frequency components, then add scale-proportional Gaussian noise to the coefficients to generate synthetic images.
  • Use Discrete Wavelet Transform (DWT) to decompose images into approximation and detail coefficients at multiple scales, enabling localized frequency analysis.
  • Reconstruct synthetic images via inverse DCT or inverse DWT after corrupting spectral coefficients with noise proportional to their magnitude.
  • Control noise intensity via a parameter η, which sets the maximum noise level relative to each coefficient’s value, with R values linearly sampled between 0 and η.
  • Combine spectral augmentation with standard data augmentation techniques (e.g., affine transformations, elastic deformations, intensity shifts) to enhance model robustness.
  • Train a U-Net model on augmented data and apply morphological hole-filling to refine pixel-wise segmentation outputs.

Experimental results

Research questions

  • RQ1Can spectral data augmentation using DCT and DWT improve segmentation performance in low-resource biomedical imaging settings?
  • RQ2How does the performance of spectral augmentation compare to conventional spatial-domain augmentation techniques like elastic deformations and affine transforms?
  • RQ3What is the optimal level of noise (η) in spectral components for generating effective synthetic training samples?
  • RQ4Does combining spectral augmentation with existing data augmentation methods yield synergistic improvements in model generalization?
  • RQ5Can spectral augmentation help reduce overfitting and improve F1-score for the minority (diseased) class in lung tissue segmentation?

Key findings

  • The DWT-based spectral augmentation method with η = 0.5% achieved the highest F1-score (0.34581) on the test set, outperforming all other individual augmentation techniques.
  • When combined with affine and elastic deformations, DWT@0.5% augmentation increased the F1-score for the diseased class by 44.1% compared to simple data replication.
  • The performance of spectral methods decreased with higher noise levels (η), indicating a trade-off between diversity and signal fidelity.
  • DWT-based augmentation performed better than DCT-based augmentation, likely due to its ability to capture localized frequency information.
  • Combining spectral augmentation with standard methods (affine, elastic, intensity) yielded the best overall performance, outperforming even the second-best individual method by 10.3% in F1-score.
  • The results demonstrate that spectral augmentation provides complementary information to spatial-domain methods, enhancing model robustness to variations in scan protocols.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.