Skip to main content
QUICK REVIEW

[Paper Review] Speech recognition for medical conversations

Chung‐Cheng Chiu, Anshuman Tripathi|arXiv (Cornell University)|Nov 20, 2017
Topic ModelingComputer Science12 references11 citations
TL;DR

This paper presents an end-to-end speech recognition system for transcribing doctor-patient medical conversations using both Connectionist Temporal Classification (CTC) and Listen Attend and Spell (LAS) models. Trained on 14,000 hours of anonymized clinical speech, the LAS model achieved a 18.3% word error rate and showed strong robustness to noisy transcripts, outperforming CTC-based models that required extensive data cleaning and language model adaptation to reach 20.1% WER.

ABSTRACT

In this work we explored building automatic speech recognition models for transcribing doctor patient conversation. We collected a large scale dataset of clinical conversations ($14,000$ hr), designed the task to represent the real word scenario, and explored several alignment approaches to iteratively improve data quality. We explored both CTC and LAS systems for building speech recognition models. The LAS was more resilient to noisy data and CTC required more data clean up. A detailed analysis is provided for understanding the performance for clinical tasks. Our analysis showed the speech recognition models performed well on important medical utterances, while errors occurred in causal conversations. Overall we believe the resulting models can provide reasonable quality in practice.

Motivation & Objective

  • To develop a scalable automatic speech recognition (ASR) system for transcribing real-world doctor-patient medical conversations.
  • To address the challenges of noisy, multi-speaker, long-form clinical conversations with overlapping speech, variable audio quality, and domain-specific vocabulary.
  • To compare the effectiveness of CTC-based and end-to-end LAS models in handling noisy data and achieving high accuracy on clinically relevant content.
  • To evaluate model performance on critical medical phrases and drug name recognition, essential for clinical documentation.
  • To demonstrate that end-to-end models can reduce dependency on manual data cleaning and external language models compared to traditional CTC approaches.

Proposed method

  • Built a CTC-based ASR system using context-dependent phoneme outputs with connectionist temporal classification loss and an FST-based decoder.
  • Developed a bidirectional and unidirectional CTC model, both combined with a domain-matched n-gram language model and pronunciation dictionaries.
  • Implemented an end-to-end LAS model with an encoder-decoder architecture using self-attention mechanisms to generate grapheme-level transcriptions.
  • Applied a two-stage data segmentation and cleaning strategy to improve alignment and transcript quality in the 14,000-hour corpus.
  • Used scheduled sampling and multi-headed attention in the LAS model to improve robustness and reduce error rates.
  • Conducted extensive ablation studies, including MTR (model tuning and retraining) and EMBR (error modeling and backpropagation refinement), to optimize performance.

Experimental results

Research questions

  • RQ1How do CTC and LAS models compare in performance on noisy, real-world medical conversation data with overlapping speech and variable audio quality?
  • RQ2To what extent does data quality impact CTC-based models compared to end-to-end LAS models?
  • RQ3Can end-to-end LAS models achieve high accuracy on clinically critical phrases without requiring external language models?
  • RQ4How effective are the models at recognizing key medical terms, particularly drug names, in spoken clinical dialogues?
  • RQ5What is the contribution of data cleaning and language model adaptation to the performance of CTC-based systems versus LAS models?

Key findings

  • The LAS model achieved a word error rate (WER) of 18.3%, outperforming the CTC model, which reached 20.1% WER after extensive data cleaning and language model integration.
  • The LAS model demonstrated resilience to noisy transcripts and did not require an external language model, while CTC models required significant data preprocessing and a matched language model to achieve acceptable performance.
  • On clinically important phrases, the CTC model achieved 92% precision and 86% recall with bidirectional models, indicating strong performance on key medical content.
  • The LAS model achieved 98.2% recall in recognizing treatment-related drug names, highlighting its effectiveness in capturing critical medical terminology.
  • Error analysis showed that CTC models struggled most with short speaker turns (<1 second), overlapping speech, and disfluencies, often deleting or misrecording casual conversational content.
  • The LAS model’s primary errors were related to acoustic modeling of common words (e.g., 'Don’t pay a penny' → 'Don’t byetta penny'), indicating that it learns language patterns effectively but can confuse similar-sounding terms.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.