Skip to main content
QUICK REVIEW

[Paper Review] Status and Sensitivity Projections for the XENON100 Dark Matter Experiment

E. Aprile, L. Baudis|arXiv (Cornell University)|Feb 24, 2009
Dark Matter and Cosmic PhenomenaPhysics and Astronomy4 references19 citations
TL;DR

This paper presents the design, commissioning status, and sensitivity projections for the XENON100 dark matter experiment, a 100 kg-scale two-phase xenon time projection chamber operating at the Gran Sasso Underground Laboratory. By achieving a background-free exposure of 6,000 kg-days, XENON100 projected a spin-independent WIMP-nucleon cross-section sensitivity of $2 \times 10^{-45}$ cm² by 2009, with a planned upgrade to $2 \times 10^{-46}$ cm² by 2012 through improved background suppression and increased target mass.

ABSTRACT

The XENON experimental program aims to detect cold dark matter particles via their elastic collisions with xenon nuclei in two-phase time projection chambers (TPCs). We are currently testing a new TPC at the 100 kg scale, XENON100. This new, ultra-low background detector, has a total of 170 kg of xenon (65 kg in the target region and 105 kg in the active shield). It has been installed at the Gran Sasso Underground Laboratory and is currently in commissioning phase. We review the design and performance of the detector and its associated systems, present status, preliminary calibration results, background prediction and projected sensitivity. With a 6000 kg-day background-free exposure, XENON100 will reach a sensitivity to spin-independent WIMP-nucleon cross section of 2e-45 cm2 by the end of 2009. We also discuss our plan to upgrade the XENON100 experiment to improve the sensitivity by another order of magnitude by 2012.

Motivation & Objective

  • To demonstrate the feasibility of a high-sensitivity, low-background dark matter search using a two-phase xenon time projection chamber (XeTPC) at the 100 kg scale.
  • To achieve background-free operation in a fiducialized target volume through active background discrimination using S2/S1 ratio and active veto systems.
  • To project the experimental sensitivity of XENON100 to weakly interacting massive particles (WIMPs) via spin-independent and spin-dependent scattering cross sections.
  • To outline a path for upgrading XENON100 to improve sensitivity by an order of magnitude by 2012 through reduced backgrounds and increased target mass.
  • To validate the detector's performance and background suppression capabilities using preliminary calibration and shielding data.

Proposed method

  • Utilizes a two-phase xenon time projection chamber (XeTPC) with 65 kg of liquid xenon (LXe) in a 15 cm radius, 30 cm high PTFE-walled volume, instrumented with 178 low-radioactivity PMTs (98 in gas, 80 in liquid) for simultaneous detection of S1 (primary scintillation) and S2 (proportional scintillation) signals.
  • Employs a 1 kV/cm drift field across the 30 cm LXe gap and a 13 kV/cm field in a 5 mm gas proportional scintillation region to amplify ionization signals, enabling high electron lifetime and efficient charge collection.
  • Applies fiducialization to isolate the inner 50 kg (later 30 kg or 100 kg) of the target from surface and material backgrounds, enhancing signal purity.
  • Uses a 105 kg active LXe veto in the surrounding shield to detect and reject external background events via coincidence with the main detector.
  • Implements a continuous xenon gas circulation system with high-temperature metal getters (SAES) to purify Xe to <1 ppb O₂ equivalent, ensuring long electron drift lengths (>4 m) and high VUV photon transmission.
  • Applies a 98% efficient muon veto to suppress neutron backgrounds from muon-induced spallation in the shield and rock, reducing single scatter nuclear recoil (NR) rates.

Experimental results

Research questions

  • RQ1What is the projected sensitivity of the XENON100 experiment to spin-independent WIMP-nucleon scattering cross sections with a 6,000 kg-day background-free exposure?
  • RQ2How effective is the S2/S1 ratio in discriminating nuclear recoils (WIMP signals) from electron recoils (dominant background) in liquid xenon?
  • RQ3What are the dominant background sources in the XENON100 detector, and how can they be suppressed through shielding, fiducialization, and active veto systems?
  • RQ4What improvements are required to upgrade XENON100 to achieve a sensitivity of $2 \times 10^{-46}$ cm² by 2012?
  • RQ5To what extent can the detector’s background budget be reduced through material selection, low-radioactivity components, and optimized cryogenic and electrical systems?

Key findings

  • With a 6,000 kg-day background-free exposure, XENON100 projected a spin-independent WIMP-nucleon cross-section sensitivity of $2 \times 10^{-45}$ cm² for a 100 GeV/c² WIMP by the end of 2009.
  • The current XENON100 experiment achieved a projected sensitivity of $6 \times 10^{-45}$ cm² in a 50 kg fiducial mass over 40 live days, improving to $2 \times 10^{-45}$ cm² after 6 months of data-taking in a 30 kg fiducial volume.
  • The upgraded XENON100 experiment, with a 100 kg fiducial target and further background suppression, projected a sensitivity of $2 \times 10^{-46}$ cm², representing a factor of ten improvement over the baseline XENON100.
  • The total background rate in the WIMP search region (2–12 keVee or 4.5–26.9 keVnr) was estimated at <9.8 events/kg/day for electron recoils (ER) and <55.7 events/kg/day for nuclear recoils (NR), with the dominant contributions from ⁸⁵Kr, ²²²Rn, and muon-induced neutrons.
  • The S2/S1 ratio discrimination achieved 99.5–99.9% efficiency in rejecting electron recoil backgrounds, enabling effective suppression of γ and β backgrounds.
  • The total background in the 100 kg fiducial target of the upgraded XENON100 was estimated at <7.3 events/year for NR and <0.35 events/year for ER, with a 98% muon veto reducing muon-induced neutron backgrounds to <3.7 events/year.