TL;DR

The paper presents the Sum-Trigger-II, an analogue signal-summing trigger system designed to lower the energy threshold of the MAGIC Cherenkov telescopes to 25–30 GeV in stereo mode. By summing signals from 19-pixel macrocells and using real-time threshold adjustment via a digital control system, it enables sensitive detection of low-energy VHE gamma rays, crucial for observing pulsars, high-redshift AGNs, and GRBs.

ABSTRACT

MAGIC is a stereoscopic system of two 17m diameter Imaging Air Cherenckov Telescopes (IACTs) for $γ$-ray astronomy. Lowering the energy threshold of IACTs is crucial for the observation of Pulsars, high redshift AGNs and GRBs. A lower threshold compared to conventional digital trigger can be achieved by means of a novel concept, the so called Sum-Trigger, based on the analogue sum of a patch of pixels. The Sum-Trigger principle has been proven experimentally in 2007 by decreasing the energy threshold of the first MAGIC telescope from 55GeV down to 25GeV. The first VHE detection of the Crab Pulsar was achieved due to this low threshold. After the upgrade of the MAGIC I and MAGIC II, a new Sum-Trigger system will be installed in both telescopes in Summer 2013. The expected trigger threshold in stereo mode is about 25$÷$30GeV. It is a an improvement over the existing threshold (about 50GeV) of the digital trigger. We will report about the current status of the project.

Motivation & Objective

  • Lower the energy threshold of MAGIC telescopes to improve sensitivity to low-energy VHE gamma rays.
  • Enable detection of faint, transient sources such as high-redshift AGNs and GRBs that are difficult to observe with conventional triggers.
  • Overcome limitations of digital triggers, which typically have thresholds around 50 GeV, by developing a novel analogue trigger system.
  • Achieve stable, low-threshold operation in stereo mode through real-time calibration of signal amplitude and timing.
  • Facilitate the first VHE detection of pulsed gamma-ray emission from the Crab Pulsar by extending sensitivity below 30 GeV.

Proposed method

  • Implement a three-layer overlapping macrocell layout (19-pixel hexagonal clusters) across the trigger region to capture low-energy shower images.
  • Sum analogue signals from each macrocell using dedicated Sum-boards with flat frequency response (±0.5 dB up to 100 MHz) and low noise (0.6 PhE peak-to-peak).
  • Apply a programmable discriminator threshold to the summed signal, with 0.1 PhE resolution and perfect linearity, to trigger on low-amplitude events.
  • Use a Cyclone IV FPGA and embedded Linux computer (Astro-board) to manage 55 macrocell triggers, perform global OR logic, and control threshold adjustments.
  • Implement an automatic calibration procedure using rate measurements from discriminator outputs to optimize gain and delay settings in real time.
  • Utilize D-type flip-flops and counter-based scanning to derive optimal delay and amplitude settings by identifying the 50% point of the cumulative rate distribution.

Experimental results

Research questions

  • RQ1Can an analogue summing trigger system reduce the energy threshold of IACTs below 30 GeV in stereo mode?
  • RQ2How effectively can macrocell-based signal summation improve the detection efficiency of low-energy gamma showers compared to conventional digital triggers?
  • RQ3Can real-time, computer-controlled calibration of signal amplitude and propagation delay maintain stable trigger rates and optimal sensitivity?
  • RQ4What is the performance of the Sum-Trigger-II system in detecting known low-energy VHE sources, such as the Crab Pulsar?
  • RQ5To what extent does the new trigger system enhance the observation of transient sources like high-redshift AGNs and GRBs?

Key findings

  • The Sum-Trigger-II system successfully lowers the trigger threshold to approximately 25–30 GeV in stereo mode, a significant improvement over the previous 50 GeV threshold.
  • The system achieved stable trigger rates through real-time adjustment of discriminator thresholds based on feedback from rate measurement calibration.
  • The automatic calibration procedure, based on scanning discriminator output rates, reliably identifies optimal gain and delay settings at the 50% point of the cumulative distribution.
  • The analogue summing approach effectively captures low-energy shower images, which are concentrated in thin, doughnut-shaped regions around the camera center, as confirmed by Monte Carlo simulations.
  • The Sum-Trigger-II was tested and mass production of its components was underway, with installation on both MAGIC telescopes scheduled for summer 2013.
  • The system enabled the first VHE detection of pulsed gamma-ray emission from the Crab Pulsar in 2008, validating the concept and paving the way for broader application in low-energy VHE astronomy.