[Paper Review] Structural Identifiability Analysis of Fractional Order Models with Applications in Battery Systems
This paper proposes a coefficient mapping-based method for structural identifiability analysis of fractional-order systems, specifically applied to battery fractional-order equivalent circuit models (FO-ECMs). The method enables time-domain analysis and proves that FO-ECMs with finite CPEs are structurally identifiable, with the single-CPE model being structurally globally identifiable, resolving key challenges in parameter estimation for battery modeling.
This paper presents a method for structural identifiability analysis of fractional order systems by using the coefficient mapping concept to determine whether the model parameters can uniquely be identified from input-output data. The proposed method is applicable to general non-commensurate fractional order models. Examples are chosen from battery fractional order equivalent circuit models (FO-ECMs). The battery FO-ECM consists of a series of parallel resistors and constant phase elements (CPEs) with fractional derivatives appearing in the CPEs. The FO-ECM is non-commensurate if more than one CPE is considered in the model. Currently, estimation of battery FO-ECMs is performed mainly by fitting in the frequency domain, requiring costly electrochemical impedance spectroscopy equipment. This paper aims to analyse the structural identifiability of battery FO-ECMs directly in the time domain. It is shown that FO-ECMs with finite numbers of CPEs are structurally identifiable. In particular, the FO-ECM with a single CPE is structurally globally identifiable.
Motivation & Objective
- To address the lack of systematic structural identifiability analysis methods for non-commensurate fractional-order systems in the time domain.
- To determine whether parameters in battery fractional-order equivalent circuit models (FO-ECMs) can be uniquely identified from input-output data.
- To overcome limitations of frequency-domain fitting, which requires costly EIS equipment and may introduce bias.
- To establish a general framework applicable to both commensurate and non-commensurate fractional-order models.
- To validate the identifiability of FO-ECMs with finite numbers of constant phase elements (CPEs) using a coefficient map-based approach.
Proposed method
- The method employs a coefficient mapping concept to transform the input-output behavior of fractional-order systems into a set of polynomial coefficients.
- It derives state-space and transfer function representations for SISO fractional-order systems using Caputo derivatives with arbitrary orders.
- The coefficient map is constructed from the Taylor series expansion of the transfer function, mapping model parameters to observable coefficients.
- The identifiability is assessed by analyzing the injectivity of the coefficient map, requiring solution of a system of nonlinear coupled equations.
- For the single-CPE FO-ECM, the method proves global identifiability by showing the coefficient map is finitely many-to-one with only two real solutions.
- The approach is extended to multi-CPE models by solving a system of equations equal in number to the number of CPEs, ensuring structural identifiability.
Experimental results
Research questions
- RQ1Can structural identifiability be determined for non-commensurate fractional-order systems directly in the time domain?
- RQ2Are battery FO-ECMs with multiple constant phase elements (CPEs) structurally identifiable from input-output data?
- RQ3Does the coefficient mapping method enable unique parameter recovery for fractional-order models without relying on frequency-domain data?
- RQ4Is the single-CPE FO-ECM structurally globally identifiable?
- RQ5What is the relationship between the number of CPEs and the solvability of the identifiability equations?
Key findings
- The proposed coefficient mapping method successfully determines structural identifiability for general non-commensurate fractional-order systems in the time domain.
- Battery FO-ECMs with a finite number of CPEs are structurally identifiable, meaning their parameters can be uniquely determined from rich input-output data.
- The single-CPE FO-ECM is proven to be structurally globally identifiable, with only two real solutions to the identifiability equations, which are permutations of each other.
- The method enables direct time-domain parameter estimation, avoiding the need for costly electrochemical impedance spectroscopy (EIS) and reducing potential bias from frequency-domain conversion.
- The coefficient map is finitely many-to-one, confirming that parameter recovery is possible under ideal data conditions.
- The parameter recovery process is systematic: R∞ is estimated directly from f2T+2, followed by recursive backward computation of aij, bi, Ci, Ri, and αi from the coefficients.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.