Skip to main content
QUICK REVIEW

[Paper Review] Study of uncertainty and repeatability in structured-light 3D scanners

María Eugenia Polo García, Aurora Cuartero|arXiv (Cornell University)|Oct 29, 2019
3D Surveying and Cultural HeritageEarth and Planetary Sciences18 references7 citations
TL;DR

This study evaluates the uncertainty and repeatability of two structured-light 3D scanners (Go!SCAN 20TM and Go!SCAN 50TM) by scanning steel gauge blocks at varying resolutions. It identifies a systematic error comparable to the nominal accuracy and finds a global uncertainty of approximately 0.05 mm, with no significant difference between models, leading to a proposed scanning strategy based on resolution-dependent performance.

ABSTRACT

Structured-light 3D scanners create 3D models with high accuracy, but controlling the accuracy and repeatability of the scanner is essential. The objective of this paper is to analyze the repeatability and accuracy of two structured-light 3D scanners (Go!SCAN 20TM and Go!SCAN 50TM). The method used scans steel gauge blocks several times with different resolutions to analyze the scanned data and to test the correlation between uncertainty, resolution, and scanner model. The primary results include: 1) a systematic error of magnitude similar to nominal accuracy exists and must be corrected and 2) the global uncertainty is approximately 0.05 mm without significant differences between the two scanner models. A strategy for scanning is proposed based on the results at different resolutions.

Motivation & Objective

  • To assess the repeatability and accuracy of structured-light 3D scanners under controlled conditions.
  • To identify systematic errors affecting measurement reliability in commercial 3D scanners.
  • To evaluate the influence of scanning resolution on uncertainty and data consistency.
  • To compare performance between two scanner models (Go!SCAN 20TM and Go!SCAN 50TM) in terms of uncertainty and repeatability.
  • To develop a practical scanning strategy based on resolution-dependent performance and uncertainty characteristics.

Proposed method

  • Scanning of calibrated steel gauge blocks multiple times to collect repeated measurements under identical conditions.
  • Varying scanning resolution across multiple test sessions to analyze resolution-dependent uncertainty.
  • Using statistical analysis to quantify repeatability and identify systematic deviations from true dimensions.
  • Comparing measured data against known gauge block dimensions to assess accuracy and bias.
  • Calculating global uncertainty as a function of resolution and scanner model using standard deviation and bias estimation.
  • Proposing a scanning strategy based on resolution and observed uncertainty trends.

Experimental results

Research questions

  • RQ1What is the level of uncertainty in structured-light 3D scanners across different resolutions and scanner models?
  • RQ2Does a systematic error exist in the measurements, and how does it compare to the nominal accuracy?
  • RQ3Is there a significant difference in uncertainty between the Go!SCAN 20TM and Go!SCAN 50TM models?
  • RQ4How does scanning resolution affect the repeatability and accuracy of 3D scans?
  • RQ5Can a practical scanning strategy be developed based on resolution and uncertainty behavior?

Key findings

  • A systematic error was identified with a magnitude comparable to the nominal accuracy of the scanners, indicating a need for correction in measurement results.
  • The global uncertainty across all tested conditions was approximately 0.05 mm, with no statistically significant difference between the Go!SCAN 20TM and Go!SCAN 50TM models.
  • Uncertainty remained stable across different resolutions, suggesting consistent performance regardless of resolution settings.
  • Repeatability was high across multiple scans, indicating reliable performance under controlled conditions.
  • The results support the development of a resolution-based scanning strategy to optimize measurement accuracy and uncertainty.
  • The study confirms that both scanners exhibit similar uncertainty levels, making model choice less critical for accuracy when systematic errors are corrected.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.