[Paper Review] Sub-megahertz homogeneous linewidth for Er in Si via in situ single photon detection
This study achieves sub-megahertz homogeneous linewidths (down to 0.75 MHz) for erbium ions in silicon using in situ single photon detection, bypassing nanofabrication. By combining resonant photoluminescence excitation with superconducting single-photon detectors, the authors resolve 70 previously unobserved Er:Si resonances, with optical lifetimes up to 1.5 ms and inhomogeneous broadening below 400 MHz, establishing Er:Si as a leading candidate for quantum memory and communication applications.
We studied the optical properties of a resonantly excited trivalent Er ensemble in Si accessed via in situ single photon detection. A novel approach which avoids nanofabrication on the sample is introduced, resulting in a highly efficient detection of 70 excitation frequencies, of which 63 resonances have not been observed in literature. The center frequencies and optical lifetimes of all resonances have been extracted, showing that 5% of the resonances are within 1 GHz of our electrically detected resonances and that the optical lifetimes range from 0.5 ms up to 1.5 ms. We observed inhomogeneous broadening of less than 400 MHz and an upper bound on the homogeneous linewidth of 1.4 MHz and 0.75 MHz for two separate resonances, which is a reduction of more than an order of magnitude observed to date. These narrow optical transition properties show that Er in Si is an excellent candidate for future quantum information and communication applications.
Motivation & Objective
- To characterize the optical properties of trivalent erbium ions in silicon with high spectral resolution.
- To overcome limitations of prior EPR, PL, and PLE techniques in resolving individual Er:Si sites.
- To achieve sub-megahertz homogeneous linewidths essential for quantum memory and communication applications.
- To develop a scalable, in situ method for probing rare earth ion transitions without requiring nanofabrication on the sample.
- To measure optical lifetimes and inhomogeneous broadening across a broad range of resonances in Er:Si.
Proposed method
- Employed in situ resonant photoluminescence excitation (PLE) spectroscopy using a superconducting single-photon detector (SSPD) for high sensitivity.
- Used a 300 mK cryogenic setup to minimize thermal broadening and enhance signal-to-noise ratio (SNR).
- Performed transient spectral hole burning on selected resonances to extract homogeneous linewidths.
- Applied acousto-optic modulators (AOM) and electro-optic modulators (EOM) for precise laser frequency control and excitation.
- Avoided nanofabrication by directly probing the sample in situ, enabling rapid characterization of multiple resonances.
- Measured excitation amplitudes, linewidths, and lifetimes from photon count rates and decay dynamics.
Experimental results
Research questions
- RQ1What is the homogeneous linewidth of individual Er:Si resonances in silicon, and can it be reduced below 1 MHz?
- RQ2How many previously unobserved Er:Si resonances can be resolved using in situ single-photon detection?
- RQ3What are the optical lifetimes of Er:Si transitions, and how do they correlate with resonance frequency?
- RQ4To what extent does inhomogeneous broadening limit the coherence of Er:Si optical transitions?
- RQ5Can a non-invasive, in situ detection method achieve sub-MHz linewidths without requiring sample-specific nanofabrication?
Key findings
- The homogeneous linewidth for a resonance at 1538.685 nm was measured at 0.75 MHz, and for 1532.254 nm at 1.4 MHz, representing a more than tenfold reduction over previous results.
- The inhomogeneous broadening of the Er:Si ensemble was found to be less than 400 MHz, indicating high spectral purity.
- Optical lifetimes ranged from 0.5 ms to 1.5 ms, with several resonances showing lifetimes exceeding 1 ms.
- A total of 70 distinct resonances were identified, of which 63 had not been previously observed in EPR, PL, or PLE studies.
- The signal-to-noise ratio (SNR) was sufficient to resolve narrow features across a 1530–1540 nm spectral range with high fidelity.
- The method enabled rapid, non-destructive characterization of multiple resonances without sample-specific fabrication, demonstrating scalability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.