[Paper Review] Sub MeV Particles Detection and Identification in the MUNU detector ((1)ISN, IN2P3/CNRS-UJF, Grenoble, France, (2)Institut de Physique, Neuchâtel, Switzerland, (3) INFN, Padova Italy, (4) Physik-Institut, Zürich, Switzerland)
The MUNU detector, a 1 m³ gas time projection chamber (TPC) filled with CF₄ at 3 bar and surrounded by a 10 m³ liquid scintillator vessel, enables sub-MeV particle detection and identification via combined measurement of ionization charge and scintillation light. It achieves a 3D reconstruction of electron tracks from neutrino-electron scattering, demonstrating the first successful reconstruction of a ~1 MeV photopeak (835 keV from ⁵⁴Mn) using Compton scattering in a gaseous TPC, with energy resolution of 220 keV FWHM and angular resolution of 39.7° ± 2.2°.
We report on the performance of a 1 m$^{3}$ TPC filled with CF$_{4}$ at 3 bar, immersed in liquid scintillator and viewed by photomultipliers. Particle detection, event identification and localization achieved by measuring both the current signal and the scintillation light are presented. Particular features of $α$ particle detection are also discussed. Finally, the ${54}$Mn photopeak, reconstructed from the Compton scattering and recoil angle is shown.
Motivation & Objective
- To detect and identify low-energy electrons from electron antineutrino scattering near a nuclear reactor.
- To develop a gaseous TPC capable of sub-MeV energy resolution and precise 3D track reconstruction for neutrino physics.
- To suppress background from cosmic rays and Compton scattering using an external liquid scintillator veto.
- To enable spectroscopy of low-energy solar neutrinos, such as ⁷Be (862 keV) and pp (420 keV) neutrinos.
- To validate the feasibility of using gas TPCs with dual readout (charge and light) for future low-background neutrino experiments.
Proposed method
- A 1 m³ TPC filled with CF₄ gas at 3 bar uses a cathode, grid, anode, and x-y strip readout for ionization charge collection.
- The TPC is enclosed in a 10 m³ liquid scintillator vessel viewed by photomultipliers to detect scintillation light and veto cosmic and Compton events.
- Primary scintillation light from alpha particles and amplified light from electron avalanches at the anode are used to determine track position and topology with high precision.
- A Fourier-based noise reduction technique is applied to x- and y-strip signals to improve spatial resolution despite long cables and high electronic noise.
- 3D event reconstruction is achieved by combining time-of-flight from scintillator light with 2D track projection in the TPC, enabling full vertex and incident gamma direction determination.
- Energy and angular resolutions are evaluated using ⁵⁴Mn Compton scattering data, with track reconstruction performed via automated image processing.
Experimental results
Research questions
- RQ1Can a gaseous TPC with dual readout (charge and scintillation light) achieve sub-MeV energy resolution for low-energy electron recoils?
- RQ2Can the combination of TPC tracking and external scintillator veto effectively suppress cosmic-ray and Compton backgrounds in low-energy neutrino experiments?
- RQ3Is it feasible to reconstruct the incident gamma energy from Compton scattering in a gas TPC using only the recoil electron track and scintillation light?
- RQ4What is the achievable energy and angular resolution for electron recoils below 1 MeV in a CF₄-based TPC at 3 bar pressure?
- RQ5Can this detector concept be extended to detect solar neutrinos, particularly the ⁷Be and pp neutrino peaks?
Key findings
- The MUNU detector achieves a 3D reconstruction of electron tracks from neutrino-electron scattering with a recoil electron energy threshold of 300 keV.
- The reconstructed 835 keV photopeak from ⁵⁴Mn decay has a full width at half maximum (FWHM) of 220 keV, demonstrating the first successful photopeak reconstruction in a gaseous TPC using Compton scattering.
- The angular resolution for Compton scattering events above 300 keV is 39.7° ± 2.2°, indicating good directional sensitivity for incident gamma rays.
- The energy resolution at 640 keV is 10.1%, consistent with simulations, and follows an empirical E⁰.⁷ dependence rather than a simple √E law.
- Primary scintillation light from alpha particles is well resolved, enabling unambiguous particle identification and absolute axial position determination along the drift direction.
- The detector’s dual readout (charge and light) significantly improves event topology characterization and background suppression, especially for cosmic rays and Compton events.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.