[Paper Review] Sub-mm and X-ray background: two unrelated phenomena?
This study investigates whether submillimeter (sub-mm) and hard X-ray (2–10 keV) backgrounds arise from the same astrophysical population. By cross-correlating deep Chandra X-ray and SCUBA sub-mm data for 34 sources, it finds no significant overlap: X-ray bright sources are sub-mm faint, and sub-mm bright sources are X-ray faint. The key result is that 2–10 keV sources brighter than 10⁻¹⁵ erg s⁻¹ cm⁻²—responsible for >75% of the X-ray background—contribute less than 7% to the sub-mm background, indicating the two backgrounds are likely unrelated phenomena.
Obscured AGNs are thought to contribute a large fraction of the hard X-ray background (2-10 keV), and have also been proposed as the powerhouse of a fraction of the SCUBA sources which make most of the background at 850um, thus providing a link between the two spectral windows. We have tackled this issue by comparing data at 2-10 keV and at 850um for a sample of 34 sources at fluxes (or limiting fluxes) which resolve most of the background in the two bands. We present here new SCUBA observations, and new correlations between separate data sets retrieved from the literature. Similar correlations presented by others are added for completeness. None of the 11 hard X-ray (2-10 keV) sources has a counterpart at 850um, with the exception of a Chandra source in the SSA13 field, which is a candidate type 2, heavily absorbed QSO at high redshift. The ratios F(850um)/F(5keV) (mostly upper limits) of the X-ray sources are significantly lower than the value observed for the cosmic background. In particular, we obtain that 2-10 keV sources brighter than 10^-15 erg s^-1 cm^-2, which make at least 75% of the background in this band, contribute for less than 7% to the submillimeter background. Out of the 24 SCUBA sources, 23 are undetected by Chandra. The ratios F(850um)/F(5keV) (mostly lower limits) of these SCUBA sources indicate that most of them must be powered either by starburst activity, or by an AGN which is obscured by a column Nh > 10^25 cm^-2, with a reflection efficiency in the hard X rays significantly lower than 1% in most cases. However, AGNs of this type could not contribute significantly to the 2-10 keV background.
Motivation & Objective
- To determine if the hard X-ray (2–10 keV) and submillimeter (850 µm) backgrounds originate from the same population of obscured AGNs.
- To test the hypothesis that heavily absorbed AGNs power both the X-ray and sub-mm backgrounds via reprocessing of X-ray emission into sub-mm wavelengths.
- To quantify the contribution of 2–10 keV X-ray sources to the 850 µm sub-mm background using deep multi-wavelength data.
- To assess whether the sub-mm bright sources detected by SCUBA are powered by AGNs or starbursts, based on their X-ray non-detections.
Proposed method
- Conducted new SCUBA observations at the JCMT for a subsample of BeppoSAX HELLAS sources.
- Combined new data with existing deep Chandra X-ray and SCUBA observations from SSA13, HDF-N, and lensing cluster fields.
- Performed cross-correlation between 2–10 keV X-ray and 850 µm sub-mm data for 34 sources at flux levels resolving >70% of both backgrounds.
- Used flux ratios F₈₅₀µm / F₅keV as diagnostic: upper limits for X-ray sources and lower limits for sub-mm sources to constrain emission mechanisms.
- Compared observed flux ratios with theoretical templates (e.g., Arp 220 starburst, NGC 1068 reflection-dominated AGN) to infer dominant energy sources.
- Applied conservative assumptions to estimate maximum possible contribution of X-ray sources to the sub-mm background, using flux limits and background normalization.
Experimental results
Research questions
- RQ1Do the hard X-ray (2–10 keV) and submillimeter (850 µm) backgrounds arise from the same population of obscured AGNs?
- RQ2What fraction of the 2–10 keV X-ray background is contributed by sources detectable at 850 µm?
- RQ3Are the submillimeter-bright sources in the SCUBA survey powered by AGNs or starbursts, based on their X-ray non-detections?
- RQ4Can Compton-thick AGNs with low X-ray reflection efficiency explain the sub-mm emission without contributing significantly to the X-ray background?
- RQ5Is there a significant correlation between X-ray and sub-mm emission in individual sources at flux levels resolving most of the cosmic background?
Key findings
- None of the 11 hard X-ray (2–10 keV) sources brighter than 10⁻¹⁵ erg s⁻¹ cm⁻² have a detectable 850 µm counterpart, except one Chandra source in SSA13, which is a high-redshift type 2, heavily absorbed QSO.
- The 2–10 keV sources brighter than 10⁻¹⁵ erg s⁻¹ cm⁻²—responsible for at least 75% of the X-ray background—contribute less than 7% to the sub-mm background under conservative assumptions.
- Out of 24 SCUBA sources, 23 are undetected in the 2–10 keV band down to a flux limit of ~1–2×10⁻¹⁵ erg s⁻¹ cm⁻², indicating weak or absent hard X-ray emission.
- The F₈₅₀µm / F₅keV ratios of SCUBA sources (mostly lower limits) suggest they are powered by starbursts or AGNs obscured by N_H > 10²⁵ cm⁻² with reflection efficiency <1%.
- The class of AGNs inferred to power the sub-mm sources (Compton-thick, low-reflection) is not expected to contribute significantly to the X-ray background, confirming the two backgrounds are likely unrelated.
- The X-ray data, primarily from Chandra, may be biased toward softer X-ray emission due to declining effective area at high energies, suggesting future XMM observations could reveal fainter, harder sources.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.