[Paper Review] Subnanotesla quantum-interference magnetometry with a single spin in diamond
This paper demonstrates subnanotesla quantum-interference magnetometry using a single nitrogen-vacancy (NV) center in isotopically purified diamond by coherently driving transitions between the |+1⟩ and |-1⟩ states via two-photon Rabi pulses. The method achieves a magnetic field sensitivity of 2.2 nT/Hz¹/² for oscillating fields and 800 pT Allan deviation for static fields, significantly improving coherence and stability over conventional |0⟩–|−1⟩ qubit operation.
We demonstrate a magnetometry technique using nitrogen-vacancy centres in diamond which makes use of coherent two-photon transitions. We find that the sensitivity to magnetic fields can be significantly improved in isotopically purified diamond. Furthermore, the long-term stability of magnetic field measurements is significantly enhanced, thereby reducing the minimum detectable long-term field variations for both quasi-static and periodic fields. The method is useful both for sensing applications and as a spin qubit manipulation technique.
Motivation & Objective
- To improve magnetic field sensitivity and long-term stability in NV-center-based quantum magnetometry.
- To reduce dephasing in NV centers by utilizing the |±1⟩ spin sublevel manifold instead of the conventional |0⟩–|−1⟩ basis.
- To demonstrate that coherent two-photon driving in a spin-1 system enables enhanced coherence and reduced sensitivity to strain and transverse field fluctuations.
- To enable high-sensitivity detection of both static and periodic magnetic fields using engineered quantum interference in a single NV center.
Proposed method
- The NV center is initialized in the |0⟩ state and coherently driven into a superposition of |+1⟩ and |-1⟩ states using STIRAP-like two-photon microwave pulses with detuned Rabi frequencies Ω₊ and Ω₋.
- A 30 mT axial magnetic bias field is applied to minimize coupling to transverse field fluctuations and strain, stabilizing the |±1⟩ qubit states.
- The system's Hamiltonian is engineered in a rotating frame to create an effective two-level system between |+1⟩ and |-1⟩, with coherent coupling mediated by detuned microwave fields.
- Coherence times T₂(±1) are measured using a rephasing sequence involving symmetric, Gaussian-shaped pulses on both Ω₊ and Ω₋, enabling long phase accumulation.
- Magnetic field sensitivity is quantified via the minimum detectable field amplitude, derived from photon shot noise and coherence decay, with p ≈ 2.0 for both systems.
- Allan deviation is used to assess long-term stability, comparing DC and AC measurements in the |0⟩–|−1⟩ and |±1⟩ bases under identical environmental conditions.
Experimental results
Research questions
- RQ1Can coherent two-photon driving between |+1⟩ and |-1⟩ states in a diamond NV center significantly improve spin coherence time compared to the standard |0⟩–|−1⟩ basis?
- RQ2Does the |±1⟩ qubit state configuration reduce sensitivity to strain and transverse magnetic field fluctuations, leading to enhanced field sensing performance?
- RQ3To what extent does the use of the |±1⟩ manifold improve the minimum detectable field for both static and periodic magnetic fields?
- RQ4How does the long-term stability of magnetic field measurements scale with integration time when using the |±1⟩ qubit state versus the |0⟩–|−1⟩ state?
- RQ5Can the common-mode rejection of noise in the |±1⟩ basis enable shot-noise-limited AC magnetometry over extended durations?
Key findings
- The coherence time T₂(±1) in the |±1⟩ qubit basis reaches (2.36 ± 0.09) ms, a significant improvement over T₂(0,−1) = (1.66 ± 0.16) ms in the conventional |0⟩–|−1⟩ basis.
- The minimum detectable field for oscillating fields is reduced to 2.2 nT/Hz¹/² using the |±1⟩ basis, compared to 6 nT/Hz¹/² in the |0⟩–|−1⟩ basis.
- The Allan deviation for static field measurements reaches 800 pT in the |±1⟩ basis over integration times of ~30 minutes, compared to 10 nT after ~1 minute in the |0⟩–|−1⟩ basis.
- The coherence decay exponent p is measured as 2.02 ± 0.10 for the |±1⟩ system and 2.03 ± 0.38 for the |0⟩–|−1⟩ system, indicating similar decay shapes but superior performance in the |±1⟩ case due to longer T₂.
- AC magnetometry using the |±1⟩ basis achieves shot-noise-limited behavior with an Allan deviation of ~50 pT over 30-minute intervals, limited only by photon statistics and measurement duration.
- The improved stability and sensitivity stem from reduced sensitivity to strain and transverse field fluctuations, as well as common-mode noise rejection in the |±1⟩ qubit manifold.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.