[Paper Review] Superconducting cavity qubit with tens of milliseconds single-photon coherence time
This paper demonstrates a superconducting cavity qubit with a single-photon coherence time of 34 ms—over tenfold longer than previous results—by using a high-purity niobium cavity with minimal surface losses and weak coupling to a transmon for qubit control. The system enables the preparation of a 1024-photon Schrödinger cat state, showcasing potential for bosonic quantum error correction.
Storing quantum information for an extended period of time is essential for running quantum algorithms with low errors. Currently, superconducting quantum memories have coherence times of a few milliseconds, and surpassing this performance has remained an outstanding challenge. In this work, we report a qubit encoded in a novel superconducting cavity with a coherence time of 34 ms, an improvement of over an order of magnitude compared to previous demonstrations. We use this long-lived quantum memory to store a Schrödinger cat state with a record size of 1024 photons, indicating the cavity's potential for bosonic quantum error correction.
Motivation & Objective
- Extend quantum coherence times in superconducting circuits to support fault-tolerant quantum computation and quantum networks.
- Overcome the limitation of short coherence times in superconducting cavity qubits caused by surface oxide losses and transmon-induced decoherence.
- Develop a high-coherence quantum memory capable of storing large Fock-state superpositions for bosonic quantum error correction.
- Demonstrate a scalable platform for long-lived quantum information storage using microwave cavities with engineered surface properties.
Proposed method
- Fabricated a high-purity niobium cavity using electron-beam welding and surface polishing to minimize lossy surface oxides.
- Employed a half-elliptical cavity geometry to concentrate electric fields at the transmon coupling point, reducing chip-induced losses.
- Coupled the cavity weakly to a transmon qubit via a stripline resonator to minimize decoherence while enabling quantum state manipulation.
- Used strong parametric drives to compensate for low coupling rates and reduce transmon-induced errors.
- Performed classical ring-down measurements at 10 mK to characterize the bare cavity, achieving a decay time of 0.11 s (Q₀ ≈ 3×10⁹).
- Applied quantum tomography and parity measurements to verify cat state preparation and fidelity, using a TWPA and HEMT amplifiers for low-noise readout.
Experimental results
Research questions
- RQ1Can a superconducting cavity qubit achieve single-photon coherence times exceeding 10 ms through improved surface engineering and coupling control?
- RQ2To what extent does weak transmon coupling mitigate decoherence and nonlinear effects in high-Q cavities?
- RQ3Can a Schrödinger cat state with over 1000 photons be prepared and coherently maintained in a microwave cavity?
- RQ4How do photon loss, transmon readout infidelity, and Kerr nonlinearity collectively limit the visibility of large cat state interference fringes?
- RQ5What is the role of cavity surface quality and environmental coupling in determining the ultimate coherence time of a single-photon qubit?
Key findings
- The cavity achieved a single-photon relaxation time of T₁ᶜ = 25.6 ± 0.2 ms and a coherence time of T₂ᶜ = 34 ± 1 ms, representing an order-of-magnitude improvement over prior work.
- Classical ring-down measurements of the bare cavity yielded a decay time of 0.11 s (Q₀ = 3×10⁹), approaching values from vacuum-annealed niobium cavities without thermal treatment.
- A Schrödinger cat state with a size of 1024 photons was prepared and characterized, marking a tenfold increase in photon number over previous demonstrations.
- Fringe visibility in parity measurements decreased from 0.95 for small cat states to 0.86 for the 1024-photon state, indicating reduced measurement fidelity at high photon numbers.
- Simulations showed that observed visibility for large cat states was significantly lower than predicted, suggesting unaccounted errors such as calibration sensitivity or nonlinear effects beyond the dispersive model.
- The cavity Kerr nonlinearity was measured at Kc = 2π × 3.6 Hz, with a phase collapse time of 4 ms—longer than the 54 μs coherence time of the cat state—indicating that Kerr effects do not dominate the decoherence.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.