Skip to main content
QUICK REVIEW

[Paper Review] Symmetry properties and widths of the filamentary structures in the Orion A giant molecular cloud

Yuqing Zheng, Hong-Chi Wang|arXiv (Cornell University)|Mar 19, 2021
Astrophysics and Star Formation StudiesPhysics and Astronomy89 references4 citations
TL;DR

This study analyzes 46 long filaments in the Orion A giant molecular cloud using H2 column density maps from MWISP CO line observations, deriving radial column density profiles for 397 segments. It finds that 65.3% of segments are intrinsically asymmetric, with symmetrical segments showing a median full width at half maximum (FWHM) of ~0.67 pc (Plummer-like fit) and ~0.50 pc (Gaussian fit), indicating that filament width is not universally constant and symmetry strongly influences width estimates.

ABSTRACT

We identify 225 filaments from an H$_2$ column density map constructed using simultaneous $^{12}$CO, $^{13}$CO, and C$^{18}$O (J=1-0) observations carried out as a part of the MWISP project. We select 46 long filaments with lengths above 1.2 pc to analyze the filament column density profiles. We divide the selected filaments into 397 segments and calculate the column density profiles for each segment. The symmetries of the profiles are investigated. The proportion of intrinsically asymmetrical segments is 65.3$\%$, and that of intrinsically symmetrical ones is 21.4$\%$. The typical full width at half maximum (FWHM) of the intrinsically symmetrical filament segments is $\sim$ 0.67 pc with the Plummer-like fitting, and $\sim$ 0.50 pc with the Gaussian fitting, respectively. The median FWHM widths derived from the second-moment method for intrinsically symmetrical and asymmetrical profiles are $\sim$ 0.44 and 0.46 pc, respectively. Close association exists between the filamentary structures and the YSOs in the region.

Motivation & Objective

  • To investigate the symmetry properties of filamentary structures in the Orion A giant molecular cloud.
  • To measure the widths of filament segments using multiple fitting methods (Plummer-like, Gaussian, second-moment) to assess consistency and variability.
  • To examine the relationship between filament width, symmetry, and local star formation activity.
  • To evaluate the impact of fitting range selection and observational beam effects on derived width measurements.
  • To determine whether filament width is a universal property or varies with morphology and dynamical state.

Proposed method

  • Constructed an H2 column density map using simultaneous 12CO, 13CO, and C18O (J=1-0) line observations from the MWISP survey.
  • Identified 225 filaments and selected 46 long filaments (>1.2 pc) for detailed analysis of radial column density profiles.
  • Divided selected filaments into 397 segments and computed column density profiles for each using position-velocity slices.
  • Classified each profile’s intrinsic symmetry (symmetrical, asymmetrical, or unknown) based on shape analysis.
  • Fitted each profile with Plummer-like and Gaussian functions, and computed widths via the second-moment method.
  • Used error propagation (equation 8) to estimate uncertainties in profile measurements and fitting parameters.

Experimental results

Research questions

  • RQ1What fraction of filament segments in Orion A exhibit intrinsic symmetry versus asymmetry in their column density profiles?
  • RQ2How do the full width at half maximum (FWHM) widths of symmetric and asymmetric filaments compare across different fitting methods?
  • RQ3Does the choice of fitting range significantly affect the derived filament width, particularly for symmetric profiles?
  • RQ4Is there a correlation between filament width and central column density or spatial location (e.g., northern vs. southern Orion A)?
  • RQ5How are filamentary structures spatially correlated with young stellar objects (YSOs) in the region?

Key findings

  • 65.3% of filament segments are intrinsically asymmetrical, while 21.4% are intrinsically symmetrical, indicating asymmetry is the dominant morphology.
  • The median FWHM width of intrinsically symmetrical segments is ~0.67 pc when fitted with a Plummer-like function and ~0.50 pc with a Gaussian function.
  • The second-moment method yields median widths of ~0.44 pc for symmetrical profiles and ~0.46 pc for asymmetrical profiles, showing minimal difference.
  • The FWHM width derived from Plummer-like fitting is systematically larger than that from Gaussian fitting, with a median difference of ~0.17 pc.
  • There is no significant correlation between filament width and central column density, suggesting width is not solely determined by density.
  • A strong spatial association exists between filamentary structures and young stellar objects (YSOs), particularly in the active northern region of Orion A.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.