Skip to main content
QUICK REVIEW

[Paper Review] Targetless Calibration of LiDAR-IMU System Based on Continuous-time Batch Estimation

Jiajun Lv, Jinhong Xu|arXiv (Cornell University)|Jul 29, 2020
Robotics and Sensor-Based LocalizationEngineering30 references5 citations
TL;DR

This paper proposes LI-Calib, a targetless LiDAR-IMU calibration method using continuous-time batch estimation with B-Spline parameterized trajectories and surfel-based data association. It achieves high accuracy and repeatability in structured environments by jointly minimizing IMU raw measurements and LiDAR point-to-surfel residuals, with sub-millimeter translation and sub-degree rotation errors in real-world experiments and open-source code availability.

ABSTRACT

Sensor calibration is the fundamental block for a multi-sensor fusion system. This paper presents an accurate and repeatable LiDAR-IMU calibration method (termed LI-Calib), to calibrate the 6-DOF extrinsic transformation between the 3D LiDAR and the Inertial Measurement Unit (IMU). % Regarding the high data capture rate for LiDAR and IMU sensors, LI-Calib adopts a continuous-time trajectory formulation based on B-Spline, which is more suitable for fusing high-rate or asynchronous measurements than discrete-time based approaches. % Additionally, LI-Calib decomposes the space into cells and identifies the planar segments for data association, which renders the calibration problem well-constrained in usual scenarios without any artificial targets. We validate the proposed calibration approach on both simulated and real-world experiments. The results demonstrate the high accuracy and good repeatability of the proposed method in common human-made scenarios. To benefit the research community, we open-source our code at \url{https://github.com/APRIL-ZJU/lidar_IMU_calib}

Motivation & Objective

  • To develop a high-accuracy, repeatable LiDAR-IMU calibration method without requiring artificial targets or additional sensors.
  • To address the challenge of calibrating high-rate or asynchronous LiDAR and IMU measurements in dynamic environments.
  • To improve data association reliability in calibration by using a surfel-based representation and adaptive plane-likeness thresholds.
  • To ensure the calibration problem is well-constrained in typical human-made environments through geometric constraints from planar structures.
  • To provide a fully open-source calibration toolbox to benefit the robotics and perception research community.

Proposed method

  • The method uses B-Spline parameterization to model the continuous-time trajectory of the LiDAR-IMU system, enabling exact pose estimation at any time instant.
  • It jointly minimizes residuals from raw IMU measurements (acceleration and angular velocity) and point-to-surfel distances in a continuous-time batch optimization framework.
  • The point cloud is discretized into surfels (tiny planes), and data association is performed between LiDAR points and their corresponding surfels to improve robustness.
  • A two-stage thresholding strategy is applied: initial plane-likeness threshold of 0.6, increased to 0.7 after motion compensation to refine the surfel map.
  • The method relies on NDT-based LiDAR odometry in the first iteration to generate an initial surfel map and motion-compensated point cloud.
  • Knot spacing of 0.02 seconds is used to handle highly dynamic motion, ensuring sufficient temporal resolution for accurate trajectory representation.

Experimental results

Research questions

  • RQ1Can a targetless LiDAR-IMU calibration method achieve high accuracy and repeatability in real-world, structured environments without artificial markers or additional sensors?
  • RQ2How does continuous-time trajectory modeling with B-Splines improve calibration accuracy compared to discrete-time interpolation methods, especially under high-rate or asynchronous sensor data?
  • RQ3To what extent does surfel-based data association enhance calibration robustness and convergence compared to traditional point-to-plane or point-to-model methods?
  • RQ4How does the iterative refinement of the surfel map and plane-likeness threshold affect calibration accuracy and convergence?
  • RQ5What is the impact of initial LiDAR odometry quality on the final calibration performance, and how can it be mitigated?

Key findings

  • The proposed method achieves an average absolute trajectory error (ATE) of 0.0183 m when compared to a motion-capture system across ten real-world sequences.
  • In indoor environments, the final calibration differences are within 0.0017 m (1.7 mm) for translation and 0.67° for yaw rotation, demonstrating high repeatability.
  • For relative poses between IMUs, the translation differences from CAD reference are less than 2 mm, and rotation differences are below 1°, confirming high accuracy.
  • The method shows significant improvement between the first and second iterations, attributed to improved surfel map and data correspondence quality after motion compensation.
  • After approximately four iterations, calibration results converge and remain stable, indicating robust convergence behavior.
  • The method is highly repeatable across different sequences, especially for rotation estimation, and performs well in structured, human-made environments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.