[Paper Review] Technical Note: Towards Virtual Monitors for Image Guided Interventions - Real-time Streaming to Optical See-Through Head-Mounted Displays
This paper presents a real-time virtual monitor system that streams high-resolution medical images to optical see-through head-mounted displays (OST-HMDs) for image-guided interventions, enabling head-, world-, or body-anchored mixed reality visualization. The system achieves an average end-to-end delay of 214±30 ms and a refresh rate of 41.4±32.0 Hz, demonstrating feasibility for pre-clinical evaluation in X-ray-guided procedures.
Purpose: Image guidance is crucial for the success of many interventions. Images are displayed on designated monitors that cannot be positioned optimally due to sterility and spatial constraints. This indirect visualization causes potential occlusion, hinders hand-eye coordination, leads to increased procedure duration and surgeon load. Methods: We propose a virtual monitor system that displays medical images in a mixed reality visualization using optical see-through head-mounted displays. The system streams high-resolution medical images from any modality to the head-mounted display in real-time that are blended with the surgical site. It allows for mixed reality visualization of images in head-, world-, or body-anchored mode and can thus be adapted to specific procedural needs. Results: For typical image sizes, the proposed system exhibits an average end-to-end delay and refresh rate of 214 +- 30 ms and 41:4 +- 32:0 Hz, respectively. Conclusions: The proposed virtual monitor system is capable of real-time mixed reality visualization of medical images. In future, we seek to conduct first pre-clinical studies to quantitatively assess the impact of the system on standard image guided procedures.
Motivation & Objective
- To address the limitations of conventional monitors in image-guided interventions, which are often poorly positioned due to sterility and spatial constraints.
- To reduce surgeon workload and improve hand-eye coordination by enabling in-line visualization of medical images through mixed reality.
- To develop a system that streams high-resolution images from any medical imaging modality to an optical see-through HMD in real time.
- To evaluate the performance of the system in terms of end-to-end delay, frame rate stability, and rendering refresh rate across varying image sizes.
- To enable future pre-clinical studies assessing the system's impact on surgical workflow and procedural efficiency.
Proposed method
- The system uses a frame grabber to capture video output from medical imaging modalities such as fluoroscopy, C-arm CBCT, ultrasound, CT, and MRI.
- A dedicated image processing unit performs real-time scaling and compression of the incoming image stream to optimize for HMD rendering.
- Medical images are transmitted over a network to a Microsoft HoloLens OST-HMD, which overlays the images onto the real surgical field using spatial tracking.
- The system supports three display modes: head-anchored (fixed relative to the user's head), world-anchored (fixed in the room), and body-anchored (fixed to the patient's anatomy).
- Image rendering is synchronized with the HMD’s refresh cycle, and texture loading is optimized for real-time performance.
- Performance is evaluated by measuring end-to-end delay, frame reception rate, and rendering refresh rate across multiple image sizes (620×480 to 1920×1080 pixels in RGB24).
Experimental results
Research questions
- RQ1Can real-time streaming of high-resolution medical images to an optical see-through HMD achieve acceptable latency and frame rate for clinical use in image-guided interventions?
- RQ2How does the system perform across different image sizes and modalities in terms of end-to-end delay and refresh rate?
- RQ3What are the primary performance bottlenecks in the image streaming pipeline, and can they be isolated and quantified?
- RQ4Does the system enable stable, in-line visualization of medical images that improves hand-eye coordination compared to conventional monitors?
- RQ5Is the system suitable for deployment in pre-clinical studies of X-ray-guided procedures?
Key findings
- The system achieves an average end-to-end delay of 214±30 ms, with the frame grabber and image processing unit being the primary contributors to latency, each contributing approximately 100 ms on average.
- The average refresh rate across typical image sizes is 41.4±32.0 Hz, with effective frame rates exceeding 30 Hz for images smaller than 1000×1000 pixels in RGB24.
- For 1920×1080 image resolution, the system maintains a refresh rate of 16.4±6.5 Hz with a texture loading delay of 61.3±81.7 ms, indicating rendering as a key performance bottleneck.
- The frame reception rate varies significantly across image sizes, with a standard deviation of up to 44.6 Hz for 620×480 images, suggesting inconsistent data arrival and potential frame bunching.
- The system demonstrates stable mixed reality visualization in all three modes (head-, world-, and body-anchored), enabling flexible adaptation to procedural needs.
- The results indicate that the system is suitable for pre-clinical evaluation in X-ray-guided interventions, which typically operate at 7.5–30 Hz, despite current limitations in frame rate consistency.
Read this paper