TL;DR

This paper proposes a subjective visual quality assessment study for frame interpolation results using crowdsourcing to evaluate 141 optical flow algorithms from the Middlebury benchmark. By applying Thurstone's model to paired comparison data, the study re-ranks algorithms based on human-perceived quality, revealing significant discrepancies with RMSE-based rankings and highlighting the inadequacy of standard objective metrics like RMSE and FR-IQA methods for assessing interpolated frame quality.

ABSTRACT

Current benchmarks for optical flow algorithms evaluate the estimation quality by comparing their predicted flow field with the ground truth, and additionally may compare interpolated frames, based on these predictions, with the correct frames from the actual image sequences. For the latter comparisons, objective measures such as mean square errors are applied. However, for applications like image interpolation, the expected user's quality of experience cannot be fully deduced from such simple quality measures. Therefore, we conducted a subjective quality assessment study by crowdsourcing for the interpolated images provided in one of the optical flow benchmarks, the Middlebury benchmark. We used paired comparisons with forced choice and reconstructed absolute quality scale values according to Thurstone's model using the classical least squares method. The results give rise to a re-ranking of 141 participating algorithms w.r.t. visual quality of interpolated frames mostly based on optical flow estimation. Our re-ranking result shows the necessity of visual quality assessment as another evaluation metric for optical flow and frame interpolation benchmarks.

Motivation & Objective

  • To address the limitation of objective metrics like RMSE and FR-IQA in reflecting human-perceived visual quality of interpolated frames.
  • To conduct a large-scale, reliable subjective quality assessment of interpolated frames using crowdsourcing to establish ground-truth human perception scores.
  • To re-rank 141 optical flow algorithms based on human visual quality perception rather than RMSE or FR-IQA scores.
  • To demonstrate that current objective quality metrics do not correlate well with human perception for interpolated frames with motion-compensated artifacts.
  • To provide a new benchmark for visual quality assessment that complements existing objective metrics in optical flow and frame interpolation evaluation.

Proposed method

  • Conducted a crowdsourced paired comparison study using forced-choice judgments to assess visual quality of interpolated frames from 141 optical flow algorithms.
  • Applied Thurstone's model with classical least squares to reconstruct absolute quality scores from paired comparison data.
  • Used the Middlebury benchmark's interpolated frames and ground-truth sequences as input for subjective evaluation.
  • Compared the resulting subjective rankings with the original RMSE-based rankings from the Middlebury benchmark.
  • Evaluated the correlation between established FR-IQA methods (SSIM, MS-SSIM, FSIM, VSI) and the subjective quality scores.
  • Collected and processed data from 141 algorithms across 9 test sequences to generate a comprehensive re-ranking.

Experimental results

Research questions

  • RQ1How do human observers rate the visual quality of interpolated frames produced by 141 optical flow algorithms?
  • RQ2To what extent do standard objective metrics like RMSE and FR-IQA methods correlate with human perception of interpolated frame quality?
  • RQ3How does the re-ranking of algorithms based on subjective visual quality compare to the RMSE-based ranking in the Middlebury benchmark?
  • RQ4What specific distortions in interpolated frames lead to perceptual differences not captured by RMSE or FR-IQA?
  • RQ5Can a crowdsourced subjective quality assessment provide a more reliable evaluation metric for frame interpolation than current objective benchmarks?

Key findings

  • The subjective quality assessment revealed significant discrepancies between the RMSE-based ranking and human perception, with some algorithms ranked highly by RMSE but poorly by human observers.
  • The correlation between FR-IQA methods (e.g., VSI) and human perception was low, with SROCC values ranging from 0.494 to 0.854 across sequences, indicating poor predictive power for interpolated frames.
  • Even when RMSE values were identical, interpolated frames showed clear visual quality differences, demonstrating that RMSE alone is insufficient for quality evaluation.
  • The re-ranking based on subjective data showed that algorithms producing smoother, more natural motion artifacts were preferred, even if they had higher RMSE.
  • The study provides a new, reliable ground-truth dataset of subjective quality scores for 141 interpolated frames, enabling future development of perception-aware FR-IQA methods.
  • The results emphasize the necessity of incorporating visual quality assessment as a complementary metric in optical flow and frame interpolation benchmarks.