Skip to main content
QUICK REVIEW

[Paper Review] Terzina on board NUSES: a pathfinder for EAS Cherenkov Light Detection from space

L. Burmistrov|arXiv (Cornell University)|Apr 24, 2023
Astrophysics and Cosmic PhenomenaPhysics and Astronomy5 citations
TL;DR

Terzina is a space-based Cherenkov telescope on the NUSES mission designed to detect ultra-high-energy cosmic rays (UHECRs) above 100 PeV by observing Cherenkov light from extensive air showers (EAS) at the Earth's limb. Using a dual-mirror optical system and a SiPM-based focal plane camera, it demonstrates the feasibility of space-based EAS detection, with simulation-based trigger optimization enabling 120 Hz single-pixel and 1250 Hz two-pixel coincidence rates under data rate constraints.

ABSTRACT

In this paper we introduce the Terzina telescope as a part of the NUSES space mission. This telescope aims to detect Ultra High Energy Cosmic Rays (UHECRs) through the Cherenkov light emission from the extensive air showers (EAS) that they create in the Earth's atmosphere. The Cherenkov photons are aligned along the shower axis inside about $\sim 0.2-1^{\circ}$, so that they become detectable by Terzina when it points towards the Earth's limb. A sun-synchronous orbit will allow the telescope to observe only the night side of the Earth's atmosphere. In this contribution, we focus on the description of the telescope detection goals, geometry, optical design and its photon detection camera composed of Silicon Photo-Multipliers (SiPMs). Moreover, we describe the full Monte Carlo simulation chain developed to estimate Terzina's performance for UHECR detection. The estimate of the radiation damage and light background rates, the readout electronics and trigger logic are briefly described. Terzina will be able to study the potential for future physics missions devoted to UHECR detection and to UHE neutrino astronomy. It is a pathfinder for missions like POEMMA or future constellations of similar satellites to NUSES.

Motivation & Objective

  • To demonstrate the feasibility of detecting Cherenkov light from extensive air showers (EAS) induced by ultra-high-energy cosmic rays (UHECRs) from low Earth orbit.
  • To validate the design and performance of a space-based telescope using silicon photomultipliers (SiPMs) for photon detection in the near-UV range.
  • To establish a full Monte Carlo simulation chain for estimating detection efficiency, background rates, and trigger performance under radiation and thermal constraints.
  • To optimize trigger logic and readout electronics to meet a 45 Gbit/day data throughput limit while maintaining sensitivity to UHECR signals.
  • To serve as a pathfinder for future space-based missions such as POEMMA, enabling UHE neutrino and UHECR astronomy from orbit.

Proposed method

  • The telescope employs a dual-parabolic mirror system with a corrector lens to achieve a 925 mm effective focal length within a 394 mm diameter envelope, optimized for high angular resolution and minimal aberration.
  • The focal plane assembly (FPA) uses 10 SiPM arrays (8×8 pixels each) with a 3×3 mm² pixel size, providing a 7.2° horizontal and 2.5° vertical field of view, aligned to observe the Earth's limb at 67.5° from nadir.
  • Frontend electronics use 10 custom ASICs, each reading 64 SiPM channels with a 35 MHz bandwidth amplifier and threshold-based digitization, enabling low-noise, high-speed signal processing.
  • A parametric waveform simulation chain models photon signals, dark count rate (DCR), and noise background (NGB), with DCR estimated at 77 kHz/mm² and cross-talk at 6.6% for NUV-HD-MT SiPMs.
  • Trigger logic is implemented in two modes: single-pixel (threshold in p.e.) and two-pixel coincidence (cluster trigger), with thresholds dynamically adjusted over mission life to maintain data rate below 45 Gbit/day.
  • The coincidence rate is computed using the formula $ 2 imes R_1^2 imes au imes 2100 $, where $ R_1 $ is the single-pixel rate, $ au $ is the coincidence window, and 2100 is the number of two-pixel clusters per full camera.

Experimental results

Research questions

  • RQ1Can Cherenkov light from extensive air showers (EAS) induced by UHECRs be effectively detected from a satellite platform in low Earth orbit?
  • RQ2What is the optimal trigger threshold and configuration (single vs. two-pixel coincidence) to maintain data throughput below 45 Gbit/day while maximizing UHECR detection efficiency?
  • RQ3How do radiation-induced damage and background noise (NGB + DCR) affect SiPM performance over the mission lifetime, and how can they be mitigated through dynamic thresholding?
  • RQ4To what extent can the optical design and SiPM camera configuration resolve the direction and intensity of Cherenkov light from EAS at the Earth's limb?
  • RQ5How does the simulation chain accurately predict signal-to-noise ratios and trigger rates under varying orbital and environmental conditions?

Key findings

  • The single-pixel trigger threshold must be increased from 9.2 p.e. at beginning-of-life (BoL) to 14.3 p.e. at end-of-life (EoL) to maintain a maximum rate of 120 Hz, accounting for radiation-induced gain degradation.
  • The two-pixel coincidence trigger threshold is set at 5.2 p.e. (BoL) to 8.8 p.e. (EoL), enabling a maximum coincidence rate of 1250 Hz while staying within the 45 Gbit/day data limit.
  • The system achieves a dead time of less than 1% when processing 240 Hz trigger events from single and two-pixel configurations, with a total readout time of ~7.4 ms per second.
  • The simulation chain successfully models photon surface density and signal waveforms, showing that the highest detectable signal occurs at ~30 km atmospheric depth for 100 PeV protons.
  • The FPA’s 10 SiPM arrays (8×8 pixels each) provide a total of 640 channels, with a 3×3 mm² pixel size compatible with the telescope’s 0.18° angular resolution and 7.2° field of view.
  • Radiation damage is estimated to be primarily from electrons, secondary gammas, and protons, with power consumption and noise performance maintained through optimized bias and amplifier design.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.