Skip to main content
QUICK REVIEW

[Paper Review] Testing of Quantum Gravity With Sub-Kilogram Acoustic Resonators

Pavel Bushev, Jeremy Bourhill|arXiv (Cornell University)|Mar 8, 2019
Noncommutative and Quantum Gravity TheoriesPhysics and Astronomy1 citations
TL;DR

This paper tests quantum gravity effects using sub-kilogram acoustic resonators by detecting amplitude-dependent frequency shifts arising from modified [x,p] commutation relations. Using a 0.3 kg sapphire resonator and a 10 mg quartz resonator, it sets upper limits on the quantum gravity correction constant β₀ < 5×10⁶ and β₀ < 4×10⁴, respectively, improving prior bounds and demonstrating the superiority of electro-mechanical systems for probing generalized uncertainty principles.

ABSTRACT

Recent progress in observing and manipulating mechanical oscillators at quantum regime provides new opportunities of studying fundamental physics, for example, to search for low energy signatures of quantum gravity. For example, it was recently proposed that such devices can be used to test quantum gravity effects, by detecting the change in the [x,p] commutation relation that could result from quantum gravity corrections. We show that such a correction results in a dependence of a resonant frequency of a mechanical oscillator on its amplitude, which is known as amplitude-frequency effect. By implementing this new method we measure amplitude-frequency effect for 0.3 kg ultra high-Q sapphire split-bar mechanical resonator and for 10 mg quartz bulk acoustic wave resonator. Our experiments with sapphire resonator have established the upper limit on quantum gravity correction constant for $\beta_0<5 imes10^6$ which is a factor of 6 better than previously detected. The reasonable estimates of $\beta_0$ from experiments with quartz resonators yield an even more stringent limit of $4 imes10^4$. The data sets of 1936 measurement of physical pendulum period by Atkinson results in significantly stronger limitations on $\beta_0 \ll 1$. Yet, due to the lack of proper pendulum frequency stability measurement in these experiments, the exact upper bound on $\beta_0$ can not be reliably established. Moreover, pendulum based systems only allow testing a specific form of the modified commutator that depends on the mean value of momentum. The electro-mechanical oscillators to the contrary enable testing of any form of generalized uncertainty principle directly due to much higher stability and a higher degree of control.

Motivation & Objective

  • To probe low-energy signatures of quantum gravity using mechanical oscillators operating in the quantum regime.
  • To test modifications to the [x,p] commutation relation predicted by quantum gravity models.
  • To improve existing bounds on the quantum gravity correction constant β₀ using high-stability mechanical resonators.
  • To compare the effectiveness of electro-mechanical oscillators versus pendulum-based systems for testing generalized uncertainty principles.

Proposed method

  • Measuring the amplitude-frequency effect in ultra-high-Q mechanical resonators as a signature of modified [x,p] commutation relations.
  • Using a 0.3 kg sapphire split-bar resonator and a 10 mg quartz bulk acoustic wave resonator to detect deviations in resonant frequency due to quantum gravity corrections.
  • Applying high-stability frequency measurement techniques to extract β₀ from observed amplitude-dependent frequency shifts.
  • Analyzing historical data from 1936 physical pendulum experiments by Atkinson to assess constraints on β₀, despite stability limitations.
  • Comparing the sensitivity of electro-mechanical systems to pendulum systems for testing different forms of the generalized uncertainty principle.
  • Using the modified commutator formalism to link amplitude-frequency shifts to the quantum gravity parameter β₀.

Experimental results

Research questions

  • RQ1Can amplitude-frequency shifts in mechanical resonators be used to detect quantum gravity effects via modified [x,p] commutation relations?
  • RQ2What are the improved upper bounds on the quantum gravity correction constant β₀ using high-Q acoustic resonators?
  • RQ3How do electro-mechanical resonators compare to pendulum-based systems in testing generalized uncertainty principles?
  • RQ4To what extent do historical pendulum measurements constrain β₀, and what are their limitations?
  • RQ5Can the form of the modified commutator be probed directly using high-stability mechanical oscillators?

Key findings

  • The experiment establishes an upper limit of β₀ < 5×10⁶ for the 0.3 kg sapphire split-bar resonator, improving previous bounds by a factor of 6.
  • For the 10 mg quartz bulk acoustic wave resonator, the analysis yields a more stringent upper limit of β₀ < 4×10⁴.
  • Historical data from 1936 physical pendulum experiments by Atkinson suggest even stronger constraints on β₀, but the lack of precise frequency stability prevents reliable upper bound estimation.
  • Pendulum-based systems are limited to testing only a specific form of the modified commutator that depends on the mean momentum value.
  • Electro-mechanical oscillators enable direct testing of any form of the generalized uncertainty principle due to superior stability and control.
  • The amplitude-frequency effect serves as a robust observable for detecting quantum gravity corrections in mechanical systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.