[Paper Review] The Acquisition Camera System for SOXS at NTT
This paper presents the design and performance analysis of the Acquisition Camera System (CAM) for SOXS, a new spectrograph on the ESO NTT telescope. The CAM enables high-precision target acquisition, secondary guiding, and scientific photometry using a compact optical layout with a 3.5×3.5 arcmin field of view, 0.205 arcsec/pixel sampling, and limiting magnitudes down to r′ ≈ 20.4 in 20 seconds, achieving SNR=10 across SDSS bands with optimized throughput and image quality.
SOXS (Son of X-Shooter) will be the new medium resolution (R$\sim$4500 for a 1 arcsec slit), high-efficiency, wide band spectrograph for the ESO-NTT telescope on La Silla. It will be able to cover simultaneously optical and NIR bands (350-2000nm) using two different arms and a pre-slit Common Path feeding system. SOXS will provide an unique facility to follow up any kind of transient event with the best possible response time in addition to high efficiency and availability. Furthermore, a Calibration Unit and an Acquisition Camera System with all the necessary relay optics will be connected to the Common Path sub-system. The Acquisition Camera, working in optical regime, will be primarily focused on target acquisition and secondary guiding, but will also provide an imaging mode for scientific photometry. In this work we give an overview of the Acquisition Camera System for SOXS with all the different functionalities. The optical and mechanical design of the system are also presented together with the preliminary performances in terms of optical quality, throughput, magnitude limits and photometric properties.
Motivation & Objective
- To develop a high-efficiency, compact Acquisition Camera System (CAM) for the SOXS spectrograph on the ESO New Technology Telescope (NTT) to enable rapid target acquisition and secondary guiding.
- To ensure the CAM supports scientific-grade imaging and moderate high-speed photometry with high image quality and low noise.
- To achieve optimal optical performance across the optical and near-infrared (350–2000 nm) by integrating a pre-slit Common Path feeding system with relay optics and a calibrated filter wheel.
- To meet stringent mechanical and thermal stability requirements at La Silla Observatory, ensuring sub-arcsecond image quality under varying environmental conditions.
- To predict and validate limiting magnitudes for photometric observations using realistic sky and detector parameters, including quantum efficiency and read noise.
Proposed method
- The CAM employs a T-shaped aluminum 6061-T6 structure with 15 mm thick load-bearing walls for high stiffness, supporting the detector and optical components.
- A 60 mm diameter collimator lens on a 15 mm stroke linear stage (PI M-111.1DG1) acts as a re-focuser, with components secured using 3M 2216 adhesive spots.
- A folding mirror redirects the beam along the telescope axis, mounted with axial leaf springs and a spring retainer for stable alignment.
- A rotary filter wheel (PI M-116.DG) with up to nine filters is integrated, using a custom support to hold optical elements.
- The camera lens system consists of two doublets and two singlets (max 28 mm diameter), forming a f/3.6 system with a 434.15 mm focal length, mounted via radial holes for 3M 2216 adhesive bonding.
- Performance was predicted using a modified version of the Schaefe (1998) sensitivity algorithm, incorporating telescope parameters, detector QE (Andor iKon-M934), and sky conditions at La Silla (e.g., airmass=1.15, FWHM=0.8 arcsec, 10°C, 10% humidity).
Experimental results
Research questions
- RQ1What is the achievable limiting magnitude for the CAM system across SDSS bands (u′, g′, r′, i′, z′) at SNR=10 for various exposure times?
- RQ2How does the optical design of the CAM system ensure a 3.5×3.5 arcmin field of view with 0.205 arcsec/pixel sampling and diffraction-limited image quality?
- RQ3What is the impact of thermal and mechanical stability on image quality, particularly under temperature variations from 0°C to 20°C?
- RQ4How does the system maintain high throughput and low noise across the optical and near-infrared spectrum using a Common Path feeding architecture?
- RQ5What is the expected performance of the CAM for scientific photometry and high-speed imaging, given the detector’s read noise (2.9 e−) and quantum efficiency?
Key findings
- The CAM achieves a field of view of 3.5×3.5 arcminutes with a pixel scale of 0.205 arcsec/pixel, enabling high-precision target acquisition and secondary guiding.
- The system reaches limiting magnitudes of r′ ≈ 20.4 in 20 seconds (SNR=10) in the r′ band, with u′ band reaching r′ ≈ 19.1 in the same time.
- The predicted limiting magnitude in the z′ band is 17.4 in 15 seconds, demonstrating high sensitivity in the near-infrared.
- The optical design ensures a Strehl ratio above 0.95 across the field, with spot sizes of approximately 2 pixels (26.0 µm) at 20°C.
- The mechanical design using aluminum 6061-T6 and kinematic mounts ensures high stiffness and thermal stability, minimizing image shift under temperature variations.
- The system maintains high throughput with 80% filter peak transmission and a detector quantum efficiency profile consistent with the Andor iKon-M934 datasheet, supporting low-noise operation (RON = 2.9 e−).
Read this paper