Skip to main content
QUICK REVIEW

[Paper Review] The CAPTAIN Detector and Physics Program

The CAPTAIN Collaboration, H. Berns|arXiv (Cornell University)|Sep 6, 2013
Neutrino Physics ResearchPhysics and Astronomy9 references23 citations
TL;DR

The CAPTAIN experiment proposes a 5-ton liquid argon time-projection chamber (LArTPC) at Los Alamos National Laboratory to measure neutron and neutrino interactions in argon with high precision. Using laser calibration, photon detection, and beamlines at the SNS and NuMI, it enables first-of-its-kind measurements of low-energy neutrino cross-sections and neutron energy tagging, critical for supernova and long-baseline neutrino physics.

ABSTRACT

The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.

Motivation & Objective

  • To measure neutron interaction cross-sections in argon relevant to supernova burst neutrino detection and long-baseline neutrino oscillation experiments.
  • To develop and test neutron energy reconstruction and tagging techniques in a liquid argon TPC for improved total neutrino energy measurement.
  • To perform the first measurement of low-energy neutrino cross-sections on argon using a liquid argon TPC at the Spallation Neutron Source (SNS).
  • To validate calibration and detection strategies—especially laser calibration and photon detection—for future large-scale LArTPC detectors like those in LBNE.
  • To support the physics programs of LBNE by providing critical data on charged and neutral current interactions, de-excitation gamma tagging, and background suppression.

Proposed method

  • Deploy a 7,700-liter portable cryostat containing 5 tons of liquid argon with a 2,000-channel liquid argon TPC and a photon detection system.
  • Utilize laser calibration systems and optical windows to enable precise calibration of light yield and detector response.
  • Conduct high-intensity neutron running at the Los Alamos Neutron Science Center (LANSCE) to measure spallation product cross-sections and neutron energy deposition.
  • Perform low-intensity neutron and neutrino running at the SNS, using a stopped pion source to simulate supernova burst neutrinos with a 50 MeV endpoint spectrum.
  • Run at the NuMI beamline at Fermilab, including on-axis and off-axis configurations, to measure neutrino interactions in the 1–10 GeV range.
  • Use the prototype 1,000-channel LArTPC to test end-to-end systems and develop analysis techniques prior to full CAPTAIN deployment.

Experimental results

Research questions

  • RQ1What are the cross-sections of neutron interactions with argon in the energy range relevant to supernova burst neutrinos?
  • RQ2Can a liquid argon TPC accurately reconstruct neutron energy and detect de-excitation gamma rays from excited nuclear states in argon, chlorine, and potassium?
  • RQ3What is the energy resolution and background performance of a liquid argon TPC for low-energy neutrino interactions (<50 MeV) in a realistic surface environment?
  • RQ4How effective are laser calibration and photon detection systems in enabling precise tagging of neutrino interaction events in liquid argon?
  • RQ5What are the optimal detector configurations and shielding strategies for minimizing neutron backgrounds in long-baseline neutrino experiments?

Key findings

  • The CAPTAIN detector is expected to collect several thousand neutrino events per year at the SNS when sited within 10–30 meters of the target, enabling first measurements of low-energy neutrino cross-sections on argon.
  • The prototype LArTPC, with 1,000 channels, will allow early testing of calibration and analysis techniques, reducing risks for the full-scale detector.
  • Neutron data from the LANSCE beamline will provide critical measurements of spallation product cross-sections that mimic electron neutrino appearance signals in long-baseline experiments.
  • The SNS stopped pion source offers a well-characterized, broad-spectrum neutrino beam (up to 50 MeV) ideal for simulating supernova burst neutrinos.
  • The detector's photon detection system will enable tagging of de-excitation gamma rays from excited nuclear states in 40K, 39Ar, and 37Ar, crucial for background suppression.
  • The CAPTAIN program will provide essential data for the design and operation of the LBNE far detector, particularly for light collection and DAQ system specifications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.