[Paper Review] The COHERENT Experimental Program
The COHERENT experiment at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pioneered the first measurements of coherent elastic neutrino-nucleus scattering (CEvNS) on cesium iodide and argon using a high-intensity, high-purity neutrino beam. The program continues to advance precision tests of the Standard Model, searches for physics beyond the Standard Model—including dark matter, sterile neutrinos, and axion-like particles—using next-generation detectors and upgraded SNS beam power.
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
Motivation & Objective
- To measure coherent elastic neutrino-nucleus scattering (CEvNS) on multiple nuclear targets, including CsI and argon, to test the Standard Model and probe new physics.
- To search for accelerator-produced dark matter and sterile neutrinos using CEvNS detectors with enhanced sensitivity.
- To study inelastic neutrino-nucleus interactions and nuclear structure effects in low-energy neutrino scattering.
- To develop and deploy next-generation detectors—such as tonne-scale liquid argon TPCs, cryogenic scintillators, and high-purity germanium arrays—for improved physics reach.
- To leverage the SNS's high-quality, decay-at-rest neutrino beam with >99% DAR purity to minimize backgrounds and enable precise measurements.
Proposed method
- Utilizes the SNS's high-intensity, pulsed proton beam to produce neutrinos via pion decay at rest (DAR), yielding a clean, well-timed neutrino source with minimal background.
- Employs low-threshold, low-background detectors such as NaI(Tl), CsI, and high-purity germanium (HPGe) crystals to detect nuclear recoils from CEvNS with sub-keV energy thresholds.
- Applies the Standard Model prediction for CEvNS cross section: $\frac{d\sigma}{dT} = \frac{G_F^2 M}{2\pi} \left[ (G_V + G_A)^2 + (G_V - G_A)^2 \left(1 - \frac{T}{E_\nu}\right)^2 - (G_V^2 - G_A^2) \frac{MT}{E_\nu^2} \right]$, where $G_V$ and $G_A$ depend on neutron and proton content and nuclear form factors.
- Deploys advanced cryogenic and scintillation detection techniques, including cryogenic undoped CsI and liquid argon time-projection chambers (LAr TPCs), for improved energy resolution and background suppression.
- Uses active muon veto systems and deep underground shielding to reduce cosmic-ray and radioactive backgrounds.
- Employs precision calibration with radioactive sources and in-situ monitoring to ensure energy scale accuracy and detector stability.
Experimental results
Research questions
- RQ1What is the cross section of CEvNS on cesium iodide and argon, and does it agree with the Standard Model prediction?
- RQ2Can CEvNS measurements constrain non-standard interactions (NSIs) or new physics beyond the Standard Model?
- RQ3What is the sensitivity of CEvNS detectors to low-mass dark matter particles produced at the SNS?
- RQ4Can CEvNS data reveal evidence for sterile neutrinos or inelastic neutrino-nucleus scattering?
- RQ5How do nuclear form factors and quenching effects influence the response of different scintillating and semiconducting detectors to low-energy nuclear recoils?
Key findings
- COHERENT achieved the world’s first observation of CEvNS on cesium iodide in 2017, confirming the Standard Model prediction at the few-per-mille level.
- In 2020, COHERENT reported the first measurement of CEvNS on argon, demonstrating the feasibility of using noble liquids for low-energy neutrino detection.
- The collaboration has deployed a 2-tonne NaI(Tl) detector and a 18 kg high-purity germanium detector in Neutrino Alley, with data collected for flux normalization and background studies.
- The COHERENT program is developing a 750-kg liquid argon scintillation calorimeter (COH-Ar-750) and a 1-tonne NaI(Tl) detector (COH-NaI-2), both designed for high sensitivity to CEvNS and dark matter.
- A cryogenic undoped CsI scintillator (COH-CryoCsI-1) is under development with improved light yield and quenching factor characterization for enhanced energy resolution.
- The SNS is expected to reach 2 MW beam power by 2025, with a second target station planned for the 2030s, enabling a final power of 2.8 MW and significantly increased physics reach.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.