Skip to main content
QUICK REVIEW

[Paper Review] The COSmic Monopole Observer (COSMO)

S. Masi, E. S. Battistelli|arXiv (Cornell University)|Oct 23, 2021
Astrophysics and Star Formation StudiesPhysics and Astronomy19 references9 citations
TL;DR

The COSmic Monopole Observer (COSMO) is a cryogenic differential Fourier transform spectrometer designed to detect sub-ppm spectral distortions in the Cosmic Microwave Background (CMB) from Antarctica and future stratospheric balloon flights. By using fast sky-dip modulation to separate atmospheric emission from the CMB monopole, COSMO aims to measure the y-distortion with a sensitivity of $ y = (1.70 \pm 0.28) \times 10^{-6} $, providing critical insights into pre-recombination physics and cosmic energy release.

ABSTRACT

The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($

Motivation & Objective

  • To detect sub-ppm spectral distortions in the CMB, particularly the y-distortion from late-time energy release in the universe.
  • To develop a sub-orbital pathfinder experiment capable of measuring CMB spectral distortions with high sensitivity, overcoming atmospheric and instrumental systematics.
  • To validate fast sky-dip modulation techniques for separating atmospheric emission from the isotropic CMB component in ground-based observations.
  • To prepare for future space-based missions by testing instrumentation and data analysis methods in near-space environments.
  • To provide independent constraints on cosmic reionization, recombination physics, and dark matter through spectral distortion signatures.

Proposed method

  • COSMO employs a Martin Puplett interferometer configuration with two input ports: one for the sky and one for a cryogenic reference blackbody, enabling differential measurement of spectral brightness.
  • The instrument uses a moving roof mirror to scan optical path difference, generating interferograms that are Fourier-transformed to retrieve the sky spectrum.
  • A fast sky-dip technique is applied to modulate atmospheric emission, allowing its spectral signature to be separated from the CMB monopole and instrumental background.
  • Calibration is performed using an external blackbody source at known temperature, enabling determination of the instrument’s responsivity and spectral efficiency.
  • The data analysis employs an Internal Linear Combination (ILC) method to isolate the Compton-y distortion by subtracting thermal dust emission and CMB anisotropies.
  • For balloon-borne operation, a thin (25 μm) cryostat window is used to reduce thermal emission, and the instrument is expected to operate in photon-noise-limited conditions.

Experimental results

Research questions

  • RQ1Can a ground-based FTS experiment detect the y-distortion in the CMB with sub-ppm sensitivity despite atmospheric and instrumental systematics?
  • RQ2How effectively can fast sky-dip modulation suppress atmospheric emission fluctuations and isolate the isotropic CMB component?
  • RQ3What is the expected sensitivity of COSMO to spectral distortions after one year of integration at Dome-C, Antarctica?
  • RQ4Can a stratospheric balloon platform significantly reduce residual atmospheric emission and improve sensitivity compared to ground-based operations?
  • RQ5What instrumental and data analysis strategies are required to achieve photon-noise-limited performance in sub-orbital CMB spectral distortion measurements?

Key findings

  • COSMO is expected to measure the y-distortion with a value of $ y = (1.70 \pm 0.28) \times 10^{-6} $ after one year of integration at Dome-C, Antarctica.
  • The instrument’s fast sky-dip technique effectively separates atmospheric emission from the CMB monopole, reducing systematic errors from atmospheric fluctuations.
  • The ground-based implementation achieves a signal-to-noise ratio sufficient to detect the largest spectral distortion (y-distortion) with high confidence.
  • The balloon-borne version is forecast to achieve a signal-to-noise ratio greater than 10 for the y-distortion after 15 days of flight, with photon noise as the dominant limit.
  • The use of a thin (25 μm) cryostat window on the balloon platform reduces thermal emission by a factor of ~100, significantly improving sensitivity.
  • The ILC method with 0th-order thermal dust subtraction provides the best reconstruction of the isotropic y-distortion, minimizing residual foreground contamination.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.