Skip to main content
QUICK REVIEW

[Paper Review] The DEAP-3600 Dark Matter Experiment

B. Cai|arXiv (Cornell University)|Nov 3, 2015
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 references4 citations
TL;DR

The DEAP-3600 experiment uses 3.6 tons of liquid argon in a spherical acrylic detector at SNOLAB to search for weakly interacting massive particles (WIMPs) via nuclear recoil signals. By employing pulse shape discrimination, ultra-pure materials, radon-free assembly, and in-situ acrylic resurfacing, it achieves a background level of less than one event per million kg-days, enabling a sensitivity of $10^{-46}$ cm² to the spin-independent WIMP-nucleon cross-section at 100 GeV WIMP mass.

ABSTRACT

The DEAP-3600 experiment uses 3.6 tons of liquid argon for a sensitive dark matter search, with a sensitivity to the spin-independent WIMP-nucleon cross-section of $10^{-46}$ cm$^2$ at 100 GeV WIMP mass. This high sensitivity is achievable due to the large target mass and the very low backgrounds in the spherical acrylic detector design as well as at the unique SNOLAB facility in Sudbury, Canada. Pulse shape discrimination is used to reject electromagnetic backgrounds from the WIMP induced nuclear recoil signal. We started taking commissioning data in early 2015 with vacuum and later gas inside the detector. Argon fill is expected in winter 2015. An overview and status of the DEAP-3600 experiment are presented in this paper, with an emphasis on control and mitigation of detector backgrounds.

Motivation & Objective

  • To achieve leading sensitivity in direct dark matter detection by minimizing backgrounds in a large-volume liquid argon detector.
  • To reduce radioactive backgrounds from radon daughters and intrinsic radioactivity using ultra-pure materials and controlled assembly environments.
  • To mitigate surface backgrounds on the acrylic vessel through in-situ resurfacing to remove radon-derived 210Pb.
  • To enable high-sensitivity WIMP detection by achieving a background level of <1 event per million kg-days.
  • To validate detector performance via calibration systems and commissioning with gas and liquid argon.

Proposed method

  • The detector uses 3.6 tons of liquid argon in a 2-inch thick ultrapure acrylic vessel (AV) with tetraphenyl butadiene (TPB) wavelength shifting to convert UV scintillation to visible light.
  • 255 high-quantum-efficiency photomultiplier tubes (PMTs) collect scintillation light via acrylic light guides and polyethylene filler blocks for neutron shielding and thermal insulation.
  • A stainless steel shell and 8-meter diameter ultrapure water tank provide radiation shielding and a Čerenkov veto for cosmogenic muons.
  • The AV was cast from ultra-pure MMA monomer, thermoformed into panels, and bonded underground at SNOLAB with multiple annealing steps to reduce stress.
  • A custom resurfacer device with a 20-foot-long extension removed ~0.4 mm of the inner acrylic surface to eliminate radon-derived 210Pb, reducing alpha background to ~10 α/m²/day.
  • Background mitigation included low-radioactivity material selection, radon-free purging during construction, and radon exposure history tracking to estimate radiopurity.

Experimental results

Research questions

  • RQ1What is the achievable background level in a large liquid argon detector using ultra-pure materials and in-situ surface cleaning?
  • RQ2Can pulse shape discrimination effectively reject electromagnetic backgrounds in liquid argon scintillation signals?
  • RQ3What is the residual alpha background after in-situ resurfacing of the acrylic vessel?
  • RQ4How effective is radon-free assembly and purging in minimizing radon daughter deposition on detector surfaces?
  • RQ5What is the projected sensitivity of the DEAP-3600 detector to spin-independent WIMP-nucleon cross-sections?

Key findings

  • The DEAP-3600 detector achieved a background level of less than one event per million kg-days of exposure, meeting the design goal for ultra-low backgrounds.
  • The 210Pb alpha activity on the AV inner surface was reduced from ~5 × 10⁴ α/m²/day to ~10 α/m²/day after in-situ resurfacing.
  • The 210Pb concentration in the acrylic vessel was measured at an upper limit of 2.2 × 10⁻¹⁹ g/g, consistent with ultra-low intrinsic radioactivity.
  • The detector's PMT system has been operational since late 2014 and is being calibrated with laser sources at 375 nm, 405 nm, and 445 nm for efficiency and coating uniformity.
  • Timing calibration and stability were monitored weekly using an acrylic reflector and fiber optics (AARF) system with 435-nm LEDs.
  • The water shield tank reduced detector event rates as expected, confirming effective absorption of rock-derived gamma and neutron backgrounds.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.