Skip to main content
QUICK REVIEW

[Paper Review] The difference between Faradaic and non-Faradaic electrode processes

P. M. Biesheuvel, S. Porada|arXiv (Cornell University)|Sep 9, 2018
Membrane-based Ion Separation TechniquesEngineering15 references32 citations
TL;DR

This paper clarifies the distinction between Faradaic and non-Faradaic electrode processes, demonstrating that broad peaks in cyclic voltammetry (CV) do not indicate Faradaic behavior. Using nickel hexacyanoferrate (NiHCF), the authors show via experimental CV and RC network modeling with the extended Frumkin isotherm that capacitance-dependent voltage response explains peak shapes, proving the process is non-Faradaic despite redox-like behavior.

ABSTRACT

Both Faradaic and non-Faradaic processes can take place at an electrode. The difference between the two processes is clearly discussed in several classical sources, starting with Grahame (1952). However, later reference to charge transfer across the metal-solution interface as a defining feature of a Faradaic process, has led to ambiguities. Following Grahame, in a Faradaic process, charged particles transfer across the electrode, from one bulk phase to another. Thus, in a Faradaic process, after applying a constant current, the electrode charge, voltage and composition go to constant values. Instead, in a non-Faradaic (capacitive) process, charge is progressively stored. We characterize the intercalation material nickel hexacyanoferrate by two electrochemical methods and compare with theory. Data for the capacitance of this material is well described by the extended Frumkin isotherm. This data, and the correspondence with theory, demonstrates that this is a capacitive material and ion and charge storage in this material a non-Faradaic electrode process. Cyclic Voltammetry (CV) diagrams for this material have broad peaks for certain potential windows, and rectangular shapes for other conditions, both experimentally and in theoretical calculations based on a RC network model that includes how capacitance is a function of charge. Measured and predicted CV diagrams are in perfect agreement with one another. This shows that (broad) peaks in CV diagrams do not establish whether an electrode material is Faradaic or not.

Motivation & Objective

  • To resolve long-standing ambiguity in distinguishing Faradaic and non-Faradaic electrode processes based on experimental response to current.
  • To challenge the common misconception that broad peaks in cyclic voltammetry (CV) indicate Faradaic mechanisms.
  • To demonstrate that intercalation materials like NiHCF exhibit non-Faradaic behavior through capacitance-dependent voltage response.
  • To validate a simple RC network model incorporating the extended Frumkin isotherm to quantitatively reproduce experimental CV shapes across varying potential windows.

Proposed method

  • Experimental characterization of NiHCF using cyclic voltammetry (CV) across multiple potential windows and scan rates.
  • Application of the extended Frumkin isotherm to model electrode potential as a function of intercalation degree (ϑ), incorporating ion-ion interactions (g′ ≈ -3.5).
  • Development of an RC network model where capacitance C is a function of charge (via σ = σ_max · ϑ), and resistance R is constant.
  • Theoretical CV curves generated by solving the time-dependent charge balance: dΣ/dt = I, with V_total = V_res + V_cap.
  • Fitting of model parameters (g′ and dimensionless P-factor) to match experimental CVs across different voltage windows.
  • Use of the relation C = −∂Σ/∂V_cap to derive capacitance from the extended Frumkin equation, enabling realistic voltage-capacitance dependence.

Experimental results

Research questions

  • RQ1Can broad peaks in cyclic voltammetry be attributed to Faradaic processes, or do they arise from non-Faradaic capacitance behavior?
  • RQ2To what extent does the capacitance of intercalation materials like NiHCF vary with charge, and how does this affect CV shape?
  • RQ3Can a simple RC network model with voltage-dependent capacitance reproduce experimentally observed CV profiles for NiHCF?
  • RQ4Is the observed correspondence between theory and experiment sufficient to conclude that NiHCF exhibits non-Faradaic charge storage?
  • RQ5How does the P-factor (proportional to scan rate × resistance × mass × charge capacity / V_T²) influence the shape of CV curves in this system?

Key findings

  • Broad peaks in CV diagrams of NiHCF are not indicative of Faradaic processes but result from the non-monotonic capacitance behavior, which peaks at intermediate charge states.
  • The capacitance of NiHCF decreases at the extremes of its charging range, as predicted by the extended Frumkin isotherm with g′ ≈ -3.5.
  • Theoretical CV curves generated with the RC model and voltage-dependent capacitance match experimental data perfectly across five different potential windows.
  • The model reproduces both rectangular CVs (at small potential windows) and broad peaks (at large windows), demonstrating that peak shape is a consequence of capacitance variation, not Faradaic kinetics.
  • The P-factor, a dimensionless parameter combining scan rate, resistance, mass, and maximum charge, was fitted to 20 (800 mV), 4 (100 mV), and 2 (50 mV) for different voltage windows, confirming model consistency.
  • The study concludes that NiHCF is a non-Faradaic (capacitive) material, with charge storage occurring via ion insertion without net electron transfer across the interface, in line with Grahame’s original definition.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.