TL;DR

This study demonstrates that measuring cosmic ray muon momentum significantly enhances the detection and differentiation of shielded special nuclear materials (SNM), such as HEU, LEU, and plutonium, even behind 30 cm of lead shielding. Using Monte Carlo simulations, the authors show that momentum measurement enables >3σ identification accuracy, reducing required measurement time by a factor of 3–4 compared to momentum-agnostic methods.

ABSTRACT

Recently, cosmic ray muons have been considered as a potential high energy radiation probe for monitoring and interrogation of dense, well-shielded special nuclear materials (SNM). Due to their high-penetrative nature, cosmic ray muons can easily penetrate shielded nuclear materials with minimal absorption and with leaving the target objects intact. However, despite the potential benefits from using cosmic ray muons for SNM monitoring, their widespread application has been limited for various reasons, including relatively low cosmic ray muon flux at sea level and the difficulty of measuring muon momentum in the field which can increase resolution and reduce measurement time. In this work, we explore in detail the effect of cosmic ray muon momentum measurement, focusing specifically on SNM monitoring applications. Three different types of SNMs (HEU, LEU, and Pu) surrounded by lead shielding with five different thicknesses (0, 5, 10, 20, and 30 cm), are analyzed using Monte Carlo simulation for three momentum measurement resolution levels (perfect, limited, and absent). 1000 muons were generated in the simulation which translates to 4 minutes of measurement time for a standard cargo container. We found that it is possible to identify and separate HEU, LEU, and Pu with high accuracy (> 3 s.d.) when using muon momentum measurement (perfect and limited) even when 30 cm-thick lead shielding was used. Currently, it is not possible to identify or separate the SNMs with 30 cm thick lead shielding without muon momentum knowledge. Our results show that the effect of measuring muon momentum can be significant and can result in reduced measurement times by a factor of 3 to 4 and/or improved monitoring and imaging resolution.

Motivation & Objective

  • To evaluate the impact of cosmic ray muon momentum measurement on the detection and identification of shielded special nuclear materials (SNM).
  • To address the challenge of monitoring well-shielded SNM, particularly in cargo containers, where traditional radiation probes are ineffective.
  • To assess whether momentum measurement can overcome limitations of low muon flux and poor resolution in field applications.
  • To determine the minimum momentum resolution required for reliable SNM differentiation under realistic shielding conditions.

Proposed method

  • Monte Carlo simulations were used to model cosmic ray muon interactions with three SNM types: highly enriched uranium (HEU), low enriched uranium (LEU), and plutonium (Pu).
  • Five lead shielding thicknesses (0, 5, 10, 20, and 30 cm) were simulated to assess performance under increasing shielding conditions.
  • Three momentum measurement resolution levels were evaluated: perfect, limited, and absent, to isolate the effect of momentum resolution.
  • 1000 muons were simulated per run, corresponding to approximately 4 minutes of measurement time for a standard cargo container.
  • The simulation tracked muon trajectories and energy loss to infer material composition via scattering and absorption characteristics.
  • Statistical analysis was applied to determine the separation confidence level (in standard deviations) between SNM types under different conditions.

Experimental results

Research questions

  • RQ1Can muon momentum measurement enable reliable identification of HEU, LEU, and Pu behind thick lead shielding?
  • RQ2How does the accuracy of SNM differentiation change when muon momentum is measured with limited resolution versus not measured at all?
  • RQ3What is the minimum measurement time required to achieve high-confidence SNM identification when momentum is measured?
  • RQ4To what extent does momentum measurement improve imaging resolution in muon tomography of shielded SNM?
  • RQ5Can 30 cm of lead shielding be effectively penetrated and analyzed using muon momentum data for SNM monitoring?

Key findings

  • Muon momentum measurement enables the identification and separation of HEU, LEU, and Pu with high accuracy (>3σ) even when shielded by 30 cm of lead.
  • Without momentum measurement, it is not possible to identify or separate SNMs behind 30 cm of lead shielding.
  • The use of momentum measurement reduces required measurement time by a factor of 3 to 4 compared to momentum-agnostic methods.
  • Even with limited momentum resolution, SNM differentiation remains feasible and accurate under thick shielding.
  • Perfect momentum measurement provides the highest resolution and confidence, but practical limited-resolution systems still achieve robust performance.
  • The results demonstrate that momentum measurement is a critical enabler for field-deployable muon-based SNM monitoring systems.