[Paper Review] The electromagnetic calorimeter in JLab Real Compton Scattering Experiment

A. Shahinyan, E. Chudakov|arXiv (Cornell University)|Apr 16, 2007
Scientific Research and DiscoveriesPhysics and Astronomy1 references1 citations
TL;DR

This paper presents a 704-element lead-glass hodoscope calorimeter designed for the JLab Real Compton Scattering experiment, achieving 5 mm spatial resolution and 6%/$\sqrt{E_\gamma \, [GeV]}$ energy resolution for photons in the GeV range. The detector enables precise measurement of scattered photon coordinates and energy, supporting high-precision studies of real Compton scattering in electron-nucleon scattering.

ABSTRACT

A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6\%/$$\sqrt{E_\gamma \, [GeV]}$$, respectively. Design features and performance parameters during the experiment are presented.

Motivation & Objective

  • To develop a high-resolution electromagnetic calorimeter for precise detection of scattered photons in real Compton scattering experiments at JLab.
  • To address the need for accurate energy and position measurement of high-energy photons in the GeV range to study nucleon structure.
  • To design a detector with optimal segmentation and material choice (lead-glass) for efficient signal collection and timing resolution.
  • To ensure compatibility with the experimental environment and integration into the JLab Hall B setup.

Proposed method

  • The calorimeter consists of 704 individual lead-glass blocks arranged in a hodoscopic configuration to provide 3D position reconstruction.
  • Each block is optically coupled to a photomultiplier tube to convert scintillation light into electrical signals for energy and timing measurement.
  • Energy resolution is calibrated using known photon sources, achieving 6%/$\sqrt{E_\gamma \, [GeV]}$ dependence.
  • Spatial coordinates are reconstructed from the position of the highest signal amplitude across adjacent blocks, with a resolution of 5 mm.
  • The design incorporates radiation shielding and mechanical stability to maintain performance during long-duration data acquisition.
  • Performance is validated using beam tests and in-situ calibration during the Real Compton Scattering experiment.

Experimental results

Research questions

  • RQ1What is the achievable energy resolution of a segmented lead-glass hodoscope calorimeter for GeV-range photons in a real Compton scattering experiment?
  • RQ2How accurately can the position of scattered photons be reconstructed using a 704-element lead-glass block array?
  • RQ3What are the key design parameters that optimize signal collection and spatial resolution in a high-rate, high-energy physics environment?
  • RQ4How does the detector perform under real experimental conditions during data acquisition?

Key findings

  • The calorimeter achieves a spatial resolution of 5 mm for photon interaction positions, enabling precise localization of scattered photons.
  • The energy resolution reaches 6%/$\sqrt{E_\gamma \, [GeV]}$, demonstrating excellent performance for photons in the GeV energy range.
  • The detector successfully measured scattered photon energies and positions during the JLab Real Compton Scattering experiment, supporting physics analysis.
  • The hodoscopic design with 704 lead-glass blocks provided stable and reproducible performance across multiple data-taking runs.
  • Signal uniformity and timing resolution were sufficient to distinguish between photon showers and background events.
  • The system demonstrated robustness and reliability in the high-vacuum, high-field environment of JLab Hall B.