[Paper Review] The Fully Convolutional Transformer for Medical Image Segmentation
The paper proposes the Fully Convolutional Transformer (FCT), a novel, compact, and fully convolutional transformer architecture for medical image segmentation that combines convolutional attention with a multi-resolution dilated convolutional Wide-Focus module to capture long-range dependencies and hierarchical features. FCT achieves state-of-the-art performance across multiple datasets—outperforming existing models by up to 4.4% in Dice score—while using up to five times fewer parameters than competitors like nnUNet and TransUNet.
We propose a novel transformer model, capable of segmenting medical images of varying modalities. Challenges posed by the fine grained nature of medical image analysis mean that the adaptation of the transformer for their analysis is still at nascent stages. The overwhelming success of the UNet lay in its ability to appreciate the fine-grained nature of the segmentation task, an ability which existing transformer based models do not currently posses. To address this shortcoming, we propose The Fully Convolutional Transformer (FCT), which builds on the proven ability of Convolutional Neural Networks to learn effective image representations, and combines them with the ability of Transformers to effectively capture long-term dependencies in its inputs. The FCT is the first fully convolutional Transformer model in medical imaging literature. It processes its input in two stages, where first, it learns to extract long range semantic dependencies from the input image, and then learns to capture hierarchical global attributes from the features. FCT is compact, accurate and robust. Our results show that it outperforms all existing transformer architectures by large margins across multiple medical image segmentation datasets of varying data modalities without the need for any pre-training. FCT outperforms its immediate competitor on the ACDC dataset by 1.3%, on the Synapse dataset by 4.4%, on the Spleen dataset by 1.2% and on ISIC 2017 dataset by 1.1% on the dice metric, with up to five times fewer parameters. Our code, environments and models will be available via GitHub.
Motivation & Objective
- To address the limitations of existing transformer-based models in medical image segmentation, which lack the fine-grained feature learning capability of UNet.
- To develop a fully convolutional transformer that effectively captures long-range semantic dependencies and hierarchical global context in medical images.
- To create a lightweight, accurate, and robust model that surpasses state-of-the-art performance without requiring pretraining.
- To integrate convolutional operations with self-attention mechanisms in a way that eliminates the need for positional encoding and patch tokenization.
Proposed method
- The FCT employs a novel Fully Convolutional Transformer layer composed of two main components: a Convolutional Attention module and a Wide-Focus module.
- The Convolutional Attention module uses depthwise separable convolutions to generate overlapping, spatially aware patches, replacing standard patch embedding and eliminating the need for positional encoding.
- The Wide-Focus module applies multi-resolution dilated convolutions with increasing dilation rates across three branches to capture hierarchical local-to-global features.
- The model processes inputs in two stages: first, it learns long-range semantic dependencies via the Convolutional Attention module, then it builds hierarchical global representations using the Wide-Focus module.
- Skip connections are used from encoder to decoder, following the UNet design, to preserve spatial details and improve feature propagation.
- The model is trained end-to-end with standard data augmentation and inference is performed using sliding window inference with post-processing to average overlapping predictions.
Experimental results
Research questions
- RQ1Can a fully convolutional transformer architecture outperform existing CNN and transformer-based models in medical image segmentation without pretraining?
- RQ2How does the integration of convolutional attention and multi-resolution dilated convolutions affect performance in capturing long-range and fine-grained features?
- RQ3What is the optimal configuration of the Wide-Focus module in terms of number of branches and dilation rates for medical image segmentation?
- RQ4To what extent do skip connections contribute to performance in the proposed FCT architecture?
- RQ5Can a compact transformer-based model achieve state-of-the-art results with significantly fewer parameters than existing models?
Key findings
- FCT outperforms all existing transformer and CNN-based models on the ACDC dataset by 1.3% in Dice score, without pretraining.
- On the Synapse dataset, FCT achieves a 4.4% improvement in Dice score over its immediate competitor, with 5× fewer parameters than nnUNet.
- On the Spleen dataset, FCT improves Dice score by 1.2% compared to the next best model, demonstrating robustness across different anatomical structures.
- On the ISIC 2017 dataset, FCT achieves a 1.1% higher Dice score than the closest competitor, confirming its generalization across diverse image modalities.
- On the ACDC Post-2017-MICCAI-Challenge online test set, FCT sets a new state-of-the-art performance, outperforming large ensemble models and nnUNet with only 31.7 million parameters.
- Ablation studies confirm that skip connections and the optimal configuration of the Wide-Focus module (three branches with linearly increasing dilation rates) are critical for peak performance.