[Paper Review] The HARPS polarimeter

Frans Snik, O. Kochukhov|arXiv (Cornell University)|Oct 3, 2010
Stellar, planetary, and galactic studiesPhysics and Astronomy1 references4 citations
TL;DR

The HARPS polarimeter upgrades the HARPS spectrograph at ESO’s 3.6-m telescope in La Silla to perform high-resolution full-Stokes spectropolarimetry with a sensitivity of ~10⁻⁵, using dual-beam polarimetry and wave plate modulators. Commissioning data show no significant instrumental polarization, and the instrument successfully detects no strong magnetic signals in α Cen A, indicating lower magnetic activity than the Sun despite similar spectral type and age.

ABSTRACT

We recently commissioned the polarimetric upgrade of the HARPS spectrograph at ESO's 3.6-m telescope at La Silla, Chile. The HARPS polarimeter is capable of full Stokes spectropolarimetry with large sensitivity and accuracy, taking advantage of the large spectral resolution and stability of HARPS. In this paper we present the instrument design and its polarimetric performance. The first HARPSpol observations show that it can attain a polarimetric sensitivity of ~10^-5 (after addition of many lines) and that no significant instrumental polarization effects are present.

Motivation & Objective

  • To extend HARPS spectrograph capabilities to full-Stokes spectropolarimetry for magnetic field studies of stars.
  • To achieve high polarimetric sensitivity (~10⁻⁵) using beam-exchange techniques and dual-beam modulation.
  • To minimize instrumental polarization effects through optimized optical design and wave plate selection.
  • To enable Zeeman-Doppler and magnetic Doppler imaging of unresolved stellar surfaces.
  • To provide a southern hemisphere complement to existing high-resolution spectropolarimeters like ESPaDOnS.

Proposed method

  • The polarimeter uses a custom Foster prism beam-splitter to separate orthogonal linear polarizations into two fibers, with achromatic splitting at 135° and extinction ratios of 10⁴–10⁶.
  • A superachromatic quarter-wave plate (QWP) and half-wave plate (HWP) modulate circular and linear polarization states, respectively, with ±3° and ±2° accuracy across 380–690 nm.
  • Modulation is performed via synchronized rotation of QWP and HWP in 90° and 22.5° steps, enabling double-ratio demodulation to suppress systematic errors.
  • Beam defocus from polarimeter insertion is compensated by moving the telescope’s secondary mirror backward by ~2 mm.
  • Polarization spectra are demodulated using the double-ratio method, and null spectra are computed to detect false signals.
  • Standard HARPS data reduction (dark subtraction, flat-fielding, wavelength calibration) is applied, with additional calibration for polarization cross-talk.

Experimental results

Research questions

  • RQ1Can the HARPS polarimeter achieve a polarimetric sensitivity of ~10⁻⁵ in full-Stokes spectropolarimetry?
  • RQ2Does the instrument introduce significant instrumental polarization or cross-talk between Stokes parameters?
  • RQ3How does the polarimetric performance of HARPSpol compare to calibrated data from ESPaDOnS on a standard magnetic star?
  • RQ4Can HARPSpol detect magnetic fields in a solar twin like α Cen A, given its known magnetic activity?
  • RQ5What is the impact of the atmospheric dispersion corrector (ADC) on broad-band instrumental polarization in the polarimetric measurements?

Key findings

  • The HARPS polarimeter achieves a polarimetric sensitivity of ~10⁻⁵ in the LSD profile after co-addition of spectral lines, sufficient to detect magnetic fields down to ~0.1 G.
  • No significant instrumental polarization effects were detected in commissioning data, confirming the instrument’s high accuracy and low systematic errors.
  • HARPSpol data on γ Equ match calibrated ESPaDOnS data well, indicating negligible cross-talk and high reliability despite lack of polarization calibration optics.
  • The observed Stokes V profile for α Cen A shows no Zeeman effect signal down to 0.1 G, suggesting it is significantly less magnetically active than the Sun.
  • The larger spectral resolution of HARPS (R = 110,000) results in stronger polarization signals compared to ESPaDOnS (R = 65,000), confirming enhanced sensitivity.
  • Broad-band instrumental polarization from the ADC does not affect line polarization analyses, and no significant fringing or defocus issues were observed.