[Paper Review] The Impact of Interpixel Capacitance on WFIRST PSFs
This paper investigates how interpixel capacitance (IPC) in WFIRST's near-infrared CMOS hybrid detectors distorts point-spread functions (PSFs), increasing PSF size by approximately 5% and altering shape. Using forward-simulation from physical principles, it derives a linear fitting formula to quantify PSF uncertainty due to IPC variability, critical for weak lensing survey accuracy.
Unlike optical CCDs, near-infrared detectors, which are based on CMOS hybrid readout technology, typically suffer from electrical crosstalk between the pixels. The interpixel capacitance (IPC) responsible for the crosstalk affects the point-spread function (PSF) of the telescope, increasing the size and modifying the shape of all objects in the images while correlating the Poisson noise. Upcoming weak lensing surveys that use these detectors, such as WFIRST, place stringent requirements on the PSF size and shape (and the level at which these are known), which in turn must be translated into requirements on IPC. To facilitate this process, we present a first study of the effect of IPC on WFIRST PSF sizes and shapes. Realistic PSFs are forward-simulated from physical principles for each WFIRST bandpass. We explore how the PSF size and shape depends on the range of IPC coupling with pixels that are connected along an edge or corner; for the expected level of IPC in WFIRST, IPC increases the PSF sizes by ∼5\%. We present a linear fitting formula that describes the uncertainty in the PSF size or shape due to uncertainty in the IPC, which could arise for example due to unknown time evolution of IPC as the detectors age or due to spatial variation of IPC across the detector. We also study of the effect of a small anisotropy in the IPC, which further modifies the PSF shapes. Our results are a first, critical step in determining the hardware and characterization requirements for the detectors used in the WFIRST survey.
Motivation & Objective
- To quantify the impact of interpixel capacitance (IPC) on the point-spread function (PSF) in WFIRST's near-infrared detectors.
- To determine how IPC affects PSF size and shape, which are critical for weak gravitational lensing surveys.
- To model the uncertainty in PSF measurements arising from unknown or varying IPC levels across the detector or over time.
- To assess the influence of anisotropic IPC on PSF shape distortions.
- To provide a foundation for setting hardware and calibration requirements for WFIRST detectors based on PSF stability needs.
Proposed method
- Forward-simulating realistic PSFs from first physical principles for each WFIRST bandpass.
- Modeling IPC coupling between pixels along edges and corners to simulate crosstalk effects.
- Using a linear fitting formula to relate uncertainty in IPC to uncertainty in PSF size and shape.
- Analyzing the effect of small anisotropy in IPC on PSF shape, particularly in the context of weak lensing systematics.
- Evaluating PSF size and shape changes across the expected range of IPC values in WFIRST detectors.
- Quantifying the combined impact of IPC on PSF size and shape, including noise correlation effects.
Experimental results
Research questions
- RQ1How does interpixel capacitance (IPC) affect the size and shape of the PSF in WFIRST's near-infrared detectors?
- RQ2To what extent does IPC increase PSF size, and how does this vary across different WFIRST bandpasses?
- RQ3How does uncertainty in IPC—due to aging or spatial variation—affect the accuracy of PSF measurements?
- RQ4What is the impact of anisotropic IPC on PSF shape, and how does it contribute to systematics in weak lensing surveys?
- RQ5Can a linear model accurately describe the relationship between IPC uncertainty and PSF uncertainty?
Key findings
- Interpixel capacitance (IPC) increases the PSF size in WFIRST by approximately 5% at the expected IPC levels.
- The PSF shape is systematically modified by IPC, with additional distortions introduced by small anisotropies in the coupling.
- A linear fitting formula accurately describes the uncertainty in PSF size or shape due to uncertainty in IPC parameters.
- The uncertainty in PSF measurements due to IPC variability must be accounted for in weak lensing calibration, particularly for time-evolving or spatially non-uniform IPC.
- The study provides a quantitative framework to translate PSF stability requirements into hardware and characterization constraints for WFIRST detectors.
- The results highlight the critical need for precise IPC characterization and monitoring to meet the stringent PSF requirements of weak lensing surveys.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.