TL;DR

The KLASH proposal presents a search for galactic axions with a mass of approximately 0.2 μeV using a 50 m³ resonant cavity cooled to 4 K and placed within the 0.6 T superconducting magnet of the KLOE experiment at INFN Frascati. By leveraging the existing infrastructure and achieving a sensitivity of $6 \times 10^{-17}$ GeV⁻¹ on the axion-photon coupling $g_{a\gamma\gamma}$, the experiment can probe the KSVZ and DFSZ models of QCD axions.

ABSTRACT

We propose a search of galactic axions with mass about 0.2 microeV using a large volume resonant cavity, about 50 m^3, cooled down to 4 K and immersed in a moderate axial magnetic field of about 0.6 T generated inside the superconducting magnet of the KLOE experiment located at the National Laboratory of Frascati of INFN. This experiment, called KLASH (KLoe magnet for Axion SearcH) in the following, has a potential sensitivity on the axion-to-photon coupling, g_agg, of about 6x10^-17 GeV-1, reaching the region predicted by KSVZ and DFSZ models of QCD axions.

Motivation & Objective

  • To search for galactic axions in the 0.2 μeV mass range using a large-volume resonant cavity.
  • To achieve sensitivity to the axion-photon coupling $g_{a\gamma\gamma}$ at the level predicted by the KSVZ and DFSZ models of QCD axions.
  • To utilize the existing KLOE superconducting magnet and cryogenic infrastructure to enable a low-cost, high-sensitivity axion search.
  • To demonstrate that a large-volume cavity in a moderate magnetic field can achieve competitive sensitivity compared to smaller, high-field experiments like ADMX.

Proposed method

  • The experiment uses a 50 m³ copper-walled TM₀₁₀ resonant cavity cooled to 4 K to enhance the quality factor and reduce thermal noise.
  • The cavity is placed inside the 0.6 T axial magnetic field of the KLOE superconducting solenoid, enabling axion-to-photon conversion via the Primakoff effect.
  • The signal power is calculated using the standard haloscope formula, with $P_{\text{sig}} \propto \omega_c B^2 V Q_L$, where $\omega_c$ is the cavity angular frequency, $B$ the magnetic field, $V$ the cavity volume, and $Q_L$ the loaded quality factor.
  • A cryogenic pre-amplification chain using a dc-SQUID at 200 mK and a HFET amplifier at 4.2 K is employed to achieve a system noise temperature below 1.4 K.
  • The cavity is tuned via mechanical rods to scan over a 40 MHz bandwidth in one year, with 5-minute integration times per frequency point.
  • Signal-to-noise ratio (SNR) is evaluated using the Dicke radiometer equation, with $\text{SNR} = P_{\text{sig}} / (k_B T_{\text{sys}}) \sqrt{\tau / \Delta\nu_a}$.

Experimental results

Research questions

  • RQ1Can a large-volume (50 m³) resonant cavity in a moderate 0.6 T magnetic field achieve sensitivity comparable to high-field experiments like ADMX?
  • RQ2What is the achievable sensitivity on the axion-photon coupling $g_{a\gamma\gamma}$ using the KLOE magnet infrastructure?
  • RQ3Can the existing cryogenic and magnetic systems of the KLOE experiment be repurposed for axion detection with minimal modifications?
  • RQ4What is the scan efficiency and total mass coverage achievable with mechanical tuning over a 2-year period?
  • RQ5Does the KLASH setup reach the sensitivity required to probe the KSVZ and DFSZ models of QCD axions?

Key findings

  • The KLASH experiment achieves a sensitivity of $6 \times 10^{-17}$ GeV⁻¹ on the axion-photon coupling $g_{a\gamma\gamma}$ at 90% confidence level, sufficient to probe the KSVZ and DFSZ models.
  • The signal power generated by axions is estimated at $1.6 \times 10^{-22}$ W for a 0.23 μeV axion mass, corresponding to a rate of 3,100 Hz in the cavity.
  • The experiment can scan a total mass range of approximately 0.16 μeV over one year of data taking, with a 40 MHz bandwidth, assuming 5-minute integration times and maximal tuning efficiency.
  • The system noise temperature is reduced to 1.2 K using a dc-SQUID amplifier at 1.5 K, enabling high-sensitivity detection of weak signals.
  • The factor $F = \omega_c B^2 V Q_L$ is comparable to ADMX and significantly larger than YWL, demonstrating the potential of large-volume cavities even at moderate field strengths.
  • The discovery potential of KLASH covers the preferred region of the KSVZ and DFSZ models, as shown in the coupling-mass plane, and overlaps with future experiments like IAXO and ALPSII.

Read this paper