[Paper Review] The "miniskirt" counter array at CDF-II
This paper details the design, modifications, testing, and installation of the 'miniskirt' scintillator counter arrays (MSX) for the CDF-II muon detector upgrade at Fermilab's Tevatron. To address space constraints that prevented full light-guide readout, wavelength-shifting (WLS) fibers were used with mirrored fiber ends and compact PMTs, achieving a timing resolution of ≤2.2 ns, sufficient for background discrimination in top quark and Higgs boson physics studies.
As a part of the CDF Upgrade for Run-II of the Tevatron collider, the azimuthal coverage of the muon detectors between pseudorapidities of 0.6 and 1.2 was completed by the insertion of stacks of drift chambers and scintillation counters, which came to be known as the "miniskirts" because they cover lower 90^o in azimuth. The design and construction of the miniskirts was rather complex and posed special problems because of its interference with the floor and the supports of the central detector. The original design parameters of the "miniskirt" scintillator counters for the CDF Muon System are presented and the modifications, testing and installation of these counters in the course of the CDF Upgrade Project are described in detail
Motivation & Objective
- To extend the azimuthal coverage of the CDF-II muon detector in the pseudorapidity range 0.6 < |η| < 1.2, which was incomplete in Run-I.
- To solve mechanical and spatial constraints that prevented full installation of light-guide readout systems in the miniskirt counters.
- To ensure timing resolution sufficient for background suppression in top quark and Higgs boson physics, particularly for $t\overline{t}$ and $J/\Psi \to \mu^+\mu^-$ decays.
- To develop and implement a reliable WLS fiber readout system with mirrored fiber ends to maximize light collection and minimize timing uncertainty.
- To calibrate and validate the performance of the MSX counters under cosmic ray and beam conditions prior to full installation.
Proposed method
- Used trapezoidal NE114 scintillator counters (15 mm thick) for the MSX, differing from the 20 mm thick CSX counters in the original design.
- Implemented dual-end readout using 2" EMI-type PMTs with curved Lucite light guides for standard MSX counters, but substituted with 1 mm-diameter Y11 WLS fibers for four counters (MSX′) due to space limitations.
- Applied BC-600 optical cement to bond WLS fiber ribbons (15-fiber bundles) to the long edges of the scintillators for efficient light collection.
- Evaporated aluminum coatings on the distal ends of WLS fibers to create 'mirrored' ends, achieving 70–90% reflection efficiency to enhance light collection.
- Calibrated PMTs using a fast blue LED (Nichia NSPB310A) to extract the calibration constant k (channels per photoelectron), and used this to determine counter sensitivity via $n_{pe} = (\overline{Q} - Q_o) / (k/A)$.
- Measured timing resolution using a cosmic muon telescope with two 15×15×2 cm³ scintillators, with TDCs and meantimers to assess time resolution and systematic effects.
Experimental results
Research questions
- RQ1How can effective muon detection be achieved in the 90° azimuthal gap of the CDF-II muon system at 0.6 < |η| < 1.2?
- RQ2What alternative readout method can be used when mechanical constraints prevent installation of standard light guides in the miniskirt counters?
- RQ3Can WLS fiber readout with mirrored ends achieve sufficient timing resolution for physics applications in Run-II?
- RQ4What is the achievable timing resolution of the final MSX′ design, and how does it compare to the requirement for background suppression?
- RQ5How do variations in signal timing across the length of the counter affect overall performance and system stability?
Key findings
- The WLS fiber readout system with mirrored fiber ends achieved a total timing resolution ($\sigma_{\text{tot}}$) of ≤2.2 ns, meeting the requirement for background discrimination in Run-II physics.
- The mean timing resolution, corrected for trigger counter uncertainty (1.1 ns), was found to be consistent across positions, with the highest uncertainty observed at the end furthest from the PMT (X3), likely due to Cherenkov light in the light guide.
- The use of aluminum-coated mirrored fiber ends increased light reflection efficiency to 70–90%, significantly improving signal collection compared to uncoated fibers.
- Counter sensitivity, measured via ADC response to cosmic muons, was determined using calibrated PMT parameters and the equation $n_{pe} = (\overline{Q} - Q_o) / (k/A)$, with results listed in Table 2.
- The final design, including WLS fiber readout and compact Hamamatsu H5783 PMTs, was successfully tested and installed, with three standard MSX sections already in operation by fall 2002.
- Occupancy monitoring via the YMON program confirmed stable operation under both beam and cosmic ray conditions, with no significant noise or gain instability observed.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.