Skip to main content
QUICK REVIEW

[Paper Review] The New Muon g-2 experiment at Fermilab

G. Venanzoni|arXiv (Cornell University)|Nov 10, 2014
Particle physics theoretical and experimental studiesPhysics and Astronomy1 references8 citations
TL;DR

The Fermilab E989 experiment aims to measure the muon anomalous magnetic moment with 0.14 ppm precision, achieving a fourfold improvement over the BNL E821 experiment. By reusing the BNL storage ring at Fermilab, employing advanced detectors, improved beam handling, and reduced systematic uncertainties, the experiment seeks to confirm or resolve the existing 3σ discrepancy between the Standard Model prediction and prior measurements, potentially revealing new physics beyond the Standard Model.

ABSTRACT

There is a long standing discrepancy between the Standard Model prediction for the muon g-2 and the value measured by the Brookhaven E821 Experiment. At present the discrepancy stands at about three standard deviations, with a comparable accuracy between experiment and theory. Two new proposals -- at Fermilab and J-PARC -- plan to improve the experimental uncertainty by a factor of 4, and it is expected that there will be a significant reduction in the uncertainty of the Standard Model prediction. I will review the status of the planned experiment at Fermilab, E989, which will analyse 21 times more muons than the BNL experiment and discuss how the systematic uncertainty will be reduced by a factor of 3 such that a precision of 0.14 ppm can be achieved.

Motivation & Objective

  • To resolve the long-standing 3σ discrepancy between the measured muon g-2 and the Standard Model prediction.
  • To improve experimental precision by a factor of four compared to the BNL E821 experiment.
  • To reduce systematic uncertainties by a factor of three through enhanced beam control and detector design.
  • To test for new physics beyond the Standard Model via a high-precision measurement of the muon's anomalous magnetic moment.
  • To simultaneously measure the muon electric dipole moment and test for CPT or Lorentz violation.

Proposed method

  • Reusing the BNL E821 storage ring magnet at Fermilab, reassembled in a new, stable, and temperature-controlled MC-1 building.
  • Using a high-intensity proton beam to produce pions, which decay into muons, with a superconducting inflector magnet injecting the muons into the storage ring.
  • Employing lead fluoride (PbF2) crystal electromagnetic calorimeters with silicon photomultiplier (SiPM) readout for precise energy and timing measurements.
  • Implementing in-vacuum straw drift tubes to track muons and support parallel measurements of the muon electric dipole moment.
  • Utilizing a modern waveform digitizer-based data acquisition system capable of both event-mode and integrating-mode analysis.
  • Applying improved magnetic field shimming and field measurement systems to reduce systematic uncertainty in the magnetic field by 50%.

Experimental results

Research questions

  • RQ1Can the 3σ discrepancy between the measured muon g-2 and the Standard Model prediction be confirmed with improved experimental precision?
  • RQ2To what extent can systematic uncertainties in the muon g-2 measurement be reduced through detector segmentation, beamline optimization, and field uniformity?
  • RQ3What is the impact of improved hadronic vacuum polarization and light-by-light scattering calculations on the theoretical prediction of aμ?
  • RQ4Can the same data simultaneously yield a new limit on the muon electric dipole moment?
  • RQ5Is there evidence for CPT or Lorentz violation in muon spin precession from the high-precision g-2 measurement?

Key findings

  • The E989 experiment at Fermilab is expected to achieve a precision of 0.14 ppm on the muon g-2 measurement, a fourfold improvement over the BNL E821 experiment's 0.54 ppm.
  • The experiment will analyze 21 times more muons than the BNL E821 experiment, significantly reducing statistical uncertainty.
  • Systematic uncertainty in the precession frequency measurement is expected to be reduced by a factor of three through reduced pion contamination, segmented detectors, and improved kicker performance.
  • Magnetic field uniformity will be enhanced via improved shimming, reducing the systematic error in the magnetic field by 50%.
  • The first physics data-taking is expected in early 2017, with the first critical milestone—cooling the superconducting coils and powering the storage ring—achieved by spring 2015.
  • The experiment will simultaneously provide a new limit on the muon electric dipole moment and a more stringent test for CPT or Lorentz violation in muon spin precession.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.