[Paper Review] The NIKA2 commissioning campaign: performance and first results
The NIKA2 instrument, a dual-band millimeter-wave camera using frequency-multiplexed kinetic inductance detectors cooled to 150 mK, was successfully commissioned at the IRAM 30 m telescope, achieving diffraction-limited resolution and background-limited sensitivity across 1.15 and 2.0 mm bands. Key results include stable performance of all subsystems, successful polarization mode operation, and confirmation of photometric and noise performance within requirements, paving the way for community use in 2017.
The New IRAM KID Array 2 (NIKA 2) is a dual-band camera operating with three frequency-multiplexed kilopixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK. NIKA 2 is designed to observe the intensity and polarisation of the sky at 1.15 and 2.0 mm wavelength from the IRAM 30 m telescope. The NIKA 2 instrument represents a huge step in performance as compared to the NIKA pathfinder instrument, which has already shown state-of-the-art detector and photometric performance. After the commissioning planned to be accomplished at the end of 2016, NIKA 2 will be an IRAM resident instrument for the next ten years or more. NIKA 2 should allow the astrophysical community to tackle a large number of open questions reaching from the role of the Galactic magnetic field in star formation to the discrepancy between cluster-based and CMB-based cosmology possibly induced by the unknown cluster physics. We present an overview of the commissioning phase together with some first results.
Motivation & Objective
- To develop and commission a next-generation millimeter-wave camera with dual-band, polarization, and high angular resolution for the IRAM 30 m telescope.
- To overcome limitations of existing bolometer arrays by deploying frequency-multiplexed Lumped Element Kinetic Inductance Detectors (LEKIDs) for scalable, high-multiplexing readout.
- To achieve background-limited sensitivity and diffraction-limited performance across 1.15 mm and 2.0 mm bands for deep continuum surveys.
- To validate instrument performance through a series of test runs and prepare for community use by 2017.
- To identify and mitigate systematic effects such as beam distortion and correlated noise to ensure photometric accuracy and stability.
Proposed method
- Deploy three frequency-multiplexed kilopixel arrays of LEKIDs cooled to 150 mK in a dilution refrigerator cryostat.
- Install the NIKA2 instrument at the foci of the IRAM 30 m telescope in October 2015, with optical components including dichroic beamsplitters and anti-reflection-coated lenses.
- Use NIKEL readout electronics to enable frequency-domain multiplexing of up to 20 feed-lines per array, with real-time data acquisition and calibration.
- Conduct systematic test runs from October 2015 to March 2016 to characterize beam patterns, noise equivalent flux density (NEFD), and polarization response.
- Perform photometric calibration using standard sources and map extended emission to assess sensitivity and dynamic range.
- Implement instrument upgrades in September 2016, including replacing the 2 mm array, adding dark pixels for noise monitoring, upgrading readout boards, and enhancing optical coatings.
Experimental results
Research questions
- RQ1Can a dual-band, polarization-sensitive, kilopixel-scale KID array achieve background-limited sensitivity at 1.15 and 2.0 mm from a ground-based telescope?
- RQ2How well do the beam patterns and beam shapes match diffraction-limited expectations, and what is the level of sidelobe contamination?
- RQ3To what extent do systematic effects such as focal plane distortion, correlated noise, and gain instability affect photometric accuracy and sensitivity?
- RQ4Can the instrument achieve the required NEFD of 15 mJy·s⁰.⁵/beam at 1.15 mm and 10 mJy·s⁰.⁵/beam at 2.0 mm across the full field of view?
- RQ5Is the polarization mode stable and accurate enough for astrophysical applications such as measuring the Sunyaev-Zel’dovich effect in high-redshift clusters?
Key findings
- All subsystems, including cryogenics, optics, and readout electronics, operated nominally during the first four test runs from October 2015 to March 2016.
- The beam morphology showed sidelobes compatible with those of the NIKA pathfinder, indicating consistent beam performance.
- Focal plane image distortions were found to be inhomogeneous across the three arrays, with localized variations requiring correction.
- Noise equivalent flux density (NEFD) measurements were consistent with requirements, with values of 15 mJy·s⁰.⁵/beam at 1.15 mm and 10 mJy·s⁰.⁵/beam at 2.0 mm.
- Polarization mode was successfully demonstrated, with first observations of quasars and extended polarized sources confirming functionality, though detailed analysis was deferred.
- Systematic effects such as low-level beam distortion and correlated noise were identified and targeted for mitigation through a planned instrument upgrade in September 2016.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.