[Paper Review] The RHIC Beam Energy Scan Phase II: Physics and Upgrades
This paper presents the physics program and technical upgrades for RHIC's Beam Energy Scan Phase II (BES-II), which aims to precisely map the QCD phase diagram at high baryon chemical potential by measuring net-proton kurtosis, directed flow, and dielectron spectra. Using electron cooling and detector upgrades—including the EPD and eTOF—BES-II achieves 10× higher statistics and improved kinematic coverage, enabling enhanced sensitivity to the QCD critical point and chiral symmetry restoration.
The exploration of the QCD phase diagram has been one of the main drivers of contemporary nuclear physics. The Relativistic Heavy Ion Collider (RHIC) at BNL is uniquely suited for this task through its Beam Energy Scan (BES) program which allowed for a large range in baryon chemical potential $μ_B$ as was successfully demonstrated after the completion of Phase 1 in 2014. Phase 2 of the BES at RHIC is scheduled to start in 2019 and will explore with precision measurements the intermediate-to-high $μ_B$ region of the QCD phase diagram, five energies $\sqrt{s_{NN}}$ from 7.7 to 19.6 GeV in collider mode and eight energies $\sqrt{s{_{NN}}}$ from 3.0 to 7.7 GeV in fixed-target mode. Some of the key measurements are: the net-protons kurtosis that could pinpoint the position of a critical point, the directed flow that might prove a softening of the EOS, and the chiral restoration in the dielectron channel. These measurements will be possible with an order of magnitude better statistics provided by the electron cooling upgrade of RHIC and with the detector upgrades planned to improve STAR's acceptance. These proceedings review the BES Phase-2 program and the physics opportunities enabled by these upgrades.
Motivation & Objective
- To precisely map the QCD phase diagram in the intermediate-to-high baryon chemical potential region ($\mu_B$) using the Beam Energy Scan Phase II at RHIC.
- To search for the QCD critical point through high-order fluctuations of net-proton and net-kaon multiplicity distributions, particularly kurtosis ($\kappa\sigma^2$).
- To probe the Equation of State (EoS) softening via directed flow measurements, which may signal a first-order phase transition.
- To study chiral symmetry restoration through dielectron spectra from vector meson decays ($\rho$, $\omega$, $\phi$) at low invariant mass.
- To extend the accessible $\mu_B$ range up to 720 MeV using fixed-target mode with improved luminosity and detector performance.
Proposed method
- Utilizes 5 collider energies ($\sqrt{s_{NN}}$ = 7.7–19.6 GeV) and 8 fixed-target energies ($\sqrt{s_{NN}}$ = 3.0–7.7 GeV) to explore a broad range of $\mu_B$.
- Employs electron cooling (LEReC) to increase luminosity by a factor of 4 at low energies and optimize beam quality for fixed-target operation.
- Introduces the Event Plane Detector (EPD) with $2.1 < |\eta| < 5$ coverage to improve event plane resolution by factors of 2–3, reducing systematics in flow measurements.
- Deploys the extended Time-of-Flight (eTOF) detector in $1.1 < \eta < 1.6$ to enhance particle identification in forward regions, especially for fixed-target data.
- Analyzes net-proton cumulant ratios ($\kappa\sigma^2$, $S\sigma$) as functions of total proton and anti-proton multiplicity to identify critical behavior near the critical point.
- Leverages STAR detector’s full mid-rapidity ($|y| < 1$) acceptance and $dE/dx$ + TOF particle identification to ensure high-precision, low-systematic measurements.
Experimental results
Research questions
- RQ1Where is the QCD critical point located in the $T$–$\mu_B$ plane, and can it be pinpointed via net-proton kurtosis fluctuations?
- RQ2Does the directed flow of net-protons exhibit non-monotonic behavior indicative of a softening of the Equation of State near a first-order phase transition?
- RQ3Can chiral symmetry restoration be observed through modifications in the dielectron spectrum at low invariant mass?
- RQ4How does the inclusion of forward-region event plane measurements (via EPD) reduce systematics in flow and fluctuation analyses?
- RQ5To what extent does the eTOF upgrade improve particle identification and extend the kinematic reach of fluctuation and flow measurements in fixed-target mode?
Key findings
- BES-II achieves approximately 10× higher statistics than BES-I, enabling meaningful measurements of dielectron spectra below $\sqrt{s_{NN}} = 19.6$ GeV for the first time.
- The net-proton $\kappa\sigma^2$ signal is expected to rise above unity near the critical point and drop below unity below it, providing a clear signature for critical behavior.
- The EPD upgrade improves event plane resolution by a factor of 2–3, significantly reducing systematics in directed flow and fluctuation measurements.
- The eTOF detector extends particle identification coverage to $\eta \approx 1.6$, enhancing the precision of $\kappa\sigma^2$ measurements as a function of total proton and anti-proton multiplicity.
- Fixed-target operation at $\sqrt{s_{NN}} = 3.0$–7.7 GeV extends $\mu_B$ to 720 MeV, enabling exploration of the high-$\mu_B$ regime previously inaccessible.
- STAR demonstrated in 2015 that fixed-target mode with 30 minutes of beam time could reproduce results from prior experiments (e.g., E895, E877), validating the feasibility of the BES-II fixed-target program.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.