Skip to main content
QUICK REVIEW

[Paper Review] Thick films coating a plate withdrawn from a bath

Jacco H. Snoeijer, J. Ziegler|ArXiv.org|Mar 27, 2008
Material Properties and ApplicationsMaterials Science7 citations
TL;DR

This paper proposes a theoretical and experimental analysis of thick viscous film coatings on plates withdrawn from a liquid bath, demonstrating that partially wetting fluids can form thick films with thickness scaling as $ U^{1/2} $, distinct from the classical Landau-Levich-Derjaguin (LLD) film scaling as $ U^{2/3} $. The key contribution is the identification of a continuous family of thick film solutions with a dimple at the film-bath interface, validated by excellent agreement between theory and experiment in a phase diagram of film thickness and capillary number.

ABSTRACT

We consider the deposition of a film of viscous liquid on a flat plate being withdrawn from a bath, experimentally and theoretically. For any plate speed $U$, there is a range of ``thick'' film solutions whose thickness scales like $U^{1/2}$ for small $U$. These solutions are realized for a partially wetting liquid, while for a perfectly wetting liquid the classical Landau-Levich-Derjaguin (LLD) film is observed, whose thickness scales like $U^{2/3}$. The thick film is distinguished from the LLD film by a dip in its spatial profile at the transition to the bath. We calculate the phase diagram for the existence of stationary film solutions as well as the film profiles, and find excellent agreement with experiment.

Motivation & Objective

  • To understand the formation of thick viscous films during dip coating of a plate from a liquid bath, particularly when the liquid is only partially wetting.
  • To identify and characterize a new class of stationary film solutions that differ from the classical Landau-Levich-Derjaguin (LLD) film by exhibiting a dimple at the film-bath interface.
  • To establish a phase diagram in the $(h_f, \text{Ca})$ parameter space that predicts the existence and stability of thick film solutions.
  • To explain the experimental realization of thick films through the dynamics of the contact line recession speed and flux continuity.
  • To validate theoretical predictions against high-resolution experimental measurements of film profiles and fluxes.

Proposed method

  • Theoretical analysis uses the lubrication approximation for free surface flows, governed by the equation $ \kappa' - 1 + \frac{3}{h^2}\left(\text{Ca} - \frac{q}{h}\right) = 0 $, where $ h(z) $ is film thickness, $ \kappa $ is curvature, $ q $ is flux, and $ \text{Ca} $ is the capillary number.
  • A similarity solution is derived near the dimple region: $ h = \text{Ca}^{2/3} H(\eta) $, with $ \eta = (z - z_d)/\text{Ca}^{1/3} $, to describe the balance between viscous and capillary forces.
  • The flux $ q $ is related to film thickness via $ q = h_f(\text{Ca} - h_f^2/3) $, which exhibits non-monotonic behavior due to gravitational drainage, enabling multiple thicknesses for the same flux.
  • Theoretical solutions are matched to the capillary meniscus of the bath in the small $ \text{Ca} $ limit, ensuring finite curvature at the dimple, consistent with experimental observations.
  • Experimental validation uses interferometry and wire imaging techniques with sub-pixel resolution to reconstruct film profiles, measuring local slope and integrating to obtain thickness with $ \sim 3\% $ uncertainty.
  • The phase diagram is constructed by comparing theoretical solutions with experimental data points across varying capillary numbers and film thicknesses, with error bars below symbol size.

Experimental results

Research questions

  • RQ1What are the conditions under which thick films—distinct from the classical LLD film—can form during dip coating of a partially wetting plate?
  • RQ2How does the film thickness scale with withdrawal speed $ U $, and how does this differ from the classical $ U^{2/3} $ scaling of the LLD film?
  • RQ3What is the role of gravitational drainage and flux continuity in enabling multiple stable film thicknesses for the same capillary number?
  • RQ4How is the dimple structure at the film-bath interface formed, and what physical balance governs its shape?
  • RQ5What experimental conditions allow the realization of thick film solutions, and how do they transition to LLD films?

Key findings

  • For partially wetting fluids, thick film solutions exist with thickness scaling as $ U^{1/2} $, in contrast to the classical LLD film scaling as $ U^{2/3} $, and these are experimentally observable.
  • The thick film solutions are characterized by a dimple at the film-bath interface, which results from a balance between viscous and capillary forces, and is absent in the LLD solution.
  • Theoretical predictions of the phase diagram in the $ (h_f, \text{Ca}) $ plane show excellent agreement with experimental data, with the thick film solutions occupying a continuous range in the grey region of Fig. 2.
  • The flux $ q $ through the dimple is limited, and this flux constraint provides a lower bound on the film thickness $ h_f $, with the upper bound defined by gravitational drainage causing $ q = 0 $.
  • Experimentally, thick films are most easily realized just above the critical capillary number $ \text{Ca}_f $, where the contact line recedes slowly, fixing $ h_f \approx (3\text{Ca}_f)^{1/2} $, and increasing $ \text{Ca} $ leads to a horizontal path in the phase diagram.
  • High-resolution interferometry and wire imaging techniques achieve sub-pixel resolution, enabling accurate reconstruction of film profiles with a reproducibility of $ \sim 1 $ nm for thick films and $ \sim 0.1 $ nm for LLD films.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.