Skip to main content
QUICK REVIEW

[Paper Review] Three-dimensional GRMHD Simulations of Rapidly Rotating Stellar Core-Collapse

S. Shibagaki, Takami Kuroda|arXiv (Cornell University)|Sep 10, 2023
Neutrino Physics ResearchPhysics and Astronomy5 citations
TL;DR

This study presents 3D general relativistic magnetohydrodynamic (GRMHD) simulations of a 20 M⊙ star's core collapse with spectral neutrino transport, focusing on gravitational wave (GW) signatures from magnetorotational (MR) explosion mechanisms. It finds that only models with initial magnetic fields of 10¹² G and rotation rates of 1–2 rad s⁻¹ produce MHD outflows, generating a monotonic GW amplitude rise perpendicular to the rotation axis, with neutrino-driven GWs exceeding matter-driven signals by over an order of magnitude due to anisotropic emission and memory effects, peaking below ∼10 Hz—highlighting the need for low-frequency detectors like DECIGO for future Galactic supernova detection.

ABSTRACT

We present results from fully general relativistic (GR), three-dimensional (3D), neutrino-radiation magneto-hydrodynamic (MHD) simulations of stellar core collapse of a 20 M$_\odot$ star with spectral neutrino transport. Our focus is to study the gravitational-wave (GW) signatures from the magnetorotationally (MR)-driven models. By parametrically changing the initial angular velocity and the strength of the magnetic fields in the core, we compute four models. Our results show that the MHD outflows are produced only for models (two out of four), to which magnetic field strengths of 10$^{12}$ G and rotation rates of 1 or 2 rad s$^{-1}$ are initially imposed in the core. Seen from the direction perpendicular to the rotational axis, a characteristic waveform is obtained exhibiting a monotonic time increase in the wave amplitude. As previously identified, this stems from the propagating MHD outflows along the axis. We show that the GW amplitude from anisotropic neutrino emission becomes more than one order-of-magnitude bigger than that from the matter contribution, whereas seen from the rotational axis, both of the two components are in the same order-of-magnitudes. Due to the memory effect, the frequency of the neutrino GW from our full-fledged 3D-MHD models is in the range less than $\sim$10 Hz. Toward the future GW detection for a Galactic core-collapse supernova, if driven by the MR mechanism, the planned next-generation detector as DECIGO is urgently needed to catch the low-frequency signals.

Motivation & Objective

  • To investigate gravitational wave (GW) signatures from magnetorotational (MR)-driven core-collapse supernovae in 3D general relativistic (GR) simulations.
  • To determine the conditions under which MHD outflows form and how they affect GW emission in rapidly rotating, magnetized stellar cores.
  • To quantify the relative contributions of matter and neutrino emission to GW signals, especially in the context of the Christodoulou-Epstein memory effect.
  • To assess the detectability of such low-frequency GW signals with next-generation detectors like DECIGO.
  • To explore the sensitivity of GW waveforms to initial core conditions, including magnetic field strength and angular velocity.

Proposed method

  • Conduct fully general relativistic (GR), three-dimensional (3D), neutrino-radiation magnetohydrodynamics (MHD) simulations of a 20 M⊙ star’s core collapse with spectral neutrino transport.
  • Parametrically vary initial core conditions: magnetic field strengths of 10¹² G and rotation rates of 1 or 2 rad s⁻¹ across four distinct models.
  • Use high-resolution numerical methods on supercomputers (Cray XC50 and XC40) to resolve complex MHD dynamics and neutrino transport.
  • Compute gravitational wave (GW) signals from both matter asymmetries and anisotropic neutrino emission using the Christodoulou-Epstein memory effect.
  • Analyze GW waveforms from multiple viewing angles, particularly perpendicular and along the rotational axis, to assess directional dependence.
  • Apply post-processing techniques to extract GW amplitudes and frequencies, focusing on the low-frequency regime (<10 Hz) due to memory effects.

Experimental results

Research questions

  • RQ1Under what initial magnetic field and rotation conditions do MHD outflows form in 3D GRMHD core-collapse simulations of a 20 M⊙ star?
  • RQ2How do the gravitational wave amplitudes from matter asymmetries compare to those from anisotropic neutrino emission in MR-driven core-collapse models?
  • RQ3What is the frequency range of gravitational waves generated by MHD outflows, and how does the Christodoulou-Epstein memory effect influence this?
  • RQ4Why is the neutrino-driven GW contribution significantly larger than the matter-driven contribution in certain viewing directions?
  • RQ5What implications do these results have for the detectability of core-collapse supernovae by next-generation low-frequency gravitational wave detectors like DECIGO?

Key findings

  • Only two out of four simulated models—those with initial magnetic fields of 10¹² G and rotation rates of 1 or 2 rad s⁻¹—produced MHD outflows.
  • From the direction perpendicular to the rotational axis, a characteristic GW waveform with a monotonic amplitude increase was observed, attributed to propagating MHD outflows along the axis.
  • The gravitational wave amplitude from anisotropic neutrino emission exceeded that from matter asymmetries by more than one order of magnitude in the equatorial viewing direction.
  • When viewed along the rotational axis, both matter and neutrino contributions to the GW amplitude were of the same order of magnitude.
  • The frequency of the neutrino-driven GW signal was found to be below ∼10 Hz due to the Christodoulou-Epstein memory effect, placing it in the low-frequency band.
  • The results imply that next-generation low-frequency gravitational wave detectors such as DECIGO are essential for detecting core-collapse supernovae driven by the magnetorotational mechanism.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.