Skip to main content
QUICK REVIEW

[Paper Review] Time Synchronization in modular collaborative robots

Carlos San Vicente Gutiérrez, Lander Usategui San Juan|arXiv (Cornell University)|Sep 19, 2018
Modular Robots and Swarm IntelligenceEngineering8 citations
TL;DR

This paper proposes M-cobots, a new class of modular collaborative robots that achieve sub-microsecond clock synchronization using IEEE 1588 Precision Time Protocol (PTP) over Time-Sensitive Networking (TSN). The system demonstrates 100 µs ROS 2.0 message timestamping accuracy and millisecond-level end-to-end latency even under 90% network load, enabling precise, vendor-agnostic synchronization for real-time robotic applications.

ABSTRACT

A new generation of robot systems which are modular, flexible and safe for human-robot interaction are needed. Existing cobots seem to meet only the later and require a modular approach to improve their reconfigurability and interoperability. We propose a new sub-class of cobots named M-cobots which tackle these problems. In particular, we discuss the relevance of synchronization for these systems, analyze it and demonstrate how with a properly configured M-cobot, we are able to obtain a) distributed sub-microsecond clock synchronization accuracy among modules, b) timestamping accuracy of ROS 2.0 messages under 100 microseconds and c) millisecond-level end-to-end communication latencies, even when disturbed with networking overloads of up to 90% of the network capacity.

Motivation & Objective

  • Address the lack of modularity, interoperability, and precise synchronization in existing collaborative robots (cobots).
  • Enable vendor-agnostic integration of robotic modules through native modularity and standardized time synchronization.
  • Overcome synchronization challenges in distributed robotic systems that degrade performance in motion control, sensor fusion, and real-time communication.
  • Demonstrate robust, low-latency communication in modular robotic systems under high network load conditions.
  • Establish a foundation for scalable, reconfigurable, and interoperable robotic systems using open standards like PTP and ROS 2.

Proposed method

  • Implement IEEE 1588 Precision Time Protocol (PTP) as the core synchronization mechanism across distributed robotic modules.
  • Integrate PTP with Time-Sensitive Networking (TSN) to ensure deterministic, low-jitter communication and precise timing distribution.
  • Utilize ROS 2.0's clock and time abstraction layer to achieve accurate message timestamping with minimal overhead.
  • Configure hardware and software stacks using Real-Time Linux and TSN-compliant network interfaces to support sub-microsecond synchronization.
  • Apply passive synchronization techniques to estimate and compensate for hardware and software-induced delays in sensor and actuator signals.
  • Evaluate system performance under controlled network overload (up to 90% capacity) to test robustness and latency stability.

Experimental results

Research questions

  • RQ1Can a modular collaborative robot architecture achieve sub-microsecond clock synchronization across distributed modules using open standards?
  • RQ2To what extent does PTP-based synchronization improve ROS 2.0 message timestamping accuracy in a distributed robotic system?
  • RQ3How does network congestion affect end-to-end communication latency in a modular robotic system with PTP synchronization?
  • RQ4Can the proposed system maintain millisecond-level end-to-end latency under high network load (up to 90%)?
  • RQ5What is the impact of hardware and software delay compensation on synchronization accuracy and system performance?

Key findings

  • The M-cobot system achieves distributed clock synchronization with sub-microsecond accuracy across all modules using IEEE 1588 PTP over TSN.
  • ROS 2.0 message timestamping accuracy is maintained within 100 microseconds, enabling precise temporal correlation of sensor and control data.
  • End-to-end communication latency remains at the millisecond level even when network utilization reaches 90%, demonstrating high resilience to congestion.
  • The system successfully mitigates the impact of network overload through proper configuration of PTP and TSN, preserving real-time performance.
  • Synchronization accuracy is robust across diverse robotic tasks, including motion control and sensor fusion, where timing precision is critical.
  • The integration of PTP with ROS 2 and TSN enables a vendor-agnostic, interoperable, and reconfigurable robotic architecture suitable for industrial applications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.