TL;DR

This paper proposes a contrast-agnostic deep learning method for soft spinal cord segmentation using multi-contrast MRI data, generating participant-specific soft ground truth via averaging across six contrasts and training a UNet with a regression loss. The approach reduces cross-contrast CSA variability and generalizes better than contrast-specific models across vendors, contrasts, and pathologies, while accounting for partial volume effects.

ABSTRACT

Spinal cord segmentation is clinically relevant and is notably used to compute spinal cord cross-sectional area (CSA) for the diagnosis and monitoring of cord compression or neurodegenerative diseases such as multiple sclerosis. While several semi and automatic methods exist, one key limitation remains: the segmentation depends on the MRI contrast, resulting in different CSA across contrasts. This is partly due to the varying appearance of the boundary between the spinal cord and the cerebrospinal fluid that depends on the sequence and acquisition parameters. This contrast-sensitive CSA adds variability in multi-center studies where protocols can vary, reducing the sensitivity to detect subtle atrophies. Moreover, existing methods enhance the CSA variability by training one model per contrast, while also producing binary masks that do not account for partial volume effects. In this work, we present a deep learning-based method that produces soft segmentations of the spinal cord. Using the Spine Generic Public Database of healthy participants ($ ext{n}=267$; $ ext{contrasts}=6$), we first generated participant-wise soft ground truth (GT) by averaging the binary segmentations across all 6 contrasts. These soft GT, along with aggressive data augmentation and a regression-based loss function, were used to train a U-Net model for spinal cord segmentation. We evaluated our model against state-of-the-art methods and performed ablation studies involving different loss functions and domain generalization methods. Our results show that using the soft segmentations along with a regression loss function reduces CSA variability ($p < 0.05$, Wilcoxon signed-rank test). The proposed spinal cord segmentation model generalizes better than the state-of-the-art methods amongst unseen datasets, vendors, contrasts, and pathologies (compression, lesions), while accounting for partial volume effects.

Motivation & Objective

  • To address the variability in spinal cord cross-sectional area (CSA) measurements caused by MRI contrast dependency in existing segmentation methods.
  • To reduce inter-contrast CSA variability by training a single model on soft ground truth derived from multiple contrasts.
  • To improve generalization across unseen MRI vendors, contrasts, and pathologies (e.g., lesions, compression) by leveraging diverse training data.
  • To account for partial volume effects through soft segmentation, avoiding binary masks that ignore tissue boundary uncertainty.
  • To develop a foundational model for robust, multi-contrast spinal cord morphometry in clinical and multi-center studies.

Proposed method

  • Generated participant-wise soft ground truth by averaging binary segmentations across six MRI contrasts (T1w, T2w, T2w-SPACE, T2w-TSE, T2w-TSE-SPACE, T2w-TSE-SPACE-3D) from the Spine Generic Public Database (n=267).
  • Applied aggressive data augmentation (rotation, flipping, scaling, intensity jittering) to increase model robustness and generalization.
  • Trained a UNet-based deep learning model using a regression-based loss function to predict soft segmentation masks instead of binary masks.
  • Used a center-cropping strategy during preprocessing, assuming spinal cord is centrally located, with a configurable flag for edge cases (e.g., scoliosis, lumbar spine).
  • Evaluated performance using Wilcoxon signed-rank tests for CSA variability and compared against state-of-the-art contrast-specific models (e.g., soft_per_contrast T2w, DeepSeg2D).
  • Conducted ablation studies varying ground truth types, loss functions, and contrast-specific models to isolate contributions of soft GT and regression loss.
Figure 1: Preprocessing pipeline for soft average segmentations ground truth. (1) Automatic hard spinal cord segmentation using sct_deepseg_sc & manual corrections; (2) Registration to T2w space; (3) Applying each contrast’s warping field to bring the segmentation masks to the T2w space; (4) Averagi
Figure 1: Preprocessing pipeline for soft average segmentations ground truth. (1) Automatic hard spinal cord segmentation using sct_deepseg_sc & manual corrections; (2) Registration to T2w space; (3) Applying each contrast’s warping field to bring the segmentation masks to the T2w space; (4) Averagi

Experimental results

Research questions

  • RQ1Can soft ground truth generated from multiple contrasts reduce CSA variability across MRI sequences?
  • RQ2Does a regression-based loss function improve generalization across unseen MRI contrasts and vendors compared to binary cross-entropy loss?
  • RQ3Can a single deep learning model trained on multi-contrast data generalize to unseen pathologies such as lesions and spinal cord compression?
  • RQ4To what extent does soft segmentation mitigate partial volume effects compared to binary segmentation?
  • RQ5How does the proposed method compare to contrast-specific models in terms of CSA consistency and generalization performance?

Key findings

  • The proposed model with soft ground truth and regression loss significantly reduced CSA variability across all six contrasts (p < 0.05, Wilcoxon signed-rank test).
  • The model generalized better than state-of-the-art contrast-specific methods across unseen datasets, vendors, contrasts, and pathologies, including lesions and spinal cord compression.
  • Soft segmentation improved boundary delineation, especially in the presence of lesions, compared to models trained on single contrasts.
  • Ablation studies confirmed that soft ground truth and regression loss were key contributors to reduced CSA variability and improved generalization.
  • The model demonstrated robust performance on unseen contrasts and pathologies, suggesting strong zero-shot generalization potential.
  • The method shows promise for increasing sensitivity in detecting subtle spinal cord atrophy by minimizing contrast-induced morphometric bias.
Figure 2: Architecture of the proposed SoftSeg model.