TL;DR

This paper proposes a transfer learning framework using a pre-trained LeNet-5 CNN to diagnose faults and estimate fault locations in transmission lines of varying lengths, without requiring extensive retraining. By transferring knowledge from a source model trained on 100 km lines to target models for different line lengths, the method reduces training time by up to fourfold while maintaining classification accuracy and location estimation error comparable to dedicated models.

ABSTRACT

Recent artificial intelligence-based methods have shown great promise in the use of neural networks for real-time sensing and detection of transmission line faults and estimation of their locations. The expansion of power systems including transmission lines with various lengths have made a fault detection, classification, and location estimation process more challenging. Transmission line datasets are stream data which are continuously collected by various sensors and hence, require generalized and fast fault diagnosis approaches. Newly collected datasets including voltages and currents might not have enough and accurate labels (fault and no fault) that are useful to train neural networks. In this paper, a novel transfer learning framework based on a pre-trained LeNet-5 convolutional neural network is proposed. This method is able to diagnose faults for different transmission line lengths and impedances by transferring the knowledge from a source convolutional neural network to predict a dissimilar target dataset. By transferring this knowledge, faults from various transmission lines, without having enough labels, can be diagnosed faster and more efficiently compared to the existing methods. To prove the feasibility and effectiveness of this methodology, seven different datasets that include various lengths of transmission lines are used. The robustness of the proposed methodology against generator voltage fluctuation, variation in fault distance, fault inception angle, fault resistance, and phase difference between the two generators are well shown, thus proving its practical values in the fault diagnosis of transmission lines.

Motivation & Objective

  • Address the challenge of diagnosing faults in transmission lines of varying lengths and impedances with limited labeled data.
  • Reduce training time and computational cost for fault diagnosis in stream-based, real-time power system data.
  • Develop a generalized deep learning model that is reusable across different transmission line configurations without full retraining.
  • Improve robustness to variations in fault inception angle, resistance, generator voltage, and phase difference between generators.
  • Demonstrate the feasibility of transfer learning for fault diagnosis in high-volatility, stream-based power system data.

Proposed method

  • Pre-train a LeNet-5 convolutional neural network on a source dataset of 100 km transmission lines with labeled fault data.
  • Freeze the feature extraction layers of the pre-trained model to preserve learned representations.
  • Transfer the frozen feature extractor to a new CNN architecture tailored for a target transmission line length.
  • Retrain only the fully connected layers of the target network using labeled data specific to the new line length.
  • Apply fine-tuning to further improve performance on the target dataset, minimizing error while reducing training time.
  • Use voltage and current signals as input, processed through time-series image conversion for CNN input compatibility.

Experimental results

Research questions

  • RQ1Can transfer learning reduce training time for fault diagnosis in transmission lines of varying lengths without sacrificing accuracy?
  • RQ2How does the performance of transfer learning compare to training a dedicated CNN from scratch for different line lengths?
  • RQ3To what extent does the method remain robust under variations in fault resistance, inception angle, generator voltage, and phase difference?
  • RQ4How does the performance degrade as the source and target line lengths diverge?
  • RQ5Can the method achieve real-time inference speed meeting IEEE standards for fault location estimation?

Key findings

  • The transfer learning-based method reduced training time for fault location estimation to less than one-fourth of that required by a dedicated CNN, achieving a 75% reduction in training time.
  • For all line lengths tested (12.5 km to 800 km), the mean squared error (MSE) of fault location estimation was within 0.1 m² of the dedicated CNN baseline, with the best performance at 6.79×10⁻² m² for 400 km lines.
  • The cumulative test time for fault detection, classification, and location estimation was under 6 μs, satisfying IEEE standard requirements for real-time applications.
  • Fine-tuning reduced the MSE by over 50% compared to the non-fine-tuned transfer learning approach, demonstrating its effectiveness in improving accuracy.
  • The method maintained high accuracy across all tested variations, including fault resistance, inception angle, and generator voltage fluctuations, proving robustness.
  • As the difference between source and target line lengths increased, the MSE increased slightly, confirming expected feature distribution shifts, but performance remained acceptable across all lengths.