Skip to main content
QUICK REVIEW

[Paper Review] Real-time Faulted Line Localization and PMU Placement in Power Systems through Convolutional Neural Networks

Wenting Li, Deepjyoti Deka|arXiv (Cornell University)|Oct 11, 2018
Power Systems Fault DetectionEngineering35 references4 citations
TL;DR

This paper proposes a convolutional neural network (CNN)-based method for real-time faulted line localization in power systems using physically interpretable voltage features derived from substitution theory. The approach achieves high accuracy even at 7% bus observability and outperforms other machine learning methods, while a joint PMU placement strategy further enhances performance under limited measurements.

ABSTRACT

Diverse fault types, fast re-closures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as static loads, or require much higher sampling rates or total measurement availability. This paper proposes a faulted line localization method based on a Convolutional Neural Network (CNN) classifier using bus voltages. Unlike prior data-driven methods, the proposed classifier is based on features with physical interpretations that improve the robustness of the location performance. The accuracy of our CNN based localization tool is demonstrably superior to other machine learning classifiers in the literature. To further improve the location performance, a joint phasor measurement units (PMU) placement strategy is proposed and validated against other methods. A significant aspect of our methodology is that under very low observability (7% of buses), the algorithm is still able to localize the faulted line to a small neighborhood with high probability. The performance of our scheme is validated through simulations of faults of various types in the IEEE 39-bus and 68-bus power systems under varying uncertain conditions, system observability, and measurement quality.

Motivation & Objective

  • To address the challenge of real-time faulted line localization in large-scale power systems with limited PMU measurements.
  • To improve robustness against measurement noise, time delays, load fluctuations, and varying fault types.
  • To develop a physically interpretable feature set that enhances model generalization and interpretability.
  • To design an optimal PMU placement strategy that jointly improves fault localization accuracy.
  • To validate the method on IEEE 39-bus and 68-bus systems under diverse fault conditions and low observability.

Proposed method

  • The method uses bus voltage measurements to construct a feature vector based on substitution theory, providing physical interpretability.
  • A 1D-CNN classifier is trained on these features to identify the faulted line from candidate lines.
  • The feature vector captures transient voltage variations with clear physical meaning, reducing reliance on high-frequency sampling.
  • A joint PMU placement algorithm is formulated to maximize fault localization accuracy under budget and observability constraints.
  • The CNN is trained on synthetically generated fault data with varying noise, delays, and load conditions to ensure robustness.
  • Performance is evaluated using the Line Accuracy Rate (LAR), with comparisons to baseline methods under low observability (7–30% buses measured).

Experimental results

Research questions

  • RQ1Can a data-driven CNN model achieve high faulted line localization accuracy with minimal PMU measurements?
  • RQ2How does the use of physically interpretable features improve robustness to noise, delays, and load variations?
  • RQ3To what extent does joint PMU placement enhance localization performance compared to random or topology-based strategies?
  • RQ4How does the method perform under low system observability (e.g., 7%) and realistic measurement delays?
  • RQ5Can the model maintain high accuracy across diverse fault types and clearing times?

Key findings

  • The proposed CNN-based method achieves over 95% Line Accuracy Rate (LAR) even at 7% bus observability, significantly outperforming other machine learning classifiers.
  • With 30% bus observability, the method maintains LAR above 98% across all fault types, including TP, LG, DLG, and LL.
  • Measurement delays up to 40 ms cause less than 5% degradation in LAR, with only 1% error when delay is 20 ms, demonstrating robustness.
  • Fault clearing times between 0.05s and 0.2s result in less than 2% LAR degradation, indicating resilience to varying clearing durations.
  • The joint PMU placement strategy outperforms random and topology-based methods, especially under low observability.
  • Misclassified lines are mostly geographically close to the true faulted line, indicating spatial consistency in predictions.