Skip to main content
QUICK REVIEW

[Paper Review] Transformer Architectures for Respiratory Sound Analysis and Multimodal Diagnosis

Theodore Aptekarev, Vladimir Sokolovsky|arXiv (Cornell University)|Jan 20, 2026
Phonocardiography and Auscultation TechniquesMedicine0 citations
TL;DR

The paper adapts Audio Spectrogram Transformer (AST) for asthma screening from respiratory sounds and evaluates a multimodal Vision-Language Model (VLM) that incorporates structured patient metadata, reporting high accuracy and comparable multimodal performance.

ABSTRACT

Respiratory sound analysis is a crucial tool for screening asthma and other pulmonary pathologies, yet traditional auscultation remains subjective and experience-dependent. Our prior research established a CNN baseline using DenseNet201, which demonstrated high sensitivity in classifying respiratory sounds. In this work, we (i) adapt the Audio Spectrogram Transformer (AST) for respiratory sound analysis and (ii) evaluate a multimodal Vision-Language Model (VLM) that integrates spectrograms with structured patient metadata. AST is initialized from publicly available weights and fine-tuned on a medical dataset containing hundreds of recordings per diagnosis. The VLM experiment uses a compact Moondream-type model that processes spectrogram images alongside a structured text prompt (sex, age, recording site) to output a JSON-formatted diagnosis. Results indicate that AST achieves approximately 97% accuracy with an F1-score around 97% and ROC AUC of 0.98 for asthma detection, significantly outperforming both the internal CNN baseline and typical external benchmarks. The VLM reaches 86-87% accuracy, performing comparably to the CNN baseline while demonstrating the capability to integrate clinical context into the inference process. These results confirm the effectiveness of self-attention for acoustic screening and highlight the potential of multimodal architectures for holistic diagnostic tools.

Motivation & Objective

  • Assess whether transformer-based architectures improve asthma screening from respiratory sounds beyond a CNN baseline.
  • Adapt the Audio Spectrogram Transformer (AST) for medical respiratory data and fine-tune on a dataset with hundreds of recordings per class.
  • Evaluate a multimodal Vision-Language Model (VLM) that fuses spectrograms with structured patient metadata for diagnosis.

Proposed method

  • Fine-tune a pre-trained Audio Spectrogram Transformer (AST) on a medical respiratory sound dataset with 1,613 recordings across asthma, healthy, and other pathologies.
  • Use mel-spectrogram inputs converted to 3-channel RGB-like images from multiple window sizes for AST.
  • Compare AST against a DenseNet201 CNN baseline on the same data splits.
  • Develop a Moondream-type Vision-Language Model (VLM) that accepts spectrogram-derived images plus structured metadata and an instruction prompt to output a JSON diagnosis.
  • Fine-tune the VLM with Low-Rank Adaptation (LoRA) adapters, keeping core weights frozen, and train a final classifier head.
  • Evaluate input durations of 5s and 10s, selecting 5s for final evaluation.

Experimental results

Research questions

  • RQ1Can AST provide higher accuracy than CNN baselines for asthma screening from respiratory sounds?
  • RQ2Does a multimodal VLM that combines spectrograms with structured metadata improve diagnostic performance or offer competitive results with traditional CNNs?
  • RQ3How does incorporating clinical context (age, sex, recording site) affect asthma classification in a multimodal setup?
  • RQ4What is the practical inference efficiency of AST and VLM on CPU/GPU for clinical deployment?

Key findings

  • AST achieved ~97% accuracy, ~97% F1, and ROC AUC of 0.98 for Asthma vs Not Asthma, outperforming the CNN baseline.
  • VLM achieved ~86-87% accuracy for Asthma vs Not Asthma, comparable to the DenseNet baseline in Youden index.
  • Ablation showed removing metadata causes severe performance degradation; text conditioning is essential for stable VLM inference.
  • AST performs well with 5-second clips, matching performance with 10-second clips while increasing training sample size.
  • DenseNet baseline accuracy ~87% with sensitivity ~93% and specificity ~82-86% on the same task, serving as a reference point.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.