Skip to main content
QUICK REVIEW

[Paper Review] TransFusion: Multi-view Divergent Fusion for Medical Image Segmentation with Transformers

Di Liu, Yunhe Gao|arXiv (Cornell University)|Mar 21, 2022
Medical Image Segmentation TechniquesComputer Science4 citations
TL;DR

TransFusion proposes a novel Transformer-based architecture for multi-view medical image segmentation that uses Divergent Fusion Attention (DiFA) and Multi-Scale Attention (MSA) to model long-range cross-view and cross-scale dependencies in unaligned cardiac MRI scans. It achieves state-of-the-art performance on the M&Ms-2 challenge, outperforming existing methods in both short-axis and long-axis right ventricle segmentation with Dice scores up to 89.78% and HD of 8.02mm.

ABSTRACT

Combining information from multi-view images is crucial to improve the performance and robustness of automated methods for disease diagnosis. However, due to the non-alignment characteristics of multi-view images, building correlation and data fusion across views largely remain an open problem. In this study, we present TransFusion, a Transformer-based architecture to merge divergent multi-view imaging information using convolutional layers and powerful attention mechanisms. In particular, the Divergent Fusion Attention (DiFA) module is proposed for rich cross-view context modeling and semantic dependency mining, addressing the critical issue of capturing long-range correlations between unaligned data from different image views. We further propose the Multi-Scale Attention (MSA) to collect global correspondence of multi-scale feature representations. We evaluate TransFusion on the Multi-Disease, Multi-View \& Multi-Center Right Ventricular Segmentation in Cardiac MRI (M\&Ms-2) challenge cohort. TransFusion demonstrates leading performance against the state-of-the-art methods and opens up new perspectives for multi-view imaging integration towards robust medical image segmentation.

Motivation & Objective

  • To address the challenge of fusing unaligned, multi-view medical images—particularly short-axis and long-axis cardiac MRI—for improved segmentation.
  • To model long-range cross-view and cross-scale dependencies in heterogeneous imaging data where traditional convolutional fusion fails.
  • To develop a unified framework that enables robust, attention-driven feature alignment across divergent views and scales.
  • To demonstrate the effectiveness of Transformer-based fusion in multi-center, multi-disease cardiac MRI segmentation tasks.

Proposed method

  • Introduces the Divergent Fusion Attention (DiFA) module to explicitly model cross-view context and semantic dependencies between unaligned image features.
  • Employs Multi-Scale Attention (MSA) to aggregate global correspondence across multi-scale feature representations in a pyramidal network architecture.
  • Uses a hybrid 3D + 2D backbone (3D and 2D UTNet) to process short-axis and long-axis cMRI inputs separately before fusion.
  • Applies DiFA and MSA blocks at multiple encoder levels to progressively refine cross-view and cross-scale feature representations.
  • Utilizes a hybrid 2.5D + 3D + 2D network mode to enhance spatial alignment and context modeling between views.
  • Employs a U-Net-style decoder with skip connections that incorporate fused features from DiFA and MSA modules at different scales.

Experimental results

Research questions

  • RQ1Can a Transformer-based architecture effectively model long-range dependencies across unaligned multi-view medical images?
  • RQ2How does the Divergent Fusion Attention (DiFA) module improve cross-view feature alignment and semantic consistency compared to standard attention or concatenation?
  • RQ3What is the optimal placement and number of DiFA modules across the network depth for maximizing segmentation performance?
  • RQ4How does the proposed multi-view fusion strategy compare to single-view or simple concatenation-based fusion in terms of robustness and accuracy?
  • RQ5To what extent does the hybrid 3D + 2D network mode enhance feature alignment and segmentation performance on multi-view cardiac MRI?

Key findings

  • TransFusion achieves a Dice score of 89.78% on the right ventricle segmentation task, significantly outperforming the next best method (rDLA*) at 86.49%.
  • The model achieves a mean Hausdorff distance (HD) of 8.02mm, the lowest among all compared methods, indicating superior boundary accuracy.
  • Ablation studies show that placing DiFA modules at higher encoder levels (e.g., levels 4 and 5) yields the most consistent performance gains, with diminishing returns beyond level 4.
  • The hybrid 3D + 2D network mode outperforms both 2.5D and single-view baselines, demonstrating the importance of spatial alignment across views.
  • When applied to existing models like UTNet and MCTrans, the DiFA module consistently improves performance, proving its generalizability and effectiveness.
  • The proposed method is the first to apply Transformers to multi-view medical image segmentation with explicit cross-view attention, opening new avenues for unaligned or multi-modality data fusion.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.