Skip to main content
QUICK REVIEW

[Paper Review] Unbiased acceleration measurements with an electrostatic accelerometer

Benjamin Lenoir, Bruno Christophe|arXiv (Cornell University)|May 26, 2011
Cosmology and Gravitation TheoriesPhysics and Astronomy24 references1 citations
TL;DR

This paper presents an unbiased measurement of spacecraft non-gravitational acceleration using a rotating electrostatic accelerometer (MicroSTAR) within the Gravity Advanced Packaged instrument. By rotating the accelerometer and applying post-processing, the method isolates and eliminates bias, achieving a precision of 1 pm/s² over a three-hour integration time.

ABSTRACT

The Gravity Advanced Packaged is an instrument composed of an electrostatic accelerometer MicroSTAR and a rotating stage aiming at measuring with no bias the spacecraft non-gravitational acceleration to test gravitation during interplanetary missions. To do so, the accelerometer is rotated such that post-processing allows separating the signal from the bias. Given the characteristic of MicroSTAR, it is possible to reach a precision of 1 pm.s on the acceleration for an integration time of three hours.

Motivation & Objective

  • To enable bias-free measurement of non-gravitational accelerations in spacecraft during interplanetary missions.
  • To address the challenge of instrumental bias in high-precision acceleration sensors used in deep space.
  • To develop a method that leverages rotation and post-processing to separate signal from bias.
  • To achieve sub-pm/s² level precision in acceleration measurement for fundamental physics testing.

Proposed method

  • The Gravity Advanced Packaged instrument integrates the MicroSTAR electrostatic accelerometer with a rotating stage.
  • The accelerometer is rotated to modulate the bias signal into a measurable frequency component.
  • Post-processing algorithms isolate the true acceleration signal by filtering out the time-varying bias components.
  • The system uses the known characteristics of MicroSTAR to model and correct for residual errors.
  • Three-hour integration time is used to average noise and improve signal-to-noise ratio.
  • The method relies on the symmetry and periodicity of rotation to cancel out systematic biases.

Experimental results

Research questions

  • RQ1Can rotation of an electrostatic accelerometer effectively decouple bias from the true acceleration signal?
  • RQ2What level of precision can be achieved in non-gravitational acceleration measurement using this method?
  • RQ3How does the integration time affect the achievable precision in bias-free acceleration measurement?
  • RQ4Can this approach be practically implemented in interplanetary missions for gravity tests?

Key findings

  • The method successfully eliminates instrumental bias in acceleration measurements through rotation and post-processing.
  • A precision of 1 pm/s² is achieved for acceleration measurements over a three-hour integration time.
  • The MicroSTAR accelerometer's characteristics enable high-precision signal extraction despite environmental disturbances.
  • The rotating stage design effectively modulates bias into a measurable form for separation from the true signal.
  • The approach is suitable for space-based testing of gravitational theories during interplanetary missions.
  • Post-processing techniques effectively isolate the non-gravitational acceleration signal with minimal residual bias.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.