Skip to main content
QUICK REVIEW

[Paper Review] UNet#: A UNet-like Redesigning Skip Connections for Medical Image Segmentation

Ledan Qian, Xiaofang Zhou|arXiv (Cornell University)|May 24, 2022
Radiomics and Machine Learning in Medical ImagingMedicine9 citations
TL;DR

This paper proposes UNet#—a novel UNet-like architecture that combines dense and full-scale skip connections to enhance feature aggregation across multi-scale features, improving organ and lesion boundary segmentation. By integrating deep supervision for model pruning and classification-guided modules to reduce false positives, UNet# achieves state-of-the-art performance on multiple 2D and 3D medical image segmentation benchmarks.

ABSTRACT

As an essential prerequisite for developing a medical intelligent assistant system, medical image segmentation has received extensive research and concentration from the neural network community. A series of UNet-like networks with encoder-decoder architecture has achieved extraordinary success, in which UNet2+ and UNet3+ redesign skip connections, respectively proposing dense skip connection and full-scale skip connection and dramatically improving compared with UNet in medical image segmentation. However, UNet2+ lacks sufficient information explored from the full scale, which will affect the learning of organs' location and boundary. Although UNet3+ can obtain the full-scale aggregation feature map, owing to the small number of neurons in the structure, it does not satisfy the segmentation of tiny objects when the number of samples is small. This paper proposes a novel network structure combining dense skip connections and full-scale skip connections, named UNet-sharp (UNet\#) for its shape similar to symbol \#. The proposed UNet\# can aggregate feature maps of different scales in the decoder sub-network and capture fine-grained details and coarse-grained semantics from the full scale, which benefits learning the exact location and accurately segmenting the boundary of organs or lesions. We perform deep supervision for model pruning to speed up testing and make it possible for the model to run on mobile devices; furthermore, designing two classification-guided modules to reduce false positives achieves more accurate segmentation results. Various experiments of semantic segmentation and instance segmentation on different modalities (EM, CT, MRI) and dimensions (2D, 3D) datasets, including the nuclei, brain tumor, liver, and lung, demonstrate that the proposed method outperforms state-of-the-art models.

Motivation & Objective

  • Address the limitations of UNet2+ in capturing full-scale contextual information and UNet3+ in handling small objects with limited training data.
  • Design a unified architecture that leverages both dense and full-scale skip connections to enhance feature fusion across semantic levels.
  • Enable efficient inference through deep supervision-based model pruning for deployment on mobile devices.
  • Reduce false positives in segmentation using classification-guided modules to improve boundary accuracy.

Proposed method

  • Introduce a novel UNet# architecture with a #-shaped structure that combines dense skip connections and full-scale skip connections for multi-scale feature aggregation.
  • Implement deep supervision across eight decoder branches, including the final output and four intermediate layers, to enable hierarchical representation learning and model pruning.
  • Apply pruning via magnitude-based magnitude pruning on the deep supervision branches, reducing model parameters while preserving performance.
  • Integrate two classification-guided modules (CGM) at different stages to suppress over-segmentation and false positives by refining decision boundaries.
  • Use multi-scale supervision with ground truth at different resolutions to guide feature learning at all levels of the decoder.
  • Train the model using cross-entropy and dice loss on both segmentation and classification heads to optimize for both localization and class discrimination.

Experimental results

Research questions

  • RQ1Can a hybrid skip connection design combining dense and full-scale connections improve feature representation in medical image segmentation?
  • RQ2Does deep supervision across multiple decoder branches enable effective model pruning without performance degradation?
  • RQ3Can classification-guided modules reduce false positives and improve boundary accuracy in organ and lesion segmentation?
  • RQ4How does UNet# compare to state-of-the-art models across diverse medical imaging modalities and dimensions?

Key findings

  • UNet# achieved a Dice score of 95.60% and IoU of 91.68% on the BraTs19 dataset, outperforming all compared SOTA models.
  • With the classification-guided module (CGM), UNet# achieved a Dice score of 96.14% and IoU of 92.08% on BraTs19, representing a 0.54% and 0.4% improvement over the base model.
  • On the Lits17 dataset, UNet# achieved 97.29% Dice and 94.79% IoU, surpassing all baselines including TransUNet and AttnUNet.
  • The CGM module further improved performance by 0.95% in Dice and 0.52% in IoU on Lits17, confirming its effectiveness in reducing false positives.
  • Model pruning via deep supervision reduced parameters by up to 97× (from 9.71M to 0.1M) while maintaining strong inference accuracy.
  • The pruned L¹ model (0.1M parameters) achieved 88.5% IoU on DSB2018, demonstrating feasibility for mobile deployment.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.